Current methods for ergonomic assessment often use video-analysis to estimate wrist postures during occupational tasks. Wearable sensing and machine learning have the potential to automate this tedious task, and in doing so greatly extend the amount of data available to clinicians and researchers. A method of predicting wrist posture from inertial measurement units placed on the wrist and hand via a deep convolutional neural network has been developed. This study has quantified the accuracy and reliability of the postures predicted by this system relative to the gold standard of optoelectronic motion capture. Ten participants performed 3 different simulated occupational tasks on 2 occasions while wearing inertial measurement units on the hand and wrist. Data from the occupational task recordings were used to train a convolutional neural network classifier to estimate wrist posture in flexion/extension, and radial/ulnar deviation. The model was trained and tested in a leave-one-out cross validation format. Agreement between the proposed system and optoelectronic motion capture was 65% with = 0.41 in flexion/extension and 60% with = 0.48 in radial/ulnar deviation. The proposed system can predict wrist posture in flexion/extension and radial/ulnar deviation with accuracy and reliability congruent with published values for human estimators. This system can estimate wrist posture during occupational tasks in a small fraction of the time it takes a human to perform the same task. This offers opportunity to expand the capabilities of practitioners by eliminating the tedium of manual postural assessment.
Gait analysis provides an important tool for the study and clinical evaluation of conditions which affect knee joint biomechanics. Collection of knee joint kinematics in real world environments during locomotor activities of daily living could provide quantitative evidence to help understand functional impairment. Unfortunately, the high cost and necessary technical expertise associated with current commercially available systems for kinematic monitoring serve as an impediment to their adoption outside of specialized research groups. We have developed a low-cost, custom wearable device to address these shortcomings. The 3D printed device is capable of measuring knee flexion/extension (F/E) and adduction/abduction (AD/AB) angles. Here, we present a gold standard validation of the novel device against an optoelectronic motion capture system (MCS). Data were collected during a treadmill walking task from 8 participants on 2 separate occasions. Agreement with the MCS was quantified via root mean squared error (RMSE), coefficients of multiple correlation (CMC), paired dependent t-tests and Bland-Altman analyses. The wearable device had an overall RMSE of 3.0° and 2.7° and a CMC of 0.97 and 0.91 in F/E and AD/AB respectively. Wearable device error showed no significant differences between test occasions, and Bland-Altman analyses showed low bias with narrow limits of agreement. These results demonstrate the capability of the device to accurately and reliably monitor knee F/E and AD/AB angles showing strong potential for field implementation.
Wrist motion provides an important metric for disease monitoring and occupational risk assessment. The collection of wrist kinematics in occupational or other real-world environments could augment traditional observational or video-analysis based assessment. We have developed a low-cost 3D printed wearable device, capable of being produced on consumer grade desktop 3D printers. Here we present a preliminary validation of the device against a gold standard optical motion capture system. Data were collected from 10 participants performing a static angle matching task while seated at a desk. The wearable device output was significantly correlated with the optical motion capture system yielding a coefficient of determination (R) of 0.991 and 0.972 for flexion/extension (FE) and radial/ulnar deviation (RUD) respectively (p < 0.0001). Error was similarly low with a root mean squared error of 4.9° (FE) and 3.9° (RUD). Agreement between the two systems was quantified using Bland–Altman analysis, with bias and 95% limits of agreement of 3.1° ± 7.4° and −0.16° ± 7.7° for FE and RUD, respectively. These results compare favourably with current methods for occupational assessment, suggesting strong potential for field implementation.