Sulaiman Ab Ghani

Prof. Sulaiman Ab Ghani


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2009 in Fuel Cells
Verified
Journal Article
Closed access
PDF file
RTR. M. A. Tehrani
R. M. A. Tehrani
SGSulaiman Ab Ghani
Sulaiman Ab Ghani

30 November 2012 in Journal of Sol-Gel Science and Technology
Verified
Journal Article
Closed access
PDF file
Anish KhanAnish Khan
Anish Khan
Abdullah M. AsiriAbdullah M. Asiri
Abdullah M. Asiri
AKAftab Aslam Parwaz Khan
Aftab Aslam Parwaz Khan
MRMalik Abdul Rub
Malik Abdul Rub
Naved AzumNaved Azum
Naved Azum
SGSulaiman Ab Ghani
Sulaiman Ab Ghani


19 October 2012 in Journal of Solid State Electrochemistry
Verified
Journal Article
Closed access
PDF file
JLJoanna Lim Wee Ling
Joanna Lim Wee Ling
SGSulaiman Ab Ghani
Sulaiman Ab Ghani

18 January 2011 in Sensors
Verified
Journal Article
Open access
PDF file
AHAhmed Khudhair Hassan
Ahmed Khudhair Hassan
BSBahruddin Saad
Bahruddin Saad
SGSulaiman Ab Ghani
Sulaiman Ab Ghani
RARohana Adnan
Rohana Adnan
ARAfidah Abdul Rahim
Afidah Abdul Rahim
SASouad Al-Araji
Souad Al-Araji
Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on β-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.

6 November 2012 in Sensors
Verified
Journal Article
Open access
PDF file
TTTara F. Tahir
Tara F. Tahir
ASAbdussalam Salhin
Abdussalam Salhin
SGSulaiman Ab Ghani
Sulaiman Ab Ghani
A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1.