Christos Gkizas

Christos Gkizas


Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 December 2017 in International Journal of Hyperthermia
Verified
Journal Article
Open access
Dimitrios FilippiadisDimitrios Filippiadis
Dimitrios Filippiadis
CGChristos Gkizas
Christos Gkizas
MCM. Chrysofos
M. Chrysofos
ASA. Siatelis
A. Siatelis
GVGeorgios Velonakis
Georgios Velonakis
NKN. Kelekis
N. Kelekis
Objectives: Percutaneous ablation is an expanding, minimally invasive approach for small- to medium-sized renal masses. The purpose of this study is to review safety, and mid-term efficacy of percutaneous microwave ablation (MWA) for Renal Cell Carcinoma (RCC) treatment using a high power microwave system. Methods and materials: Institutional database research identified 50 consecutive patients with a single lesion resembling renal cell carcinoma in CT and MRI who underwent percutaneous microwave ablation using a high power microwave system. All patients underwent biopsy on the same session with ablation using an 18G semi-automatic soft tissue biopsy needle. Contrast-enhanced computed tomography or magnetic resonance imaging was used for post-ablation follow-up. Patient and tumour characteristics, microwave technique, complications and pattern of recurrence were evaluated. Results: Mean patient age was 74 years (male–female: 31–19). Average lesion size was 3.1 cm (range 2.0–4.3 cm). Biopsy results report RCC (n = 48), inflammatory myofibroblastic tumour (n = 1), and non-diagnostic sample (n = 1). The 3-year overall survival was 95.8% (46/48). Two patients died during the 3-year follow-up period due to causes unrelated to the MW ablation and to the RCC. Minor complications including haematomas requiring nothing but observation occurred at 4% (2/50) of the cases. Local recurrence of 6.25% (3/48) was observed with 2/3 cases being re-treated achieving a total clinical success of 97.9% (47/48 lesions). Conclusions: Percutaneous microwave ablation of RCC using a high power microwave system is a safe and efficacious technique for the treatment of small- to medium-sized renal masses.

Verified
Journal Article
Open access
PDF file
BLBenjamin Longère
Benjamin Longère
PAPaul-Edouard Allard
Paul-Edouard Allard
CGChristos Gkizas
Christos Gkizas
ACAugustin Coisne
Augustin Coisne
JHJustin Hennicaux
Justin Hennicaux
FPFRANCOIS PONTANA
FRANCOIS PONTANA
Background and objective: Cardiac magnetic resonance (CMR) is a key tool for cardiac work-up. However, arrhythmia can be responsible for arrhythmia-related artifacts (ARA) and increased scan time using segmented sequences. The aim of this study is to evaluate the effect of cardiac arrhythmia on image quality in a comparison of a compressed sensing real-time (CSrt) cine sequence with the reference prospectively gated segmented balanced steady-state free precession (Cineref) technique regarding ARA. Methods: A total of 71 consecutive adult patients (41 males; mean age = 59.5 ± 20.1 years (95% CI: 54.7–64.2 years)) referred for CMR examination with concomitant irregular heart rate (defined by an RR interval coefficient of variation >10%) during scanning were prospectively enrolled. For each patient, two cine sequences were systematically acquired: first, the reference prospectively triggered multi-breath-hold Cineref sequence including a short-axis stack, one four-chamber slice, and a couple of two-chamber slices; second, an additional single breath-hold CSrt sequence providing the same slices as the reference technique. Two radiologists independently assessed ARA and image quality (overall, acquisition, and edge sharpness) for both techniques. Results: The mean heart rate was 71.8 ± 19.0 (SD) beat per minute (bpm) (95% CI: 67.4–76.3 bpm) and its coefficient of variation was 25.0 ± 9.4 (SD) % (95% CI: 22.8–27.2%). Acquisition was significantly faster with CSrt than with Cineref (Cineref: 556.7 ± 145.4 (SD) s (95% CI: 496.7–616.7 s); CSrt: 23.9 ± 7.9 (SD) s (95% CI: 20.6–27.1 s); p < 0.0001). A total of 599 pairs of cine slices were evaluated (median: 8 (range: 6–14) slices per patient). The mean proportion of ARA-impaired slices per patient was 85.9 ± 22.7 (SD) % using Cineref, but this was figure was zero using CSrt (p < 0.0001). The European CMR registry artifact score was lower with CSrt (median: 1 (range: 0–5)) than with Cineref (median: 3 (range: 0–3); p < 0.0001). Subjective image quality was higher in CSrt than in Cineref (median: 3 (range: 1–3) versus 2 (range: 1–4), respectively; p < 0.0001). In line, edge sharpness was higher on CSrt cine than on Cineref images (0.054 ± 0.016 pixel−1 (95% CI: 0.050–0.057 pixel−1) versus 0.042 ± 0.022 pixel−1 (95% CI: 0.037–0.047 pixel−1), respectively; p = 0.0001). Conclusion: Compressed sensing real-time cine drastically reduces arrhythmia-related artifacts and thus improves cine image quality in patients with arrhythmia.

