Dosimetry is a field of increasing importance in diagnostic radiology. There has been a realization among healthcare professionals that the dose of radiation received by patients via modern medical X-ray examinations could induce acute damage to the skin and eyes. The present study highlights the synthesis of polyvinyl alcohol/nitro blue tetrazolium nanocomposite films (PVA/NBT) for radiation detection depending on chromic, optical, chemical and morphologic changes. First, we synthesized the nanocomposite film-based PVA doped with NBT and the different parameters of the preparation procedure were optimized. Then The films were exposed to different low X-ray doses on the scale of mGy level (0, 2, 4, 10 and 20 mGy). The sensitivity and the performance of the made composite films were evaluated via different characterization methods. Indeed, the response curve based on UV-Vis absorptions revealed a linear increase in absorbance with increased radiation doses (R = 0.998). FTIR analysis showed a clear chemical modification in recorded spectra after irradiation. X-ray diffraction assessment revealed clear structural changes in crystallinity after ionization treatment. SEM analysis showed a clear morphological modification of PVA/NBT films after irradiation. In addition, the prepared PVA/NBT films exhibited excellent pre- and post-irradiation stability in dark and light. Finally, the quantitative colorimetry study confirmed the performance of the prepared films and the different colorimetric coordinates, the total color difference (∆E) and the color strength (K/S) showed a linear increase with increasing X-ray doses. The made nanocomposite PVA/NBT film might offer promising potential for an effective highly sensitive medical dosimeter applied for very low doses in X-ray diagnostic radiology.
1 October 2016 in Journal of Radiation Research and Applied Sciences
It is important to measure the radionuclide concentrations in red soil to determine the health effect and to protect the environment. The red soil regions located in Qassim province, Saudi Arabia were determined. Thirty red soil samples were collected from three regions (Al Bi'ithah, Dremeha and Al Bukaireyah). Gamma-ray spectrometry using NaI (Tl) detector was used to measure the radionuclides of 226Ra, 232Th and 40K. The average (range) of activity concentration of 226Ra was 10.0 (9.3–11.6) Bq/kg, 7.3 (6.6–8.4) Bq/kg and 19.4 (15.9–22.7) Bq/kg in Al Bi'ithah, Dremeha and Al Bukaireyah, respectively. For 232Th, the average values of radioactivity concentration were 11.8 (7.6–13.0), 6.3 (5.1–7.3) and 19.1 (17.8–20.7) in Al Bi'ithah, Dremeha and Al Bukaireyah, respectively. In addition, the average radionuclide concentration of 40K was 74.5 (71.2–78.3), 67.3 (57.6–77.4) and 94.3 (59.6–101.6) in Al Bi'ithah, Dremeha and Al Bukaireyah, respectively. Next, the comparison between radionuclide concentrations in this study and other published papers in the world was done. In addition, radiation hazard parameters were estimated. The maximum values of the radium equivalent and absorbed dose rate were 63.6 Bq/kg and 30.0 nGy/h, respectively. These values are lower than the international limit (370 Bq/kg and 65 nGy/h). Furthermore, the annual effective gamma doses and the lifetime hazards of cancer were lower than the international limit. The external hazard index (Hex), internal hazard index (Hin) and representative level index (Iγr) were found to be less than the acceptable limit of unity. Therefore, the study area is still in the zones of normal radiation level, which leaves the red soil radioactivity there less a threat to the environment as well as the human health.
Currently, the uncontrolled exposure of individuals to X-rays during medical examinations represents a substantial danger that threatens both medical professionals and patients. Therefore, radiation dosimetry for low X-ray doses is a very important control of radiation practice in medical diagnostic radiology. In line with this, the current study proposes a valuable dosimeter-based PVA thin film doubly doped with silver nitrate salt and nitro blue tetrazolium dye. The nanocomposite film was prepared via a simple casting method and the different processing parameters were optimized. The performance of radiation detection was evaluated according to optical, chromic, chemical and structural changes after exposure to variable low X-ray doses (0, 2, 4, 10 and 20 mGy). The different film labels exhibited an excellent stability behavior in dark and light upon 30 days of storage. The UV-Vis spectrophotometric study showed a gradual increase in the maximum absorbance as a function of the dose and the corresponding response curve confirmed this linear variation (R = 0.998). A clear structural modification was recorded via X-ray diffraction (XRD) analysis revealing the increase in crystallinity with the level of the dose received by the nanocomposite films. Microscopic surface analysis via SEM assessments revealed a significant morphological change in PVA/Ag+/NBT films exposed to increased radiation doses and typical dendrites growing in needle- or tree-like microstructures appeared with a high X-ray dose. Finally, the nanocomposite films before and after irradiation were evaluated via a spectrocolorimetric study and the different CIELab coordinates, the color difference, as well as the color strength, showed a linear correlation with the intensity of the applied dose. This new dosimeter design could, therefore, provide a promising and efficient alternative for prompt and accurate detection of low X-rays doses in diagnostic radiology.
