Jeeyong Kim

Prof. Dr. Jeeyong Kim

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JKJeeyong Kim
Jeeyong Kim
BPBorae G. Park
Borae G. Park
DLDa Hye Lim
Da Hye Lim
Woong sik JangWoong sik Jang
Woong sik Jang
JNJeonghun Nam
Jeonghun Nam
CLChae Seung Lim
Chae Seung Lim
Introduction: The rapid and accurate diagnosis of tuberculosis (TB) is important to reduce morbidity and mortality rates and risk of transmission. Therefore, molecular detection methods such as a real-time PCR–based assay for Mycobacterium tuberculosis (MTB) have been commonly used for diagnosis of TB. Loop-mediated isothermal amplification (LAMP) assay was believed to be a simple, quick, and cost-effective isothermal nucleic acid amplification diagnostic test for infectious diseases. In this study, we designed an in-house multiplex LAMP assay for the differential detection of MTB and non-tuberculosis mycobacterium (NTM), and evaluated the assay using clinical samples. Material and methods: For the multiplex LAMP assay, two sets of specific primers were designed: the first one was specific for IS6110 genes of MTB, and the second one was universal for rpoB genes of mycobacterium species including NTM. MTB was confirmed with a positive reaction with both primer sets, and NTM was identified with a positive reaction by only the second primer set without a MTB-specific reaction. Total 333 clinical samples were analyzed to evaluate the multiplex LAMP assay. Clinical samples were composed of 195 positive samples (72 MTB and 123NTM) and 138 negative samples. All samples were confirmed positivity or negativity by real-time PCR for MTB and NTM. Analytical sensitivity and specificity were evaluated for the multiplex LAMP assay in comparison with acid fast bacilli staining and the culture method. Results: Of 123 NTM samples, 121 were identified as NTM and 72/72 MTB were identified as MTB by the multiplex LAMP assay. False negative reactions were seen only in two NTM positive samples with co-infection of Candida spp. All 138 negative samples were identified as negative for MTB and NTM. Analytical sensitivity of the multiplex LAMP assay was 100% (72/72) for MTB, and 98.4% (121/123) for NTM. And the specificity of assay was 100% (138/138) for all. Conclusions: Our newly designed multiplex LAMP assay for MTB and NTM showed relatively good sensitivity in comparison with previously published data to detect isolated MTB. This multiplex LAMP assay is expected to become a useful tool for detecting and differentiating MTB from NTM rapidly at an acceptable sensitivity.

29 July 2019 in Antimicrobial Resistance & Infection Control
Verified
Journal Article
Open access
PDF file
YKYoung Jin Ko
Young Jin Ko
JKJeeyong Kim
Jeeyong Kim
HKHa-Nui Kim
Ha-Nui Kim
SYSoo-Young Yoon
Soo-Young Yoon
CLChae Seung Lim
Chae Seung Lim
CLChang Kyu Lee
Chang Kyu Lee
There are growing concerns regarding the spread of carbapenemase-producing organisms (CPOs) among patients in long-term care facilities (LTCFs) and hospitals in South Korea. We have established a screening protocol for the detection of CPOs in high-risk patients upon admission to intensive care units (ICUs). The diagnostic performance of the Xpert Carba-R assay was compared to that of rectal culture for CPO detection in high-risk patients upon ICU admission. A total of 408 consecutive rectal swabs were obtained from December 2016 to December 2017. CPO screening was performed using the Xpert Carba-R assay (Cepheid, Sunnyvale, CA, USA). When a carbapenemase gene was detected, additional rectal swabs were incubated overnight and inoculated on chromID CARBA medium (bioMérieux, Marcy l’Etoile, France). Bacterial carbapenemase genes, including blaKPC, blaNDM, blaVIM, blaIMP-1, and blaOXA-48, were confirmed by conventional PCR. The diagnostic performance of the Carba-R assay was ascertained based on the culture results. The prevalence of CPO carriage was 7.4% according to the Carba-R assay and 3.7% according to rectal culture. The median Ct values of IMP-1 and KPC were significantly different (35.2 vs. 26.6, P = 0.0143). The overall sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of the Carba-R assay were 100.0% (95% confidence interval [CI], 78.2–100.0), 96.7% (94.4–98.2), 53.6% (40.4–66.4) and 100.0% (99.0–100.0), respectively. We demonstrated the prevalence of CPO carriage in high-risk patients upon ICU admission and evaluated the diagnostic performance of the Carba-R assay. The combined use of the Xpert Carba-R assay and culture produces rapid and reliable results for the active surveillance of rectal CPO in ICU patients.

1 January 2008
Verified
Journal Article
Closed access
KRKyoung Ho Roh
Kyoung Ho Roh
JKJeeyong Kim
Jeeyong Kim
MNMyung-Hyun Nam
Myung-Hyun Nam
SYSooyung Yoon
Sooyung Yoon
CLChang Kyu Lee
Chang Kyu Lee
YCYunjung Cho
Yunjung Cho

11 September 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Woong sik JangWoong sik Jang
Woong sik Jang
DLDa Hye Lim
Da Hye Lim
JNJeonghun Nam
Jeonghun Nam
DMDo-CiC Mihn
Do-CiC Mihn
HSHaan Woo Sung
Haan Woo Sung
JKJeeyong Kim
Jeeyong Kim
Influenza, which is an acute respiratory disease caused by the influenza virus, represents a worldwide public health and economic problem owing to the significant morbidity and mortality caused by its seasonal epidemics and pandemics. Sensitive and convenient methodologies for the detection of influenza viruses are important for clinical care and infection control as well as epidemiological investigations. Here, we developed a multiplex reverse transcription loop-mediated isothermal amplification (RT-LAMP) with quencher/fluorescence oligonucleotides connected by a 5′ backward loop (LF or LB) primer for the detection of two subtypes of influenza viruses: Influenza A (A/H1 and A/H3) and influenza B. The detection limits of the multiplex RT-LAMP assay were 103 copies and 102 copies of RNA for influenza A and influenza B, respectively. The sensitivities of the multiplex influenza A/B/IC RT-LAMP assay were 94.62% and 97.50% for influenza A and influenza B clinical samples, respectively. The specificities of the multiplex influenza A/B/IC RT-LAMP assay were 100% for influenza A, influenza B, and healthy clinical samples. In addition, the multiplex influenza A/B/IC RT-LAMP assay had no cross-reactivity with other respiratory viruses.

1 June 2019 in Journal of Chromatography A
Verified
Journal Article
Closed access
JNJeonghun Nam
Jeonghun Nam
JYJung Yoon
Jung Yoon
JKJeeyong Kim
Jeeyong Kim
Woong sik JangWoong sik Jang
Woong sik Jang
Chae Seung LimChae Seung Lim
Chae Seung Lim

1 January 2007 in Yonsei Medical Journal
Verified
Journal Article
Open access
PDF file
HJHye Won Jeong
Hye Won Jeong
JSJang-Wook Sohn
Jang-Wook Sohn
MKMin Ja Kim
Min Ja Kim
JCJung Woo Choi
Jung Woo Choi
CKChul Hwan Kim
Chul Hwan Kim
YCYunjung Cho
Yunjung Cho
Jeong HW, et al. Yonsei Med J. 2007 Jun;48(3):531-534. https://doi.org/10.3349/ymj.2007.48.3.531