Yi-Chung Tung

Dr. Yi-Chung Tung

Research Center for Applied Sciences, Academia Sinica, Taipei 11529, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 October 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
YTYi-Chung Tung
Yi-Chung Tung
AHAmy Y. Hsiao
Amy Y. Hsiao
SASteven G. Allen
Steven G. Allen
YTYu-suke Torisawa
Yu-suke Torisawa
MHMitchell Ho
Mitchell Ho
STShuichi Takayama
Shuichi Takayama
Culture of cells as three-dimensional (3D) aggregates can enhance in vitro tests for basic biological research as well as for therapeutics development. Such 3D culture models, however, are often more complicated, cumbersome, and expensive than two-dimensional (2D) cultures. This paper describes a 384-well format hanging drop culture plate that makes spheroid formation, culture, and subsequent drug testing on the obtained 3D cellular constructs as straightforward to perform and adapt to existing high-throughput screening (HTS) instruments as conventional 2D cultures. Using this platform, we show that drugs with different modes of action produce distinct responses in the physiological 3D cell spheroids compared to conventional 2D cell monolayers. Specifically, the anticancer drug 5-fluorouracil (5-FU) has higher anti-proliferative effects on 2D cultures whereas the hypoxia activated drug commonly referred to as tirapazamine (TPZ) are more effective against 3D cultures. The multiplexed 3D hanging drop culture and testing plate provides an efficient way to obtain biological insights that are often lost in 2D platforms.

27 November 2007 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
DHDongeun Huh
Dongeun Huh
HFHideki Fujioka
Hideki Fujioka
YTYi-Chung Tung
Yi-Chung Tung
NFNobuyuki Futai
Nobuyuki Futai
RPRobert Paine
Robert Paine
STShuichi Takayama
Shuichi Takayama
We describe a microfabricated airway system integrated with computerized air–liquid two-phase microfluidics that enables on-chip engineering of human airway epithelia and precise reproduction of physiologic or pathologic liquid plug flows found in the respiratory system. Using this device, we demonstrate cellular-level lung injury under flow conditions that cause symptoms characteristic of a wide range of pulmonary diseases. Specifically, propagation and rupture of liquid plugs that simulate surfactant-deficient reopening of closed airways lead to significant injury of small airway epithelial cells by generating deleterious fluid mechanical stresses. We also show that the explosive pressure waves produced by plug rupture enable detection of the mechanical cellular injury as crackling sounds.

18 March 2019 in Molecular Cancer
Verified
Journal Article
Open access
PDF file
YWYueh-Shan Weng
Yueh-Shan Weng
HTHong-Yu Tseng
Hong-Yu Tseng
YCYen-An Chen
Yen-An Chen
PSPei-Chun Shen
Pei-Chun Shen
AHAushia Tanzih Al Haq
Aushia Tanzih Al Haq
HHHsin Ling Hsu
Hsin Ling Hsu
Triple-negative breast cancer (TNBC) is a poor prognostic breast cancer with the highest mutations and limited therapeutic choices. Cytokine networking between cancer cells and the tumor microenvironment (TME) maintains the self-renewing subpopulation of breast cancer stem cells (BCSCs) that mediate tumor heterogeneity, resistance and recurrence. Immunotherapy of those factors combined with targeted therapy or chemoagents may advantage TNBC treatment. We found that the oncogene Multiple Copies in T-cell Malignancy 1 (MCT-1/MCTS1) expression is a new poor-prognosis marker in patients with aggressive breast cancers. Overexpressing MCT-1 perturbed the oncogenic breast epithelial acini morphogenesis and stimulated epithelial-mesenchymal transition and matrix metalloproteinase activation in invasive TNBC cells, which were repressed after MCT-1 gene silencing. As mammary tumor progression was promoted by oncogenic MCT-1 activation, tumor-promoting M2 macrophages were enriched in TME, whereas M2 macrophages were decreased and tumor-suppressive M1 macrophages were increased as the tumor was repressed via MCT-1 knockdown. MCT-1 stimulated interleukin-6 (IL-6) secretion that promoted monocytic THP-1 polarization into M2-like macrophages to increase TNBC cell invasiveness. In addition, MCT-1 elevated the soluble IL-6 receptor levels, and thus, IL-6R antibodies antagonized the effect of MCT-1 on promoting M2-like polarization and cancer cell invasion. Notably, MCT-1 increased the features of BCSCs, which were further advanced by IL-6 but prevented by tocilizumab, a humanized IL-6R antibody, thus MCT-1 knockdown and tocilizumab synergistically inhibited TNBC stemness. Tumor suppressor miR-34a was induced upon MCT-1 knockdown that inhibited IL-6R expression and activated M1 polarization. The MCT-1 pathway is a novel and promising therapeutic target for TNBC.