Lightweight and lead-free radiation shields are increasingly developed to overcome the toxicity and handling challenges associated with conventional heavy-metal-based materials. In this study, the -ray attenuation behavior of polymer–zeolite composites was examined by reinforcing high-density polyethylene (HDPE) and polylactic acid (PLA) with natural clinoptilolite zeolite at concentrations of 10–40 wt%. Photon-interaction parameters, including the linear attenuation coefficient (), half-value layer (HVL), mean free path (), and effective atomic number (), were evaluated over 15 keV–15 MeV using the Phy-X/PSD platform. Zeolite incorporation consistently enhanced photon attenuation, particularly at low energies dominated by the photoelectric effect. At 15 keV, the HVL decreased from 0.60 cm to 0.08 cm for HDPE and from 0.043 cm to 0.033 cm for PLA as the zeolite loading increased to 40 wt%. Correspondingly, increased from 2.7 to 4.3 for HDPE and from 6.5 to 11.6 for PLA, while reached approximately 41 cm−1 and 56 cm−1 at 15 keV for the respective 40 wt% composites. Beyond about 1 MeV, differences between compositions became minimal as Compton scattering dominated. PLA–zeolite composites exhibited higher and lower HVL than HDPE–zeolite, whereas HDPE maintained an advantage in mixed-field environments owing to its hydrogen-rich matrix. The results confirm that zeolite-reinforced polymers are safe, low-cost, and lightweight materials suitable for radiation shielding in medical, nuclear, and aerospace applications.
Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively. Various concentrations of NBT dye (ranging from 0.75 to 15 g/L) were tested to determine the optimal concentration for maximum efficiency. The films were exposed to low doses of X-rays ranging from 20 to 100 mGy. The PVA/NBT films exhibited good stability for 30 days after irradiation when stored in darkness. UV–visible absorption spectra showed a peak at 376 nm, shifting to 384 nm after exposure to X-rays. Furthermore, the response curve based on UV–Vis absorptions revealed a linear increase in absorbance with increased radiation doses up to 60 mGy (R = 0.99). XRD analysis indicated significant structural rearrangements in films with higher NBT concentrations and radiation doses. Specifically, X-ray irradiation caused two distinct peaks to shift from 2θ = 20.12° and 40.18° to 2θ = 19.66° and 41.24°. SEM analysis revealed that exposure to increased radiation doses resulted in significant morphological changes in PVA/NBT films, resembling torn tree trunks, especially with higher NBT concentrations. The preparation method was validated by XRF analysis, and the solubility of the NBT salt was excellent, with an R2 value of 0.9656. Results from Spectro colorimetric studies indicated that different CIEL∗a∗b∗ coordinates, as well as the total color difference (ΔE∗ab) and color strength (K/S), were directly proportional to the applied dose intensity, correlating with increasing NBT concentration. The PVA/NBT dosimeter containing 10 g/L of NBT shows promising potential as an effective alternative for the prompt and accurate detection of low X-ray doses in diagnostic radiology.
Ensuring the limited exposure of both patients and medical professionals to radiation during examinations is paramount. One effective approach is the utilization of a film dosimeter that is not only efficient but also easy to carry. In this research, we employed polyvinyl alcohol/nitro blue tetrazolium (PVA/NBT) with varying concentrations of NBT dye (ranging from 0.015 to 0.3 g) to identify the most optimal concentration. These films were subjected to low doses of gamma rays (8, 25, 55 and 96 mGy) emitted from 3 Cs-137 sources. XRF analysis confirmed the effectiveness of the preparation method used, and the NBT salt exhibited excellent solubility (R2 = 0.93). The films exhibited an increasing yellow hue as the concentration of NBT dye rose. Following irradiation, they took on a yellowish-brown tint, intensifying with higher gamma doses. PVA/NBT films, when stored in the dark, demonstrated good stability for 30 days post-irradiation. Analysis using ImageJ software unveiled that the relative density of the red color heightened proportionally with the concentration of NBT dye. XRD patterns showcased the clarity of structural rearrangements occurring after irradiation with high NBT concentrations. Two distinct peaks were registered at 2θ = 20.12 and 40.94 °, which shifted to 2θ = 19.74 and 41.30 ° post-gamma irradiation. The CIELab system study and K/S color strength indicated that increasing the NBT dye concentration led to a linear rise in color strength with escalating low gamma doses. Through a comprehensive assessment, it is concluded that PVA/NBT film can be effectively employed as a dosimeter for low gamma doses in diagnostic radiology. HIGHLIGHTS Nine different concentrations of NBT dye were used to prepare PVA/NBT films. The standard dose scale in diagnostic radiology (mGy) was applied in this work. CIELab system parameters showed a linear increase with increasing applied dose. XRD pattern recorded a shifted peak after irradiation from 2θ = 20.12 to 19.74 °. The dose-response was affected by increasing the NBT dye to a certain concentration. GRAPHICAL ABSTRACT