Ahmed Alharbi

Dr. Ahmed Alharbi

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2026 in Polymers
Verified
Journal Article
Open access
PDF file
AAAhmed Alharbi
Ahmed Alharbi
NANassar Nasser Asemi
Nassar Nasser Asemi
HAHamed Alnagran
Hamed Alnagran
This study evaluates lead-free high-density polyethylene (HDPE) composites reinforced with high-Z oxides (Bi2O3, WO3, Gd2O3, TeO2, and a Bi2O3/WO3 hybrid) as lightweight materials for gamma-ray and fast-neutron shielding. A hybrid computational framework combining Phy-X/PSD with Geant4 Monte Carlo simulations was used to obtain key shielding parameters, including the linear and mass attenuation coefficients (μ, μ/ρ), half-value layer (HVL), mean free path (MFP), effective atomic number (Zeff), effective electron density (Neff), exposure and energy-absorption buildup factors (EBF, EABF), and fast-neutron removal cross section (ΣR). The incorporation of heavy oxides produced a pronounced improvement in gamma-ray attenuation, particularly at low energies, where the linear attenuation coefficient increased from below 1 cm−1 for neat HDPE to values exceeding 130–150 cm−1 for Bi- and W-rich composites. In the intermediate Compton-scattering region (≈0.3–1 MeV), all oxide-reinforced systems maintained a clear attenuation advantage, with μ values around 0.12–0.13 cm−1 compared with ≈0.07 cm−1 for pure HDPE. At higher photon energies, the dense composites continued to outperform the polymer matrix, yielding μ values of approximately 0.07–0.09 cm−1 versus ≈0.02 cm−1 for HDPE due to enhanced pair-production interactions. The Bi2O3/WO3 hybrid composite exhibited attenuation behavior comparable, and in some regions slightly exceeding, that of the single-oxide systems, indicating that mixed fillers can effectively balance density and shielding efficiency. Oxide addition significantly reduced exposure and energy-absorption buildup factors below 1 MeV, with a moderate increase at higher energies associated with secondary radiation processes. Fast-neutron removal cross sections were also modestly enhanced, with Gd2O3-containing composites showing the highest values due to the combined effects of hydrogen moderation and neutron capture. The close agreement between Phy-X/PSD and Geant4 results confirms the reliability of the dual-method approach. Overall, HDPE composites containing about 60 wt.% oxide filler offer a practical compromise between shielding performance, manufacturability, and environmental safety, making them promising candidates for medical, nuclear, and aerospace radiation-protection applications.

26 November 2025 in Polymers
Verified
Journal Article
Open access
PDF file
AAAhmed Alharbi
Ahmed Alharbi
HAHamed Alnagran
Hamed Alnagran
SASaleh Alashrah
Saleh Alashrah
Lightweight and lead-free radiation shields are increasingly developed to overcome the toxicity and handling challenges associated with conventional heavy-metal-based materials. In this study, the γ-ray attenuation behavior of polymer–zeolite composites was examined by reinforcing high-density polyethylene (HDPE) and polylactic acid (PLA) with natural clinoptilolite zeolite at concentrations of 10–40 wt%. Photon-interaction parameters, including the linear attenuation coefficient (μ), half-value layer (HVL), mean free path (λ), and effective atomic number (Zeff), were evaluated over 15 keV–15 MeV using the Phy-X/PSD platform. Zeolite incorporation consistently enhanced photon attenuation, particularly at low energies dominated by the photoelectric effect. At 15 keV, the HVL decreased from 0.60 cm to 0.08 cm for HDPE and from 0.043 cm to 0.033 cm for PLA as the zeolite loading increased to 40 wt%. Correspondingly, Zeff increased from 2.7 to 4.3 for HDPE and from 6.5 to 11.6 for PLA, while μ reached approximately 41 cm−1 and 56 cm−1 at 15 keV for the respective 40 wt% composites. Beyond about 1 MeV, differences between compositions became minimal as Compton scattering dominated. PLA–zeolite composites exhibited higher μ and lower HVL than HDPE–zeolite, whereas HDPE maintained an advantage in mixed-field environments owing to its hydrogen-rich matrix. The results confirm that zeolite-reinforced polymers are safe, low-cost, and lightweight materials suitable for radiation shielding in medical, nuclear, and aerospace applications.

11 January 2026 in Polymers
Verified
Journal Article
Open access
PDF file
AAAhmed Alharbi
Ahmed Alharbi
Lightweight, lead-free polymer–mineral composites have attracted increasing interest as radiation-attenuating materials for applications where reduced mass and environmental compatibility are required. In this work, the γ-ray attenuation behavior of poly(ether ether ketone) (PEEK) reinforced with natural palygorskite and pumice was evaluated at filler concentrations of 10–40 wt%. Photon interaction parameters, including the linear attenuation coefficient (μ), half-value layer (HVL), mean free path (λ), and effective atomic number (Zeff), were computed over the energy range 15 keV–15 MeV using the Phy-X/PSD platform and validated through full Geant4 Monte Carlo transmission simulations. At 15 keV, μ increased from 1.46cm−1 for pure PEEK to 4.21cm−1 and 8.499cm−1 for the 40 wt% palygorskite- and pumice-filled composites, respectively, reducing the HVL from 0.69 cm to 0.24 cm and 0.11 cm. The corresponding Zeff values increased from 6.5 (pure PEEK) to 9.4 (40 wt% palygorskite) and 15.3 (40 wt% pumice), reflecting the influence of higher-Z oxide constituents in pumice. At higher photon energies, the attenuation curves converged as Compton scattering became dominant, although pumice-filled PEEK retained marginally higher μ and shorter λ up to the MeV region. These findings demonstrate that natural mineral fillers can enhance the photon attenuation behavior of PEEK while retaining the known thermal stability and mechanical performance of the polymer matrix as reported in the literature, indicating their potential use as lightweight, secondary radiation-attenuating components in medical, industrial, and aerospace applications.

1 June 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
AAAhmed Alharbi
Ahmed Alharbi
The position sensitivity and the signal performance of a novel planar segmented detector has been studied theoretically. This detector was manufactured for gamma emission tomography (GET) and Compton imaging applications which incorporates a segmented cathode geometry to facilitate precise three-dimensional localization of γ-ray interactions. The position resolution of the detector was evaluated as a function of γ-ray interaction positions using simulated detector signals in an experimental setting. The effects of RMS noise and timing misalignments were studied in detail. Under ideal noise-free conditions, the detector achieved sub-millimeter resolution across most regions of the active volume. When RMS noise and timing shifts were introduced, the resolution degraded, ranging up to 6 mm, with significant variations near segment boundaries and under higher noise levels. These simulations highlight the potential of the planar segmented HPGe detector to provide excellent position sensitivity and energy resolution in γ-ray spectroscopy. The detector is suitable for standalone applications and integration into larger systems, offering enhanced performance compared to conventional γ-ray imaging devices.

22 June 2026 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
SASaleh Alashrah
Saleh Alashrah
AAAhmed Alharbi
Ahmed Alharbi

27 September 2025 in Physics Letters B
Verified
Journal Article
Open access
APA.M. Plaza
A.M. Plaza
JPJ. Pakarinen
J. Pakarinen
RJR. Julin
R. Julin
PPP. Papadakis
P. Papadakis
RHR.-D. Herzberg
R.-D. Herzberg
GZG.L. Zimba
G.L. Zimba