Silvana Girolimetti

Dr. Silvana Girolimetti

Istituto Superiore di Sanità

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 November 2022 in Analytica
Verified
Journal Article
Open access
PDF file
Angela SantilioAngela Santilio
Angela Santilio
SGSilvana Girolimetti
Silvana Girolimetti
VPvalentina picardo
valentina picardo
Picloram and 2,4-D are systemic herbicides used to control a wide range of broad-leaved weeds and post-emergence annual and perennial broad-leaved weeds, respectively. The use of plant protection products containing Picloram and 2,4-D necessitates the development of analytical methods, useful for the laboratories focused on control, for monitoring. In this study, we designed and validated an analytical method for the rapid determination of picloram and 2,4-D by HPLC-DAD. The method involves the extraction of the substances by sonication of the sample with methanol, followed by dilution in acetonitrile, and direct injection on a liquid chromatography system, based on the use of a Gemini C18 column. We used an isocratic mobile elution consisting of acetonitrile and water acidified 1% with H3PO4 (50:50, v/v). We validated the proposed method, which demonstrated linearity within the concentration range of 0.01–0.028 mg/mL for picloram and 2,4-D, with a correlation coefficient (R2) of 0.9993 for picloram and 0.9999 for 2,4-D. We considered precision, repeatability and selectivity in the validation. The repeatability of the method expressed as percent of relative standard deviation (%RSD) was lower than 1% for both substances. The proposed method is suitable for the simultaneous determination of picloram and 2,4-D in pesticide formulations.

20 June 2026 in Foods
Verified
Journal Article
Open access
PDF file
Angela SantilioAngela Santilio
Angela Santilio
SGSilvana Girolimetti
Silvana Girolimetti
The European legislation sets the maximum residue levels for glyphosate in sesame seeds at 0.1 mg/kg (EU Regulation n. 293/2013) and for glufosinate and N-Acetyl-glufosinate expressed as glufosinate at 0.03 mg/kg (EU Regulation n. 2016/1002). The present work describes a rapid methodology to determine glyphosate, glufosinate and its metabolite and N-Acetyl-glufosinate in sesame seeds by LC/MS/MS. The method was studied in the framework of EU proficiency tests on sesame seeds. The analytical method was developed using methanol acidified with formic acid (1%, v/v) extraction with an isotope internal standard, followed by LC/MS/MS detection. The recoveries were performed in the range of 0.05–0.5 mg/kg for glyphosate and 0.02–0.2 mg/kg for glufosinate and N-Acetyl-glufosinate. All the recovery values were between 70 and 114%, which is the acceptable interval according to SANTE/11312/2021; the relative standard deviation (%RSD) values met the requirement of 0.999. We considered precision, matrix effect, LOD and LOQ in the validation. All the parameters were in agreement with the acceptability criteria of the document SANTE/11312/2021. The method was considered suitable for the determination of the studied substances on sesame seeds.