1 June 2009 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JSJonathan W. Song
Jonathan W. Song
SCStephen P. Cavnar
Stephen P. Cavnar
AWAnn C. Walker
Ann C. Walker
KLKathryn E. Luker
Kathryn E. Luker
MGMudit Gupta
Mudit Gupta
STShuichi Takayama
Shuichi Takayama
The ability to properly model intravascular steps in metastasis is essential in identifying key physical, cellular, and molecular determinants that can be targeted therapeutically to prevent metastatic disease. Research on the vascular microenvironment has been hindered by challenges in studying this compartment in metastasis under conditions that reproduce in vivo physiology while allowing facile experimental manipulation. We present a microfluidic vasculature system to model interactions between circulating breast cancer cells with microvascular endothelium at potential sites of metastasis. The microfluidic vasculature produces spatially-restricted stimulation from the basal side of the endothelium that models both organ-specific localization and polarization of chemokines and many other signaling molecules under variable flow conditions. We used this microfluidic system to produce site-specific stimulation of microvascular endothelium with CXCL12, a chemokine strongly implicated in metastasis. When added from the basal side, CXCL12 acts through receptor CXCR4 on endothelium to promote adhesion of circulating breast cancer cells, independent of CXCL12 receptors CXCR4 or CXCR7 on tumor cells. These studies suggest that targeting CXCL12-CXCR4 signaling in endothelium may limit metastases in breast and other cancers and highlight the unique capabilities of our microfluidic device to advance studies of the intravascular microenvironment in metastasis.

1 June 2009 in Biomaterials
Verified
Journal Article
Closed access
AHAmy Y. Hsiao
Amy Y. Hsiao
YTYu-suke Torisawa
Yu-suke Torisawa
YTYi-Chung Tung
Yi-Chung Tung
SSSudha Sud
Sudha Sud
RTRussell Taichman
Russell Taichman
STShuichi Takayama
Shuichi Takayama

18 April 2010 in Nature Physics
Verified
Journal Article
Open access
PDF file
BMBobak Mosadegh
Bobak Mosadegh
CKChuan-Hsien Kuo
Chuan-Hsien Kuo
YTYi-Chung Tung
Yi-Chung Tung
YTYu-suke Torisawa
Yu-suke Torisawa
TBTommaso Bersano-Begey
Tommaso Bersano-Begey
STShuichi Takayama
Shuichi Takayama
A network of elastomeric microfluidic components that generates sequential and oscillating flows from a steady input flow should allow more autonomous on-chip control of lab-on-a-chip systems. A critical need for enhancing the usability and capabilities of microfluidic technologies is the development of standardized, scalable and versatile control systems1,2. Electronically controlled valves and pumps typically used for dynamic flow regulation, although useful, can limit convenience, scalability and robustness3,4,5. This shortcoming has motivated the development of device-embedded non-electrical flow-control systems. Existing approaches to regulate operation timing on-chip, however, still require external signals such as timed generation of fluid flow, bubbles, liquid plugs or droplets or an alteration of chemical compositions or temperature6,7,8,9,10,11,12,13,14,15,16. Here, we describe a strategy to provide device-embedded flow switching and clocking functions. Physical gaps and cavities interconnected by holes are fabricated into a three-layer elastomer structure to form networks of fluidic gates that can spontaneously generate cascading and oscillatory flow output using only a constant flow of Newtonian fluids as the device input. The resulting microfluidic substrate architecture is simple, scalable and should be applicable to various materials. This flow-powered fluidic gating scheme brings the autonomous signal processing ability of microelectronic circuits to microfluidics where there is the added diversity in current information of having distinct chemical or particulate species and richness in current operation of having chemical reactions and physical interactions.