18 March 2025 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
CGChristos Gkizas
Christos Gkizas
BLBenjamin Longère
Benjamin Longère
OSOlga Sliwicka
Olga Sliwicka
AMAimee Rodriguez Musso
Aimee Rodriguez Musso
GLGilles Lemesle
Gilles Lemesle
FPFRANCOIS PONTANA
FRANCOIS PONTANA

13 September 2025 in Diagnostic and Interventional Imaging
Verified
Journal Article
Open access
CGChristos Gkizas
Christos Gkizas
BLBenjamin Longère
Benjamin Longère
SBSaad Bechrouri
Saad Bechrouri
HRHelene Ridon
Helene Ridon
AMAimee Rodriguez Musso
Aimee Rodriguez Musso
FPFRANCOIS PONTANA
FRANCOIS PONTANA
The purpose of this study was to evaluate the diagnostic performance of myocardial extracellular volume (ECV) quantification using dual-source photon-counting detector computed tomography (PCCT) compared to cardiac magnetic resonance imaging (MRI) for assessing the severity of myocardial fibrosis in patients with hypertrophic cardiomyopathy (HCM). Patients with HCM due to sarcomere mutations underwent cardiac computed tomography angiography (CCTA) using a first-generation PCCT scanner, followed by comprehensive cardiac MRI. The CCTA protocol included a late iodine enhancement acquisition in spectral mode, 5 min after contrast media injection. ECV was calculated from the iodine ratio of the myocardium and blood pool on late iodine enhancement PCCT images. Cardiac MRI biomarkers included T1 mapping, ECV, and late gadolinium enhancement percentage (LGE). Diagnostic capabilities of PCCT were estimated using sensitivity, specificity, accuracy, interobserver agreement for myocardial fibrosis, area under the receiver operating characteristic curve (AUC) analyses for optimal thresholds, and correlations between tissue characteristics, functional capacity, and biomarkers. Thirty patients were retrospectively included. There were 22 men and eight women with a mean age of 59 ± 13.8 (standard deviation [SD]). The mean dose length product of late enhancement PCCT scanning was 105 ± 45 (SD) mGy.cm. No significant differences were found between global PCCT-derived ECV (30.0 ± 4.8 [SD] %) and MRI-derived ECV (30.62 ± 4.2 [SD] %) (P = 0.59). Linear regression revealed a strong segmental correlation between PCCT and MRI (basal, r = 0.89; mid-ventricular, r = 0.85; apical, r = 0.85; P < 0.001). An optimal PCCT-derived ECV threshold of 33.4 % allowed the diagnosis of LGE ≥ 15 % with 80 % sensitivity, 76 % specificity, and an AUC of 0.77, not significantly different from MRI-derived ECV (threshold 33.9 %; sensitivity, 80 %; specificity, 76 %, AUC, 0.80; P = 0.176). PCCT-derived ECV correlated with peak VO₂ (r = -0.76) and NT-proBNP levels (r = 0.59). PCCT-derived ECV shows promise for quantifying myocardial fibrosis in HCM, offering a valuable non-invasive alternative to cardiac MRI, especially for patients with contraindications or those requiring combined CCTA and myocardial assessment.

26 May 2016 in CardioVascular and Interventional Radiology
Verified
Journal Article
Closed access
PDF file
Dimitrios FilippiadisDimitrios Filippiadis
Dimitrios Filippiadis
CGChristos Gkizas
Christos Gkizas
CKC. Kostantos
C. Kostantos
AMArgyro Mazioti
Argyro Mazioti
LRL. Reppas
L. Reppas
Alexis  KelekisAlexis Kelekis
Alexis Kelekis

Verified
Journal Article
Open access
PDF file
BLBenjamin Longère
Benjamin Longère
CGChristos Gkizas
Christos Gkizas
ACAugustin Coisne
Augustin Coisne
LGLucas Grenier
Lucas Grenier
VSValentina Silvestri
Valentina Silvestri
FPFRANCOIS PONTANA
FRANCOIS PONTANA
Background and objective: Real-time compressed sensing cine (CSrt) provides reliable quantification for both ventricles but may alter image quality. The aim of this study was to assess image quality and the accuracy of left (LV) and right ventricular (RV) volumes, ejection fraction and mass quantifications based on a retrogated segmented compressed sensing 2D cine sequence (CSrg). Methods: Thirty patients were enrolled. Each patient underwent the reference retrogated segmented steady-state free precession cine sequence (SSFPref), the real-time CSrt cine and the segmented retrogated prototype CSrg sequence providing the same slices. Functional parameters quantification and image quality rating were performed on SSFPref and CSrg images sets. The edge sharpness, which is an estimate of the edge spread function, was assessed for the three sequences. Results: The mean scan time was: SSFPref = 485.4 ± 83.3 (SD) s (95% CI: 454.3–516.5) and CSrg = 58.3 ± 15.1 (SD) s (95% CI: 53.7–64.2) (p < 0.0001). CSrg subjective image quality score (median: 4; range: 2–4) was higher than the one provided by CSrt (median: 3; range: 2–4; p = 0.0008) and not different from SSFPref overall quality score (median: 4; range: 2–4; p = 0.31). CSrg provided similar LV and RV functional parameters to those assessed with SSFPref (p > 0.05). Edge sharpness was significantly better with CSrg (0.083 ± 0.013 (SD) pixel−1; 95% CI: 0.078–0.087) than with CSrt (0.070 ± 0.011 (SD) pixel−1; 95% CI: 0.066–0.074; p = 0.0004) and not different from the reference technique (0.075 ± 0.016 (SD) pixel−1; 95% CI: 0.069–0.081; p = 0.0516). Conclusions: CSrg cine provides in one minute an accurate quantification of LV and RV functional parameters without compromising subjective and objective image quality.