Woong sik Jang

Dr. Woong sik Jang

Laboratory Medicine, Korea University Guro Hospital, Seoul, Republic of Korea
+1
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Woong sik JangWoong sik Jang
Woong sik Jang
DLDa Hye Lim
Da Hye Lim
JYJung Yoon
Jung Yoon
AKAhran Kim
Ahran Kim
MLMinsup Lim
Minsup Lim
Chae Seung LimChae Seung Lim
Chae Seung Lim
A newly identified coronavirus, designated as severe acute respiratory syndrome coronavirus 2 (SARS CoV-2), has spread rapidly from its epicenter in China to more than 150 countries across six continents. In this study, we have designed three reverse-transcription loop-mediated isothermal amplification (RT-LAMP) primer sets to detect the RNA-dependent RNA polymerase (RdRP), Envelope (E) and Nucleocapsid protein (N) genes of SARS CoV-2. For one tube reaction, the detection limits for five combination SARS CoV-2 LAMP primer sets (RdRP/E, RdRP/N, E/N, RdRP/E/N and RdRP/N/Internal control (actin beta)) were evaluated with a clinical nasopharyngeal swab sample. Among the five combination, the RdRP/E and RdRP/N/IC multiplex LAMP assays showed low detection limits. The sensitivity and specificity of the RT-LAMP assay were evaluated and compared to that of the widely used Allplex™ 2019-nCoV Assay (Seegene, Inc., Seoul, South Korea) and PowerChek™ 2019-nCoV Real-time PCR kit (Kogenebiotech, Seoul, South Korea) for 130 clinical samples from 91 SARS CoV-2 patients and 162 NP specimens from individuals with (72) and without (90) viral respiratory infections. The multiplex RdRP (FAM)/N (CY5)/IC (Hex) RT-LAMP assay showed comparable sensitivities (RdRP: 93.85%, N: 94.62% and RdRP/N: 96.92%) to that of the Allplex™ 2019-nCoV Assay (100%) and superior to those of PowerChek™ 2019-nCoV Real-time PCR kit (RdRP: 92.31%, E: 93.85% and RdRP/E: 95.38%).

1 April 2018 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
JNJeonghun Nam
Jeonghun Nam
Woong sik JangWoong sik Jang
Woong sik Jang
CLChae Seung Lim
Chae Seung Lim

16 March 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
JYJung Yoon
Jung Yoon
Woong sik JangWoong sik Jang
Woong sik Jang
JNJeonghun Nam
Jeonghun Nam
DMDohsik Minn (Do-CiC Mihn)
Dohsik Minn (Do-CiC Mihn)
Chae Seung LimChae Seung Lim
Chae Seung Lim
Rapid diagnosis and parasitemia measurement is crucial for management of malaria. Microscopic examination of peripheral blood (PB) smears is the gold standard for malaria detection. However, this method is labor-intensive. Here, we aimed to develop a completely automated microscopic system for malaria detection and parasitemia measurement. The automated system comprises a microscope, plastic chip, fluorescent dye, and an image analysis program. Analytical performance was evaluated regarding linearity, precision, and limit of detection and was compared with that of conventional microscopic PB smear examination and flow cytometry. The automated microscopic malaria parasite detection system showed a high degree of linearity for Plasmodium falciparum culture (R2 = 0.958, p = 0.005) and Plasmodium vivax infected samples (R2 = 0.931, p = 0.008). Precision was defined as the %CV of the assay results at each level of parasitemia and the %CV value for our system was lower than that for microscopic examination for all densities of parasitemia. The limit of detection analysis showed 95% probability for parasite detection was 0.00066112%, and a high correlation was observed among all three methods. The sensitivity and specificity of the system was both 100% (n = 21/21) and 100% (n = 50/50), respectively, and the system correctly identified all P. vivax and P. falciparum samples. The automated microscopic malaria parasite detection system offers several advantages over conventional microscopy for rapid diagnosis and parasite density monitoring of malaria.

13 March 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Woong sik JangWoong sik Jang
Woong sik Jang
SKSeung Yeon Kwak
Seung Yeon Kwak
WMWin Lai May
Win Lai May
DYDong June Yang
Dong June Yang
JNJeonghun Nam
Jeonghun Nam
Chae Seung LimChae Seung Lim
Chae Seung Lim
Dengue is an increasing public health concern worldwide and requires efficient laboratory diagnostics. We evaluated three commercially available dengue rapid diagnostic tests—the Humasis Dengue Combo NS1 & IgG/IgM (Humasis, Korea), SD Bioline Dengue Duo NS1 Ag & IgG/IgM (SD Bioline, Korea), and CareUS Dengue Combo NS1 and IgM/IgG kits (WellsBio, Korea)—and compared them to reference immunoglobulin M (IgM) or immunoglobulin G (IgG) ELISAs and quantitative reverse transcription polymerase chain reaction (qRT-PCR) assays. In total, 109 dengue-positive samples from children with acute symptomatic dengue and 63 dengue-negative samples from febrile and asymptomatic individuals were collected. For the nonstructural 1 protein (NS1) Ag test, the sensitivity and specificity were in the following order: CareUS (79.82 and 100%), Humasis (63.30 and 100%), and SD Bioline (48.62 and 100%). For IgM and IgG, CareUS had the highest sensitivities and specificities (89.91 and 100%; 82.57 and 100%, respectively), followed by SD Bioline (60.55 and 100%, 77.98 and 100%, respectively), and Humasis (51.38 and 98.21%, 72.48 and 95.24%, respectively). The IgM kits were more sensitive than the NS1 Ag or IgG kits; however, combining NS1 Ag and IgM reduced the number of missed cases. Therefore, the NS1 Ag plus IgM dengue kits increase the accuracy of the results. In our study, the CareUS Dengue Combo NS1 and IgM/IgG kit showed higher accuracy in performance with reference to qRT-PCR and ELISA results.

6 January 2021 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JKJeeyong Kim
Jeeyong Kim
BPBorae G. Park
Borae G. Park
DLDa Hye Lim
Da Hye Lim
Woong sik JangWoong sik Jang
Woong sik Jang
JNJeonghun Nam
Jeonghun Nam
CLChae Seung Lim
Chae Seung Lim
Introduction: The rapid and accurate diagnosis of tuberculosis (TB) is important to reduce morbidity and mortality rates and risk of transmission. Therefore, molecular detection methods such as a real-time PCR–based assay for Mycobacterium tuberculosis (MTB) have been commonly used for diagnosis of TB. Loop-mediated isothermal amplification (LAMP) assay was believed to be a simple, quick, and cost-effective isothermal nucleic acid amplification diagnostic test for infectious diseases. In this study, we designed an in-house multiplex LAMP assay for the differential detection of MTB and non-tuberculosis mycobacterium (NTM), and evaluated the assay using clinical samples. Material and methods: For the multiplex LAMP assay, two sets of specific primers were designed: the first one was specific for IS6110 genes of MTB, and the second one was universal for rpoB genes of mycobacterium species including NTM. MTB was confirmed with a positive reaction with both primer sets, and NTM was identified with a positive reaction by only the second primer set without a MTB-specific reaction. Total 333 clinical samples were analyzed to evaluate the multiplex LAMP assay. Clinical samples were composed of 195 positive samples (72 MTB and 123NTM) and 138 negative samples. All samples were confirmed positivity or negativity by real-time PCR for MTB and NTM. Analytical sensitivity and specificity were evaluated for the multiplex LAMP assay in comparison with acid fast bacilli staining and the culture method. Results: Of 123 NTM samples, 121 were identified as NTM and 72/72 MTB were identified as MTB by the multiplex LAMP assay. False negative reactions were seen only in two NTM positive samples with co-infection of Candida spp. All 138 negative samples were identified as negative for MTB and NTM. Analytical sensitivity of the multiplex LAMP assay was 100% (72/72) for MTB, and 98.4% (121/123) for NTM. And the specificity of assay was 100% (138/138) for all. Conclusions: Our newly designed multiplex LAMP assay for MTB and NTM showed relatively good sensitivity in comparison with previously published data to detect isolated MTB. This multiplex LAMP assay is expected to become a useful tool for detecting and differentiating MTB from NTM rapidly at an acceptable sensitivity.

1 October 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JNJeonghun Nam
Jeonghun Nam
Woong sik JangWoong sik Jang
Woong sik Jang
JKJisu Kim
Jisu Kim
HLHyukjin Lee
Hyukjin Lee
Chae Seung LimChae Seung Lim
Chae Seung Lim