Shuichi Takayama

Prof. Shuichi Takayama

orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 May 2022 in Nature Reviews Methods Primers
Verified
Journal Article
Open access
PDF file
CLChak Ming Leung
Chak Ming Leung
PHPim de Haan
Pim de Haan
KRKacey Ronaldson-Bouchard
Kacey Ronaldson-Bouchard
GKGe-Ah Kim
Ge-Ah Kim
JKJihoon Ko
Jihoon Ko
YTYi-Chin Toh
Yi-Chin Toh
Organs-on-chips (OoCs) are systems containing engineered or natural miniature tissues grown inside microfluidic chips. To better mimic human physiology, the chips are designed to control cell microenvironments and maintain tissue-specific functions. Combining advances in tissue engineering and microfabrication, OoCs have gained interest as a next-generation experimental platform to investigate human pathophysiology and the effect of therapeutics in the body. There are as many examples of OoCs as there are applications, making it difficult for new researchers to understand what makes one OoC more suited to an application than another. This Primer is intended to give an introduction to the aspects of OoC that need to be considered when developing an application-specific OoC. The Primer covers guiding principles and considerations to design, fabricate and operate an OoC, as well as subsequent assaying techniques to extract biological information from OoC devices. Alongside this is a discussion of current and future applications of OoC technology, to inform design and operational decisions during the implementation of OoC systems.

1 December 2012 in Journal of Controlled Release
Verified
Journal Article
Closed access
Geeta MehtaGeeta Mehta
Geeta Mehta
AHAmy Y. Hsiao
Amy Y. Hsiao
MIMarylou Ingram
Marylou Ingram
GLGary D. Luker
Gary D. Luker
STShuichi Takayama
Shuichi Takayama

21 October 2010 in The Analyst
Verified
Journal Article
Closed access
PDF file
YTYi-Chung Tung
Yi-Chung Tung
AHAmy Y. Hsiao
Amy Y. Hsiao
SASteven G. Allen
Steven G. Allen
YTYu-suke Torisawa
Yu-suke Torisawa
MHMitchell Ho
Mitchell Ho
STShuichi Takayama
Shuichi Takayama
Culture of cells as three-dimensional (3D) aggregates can enhance in vitro tests for basic biological research as well as for therapeutics development. Such 3D culture models, however, are often more complicated, cumbersome, and expensive than two-dimensional (2D) cultures. This paper describes a 384-well format hanging drop culture plate that makes spheroid formation, culture, and subsequent drug testing on the obtained 3D cellular constructs as straightforward to perform and adapt to existing high-throughput screening (HTS) instruments as conventional 2D cultures. Using this platform, we show that drugs with different modes of action produce distinct responses in the physiological 3D cell spheroids compared to conventional 2D cell monolayers. Specifically, the anticancer drug 5-fluorouracil (5-FU) has higher anti-proliferative effects on 2D cultures whereas the hypoxia activated drug commonly referred to as tirapazamine (TPZ) are more effective against 3D cultures. The multiplexed 3D hanging drop culture and testing plate provides an efficient way to obtain biological insights that are often lost in 2D platforms.

27 November 2007 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
DHDongeun Huh
Dongeun Huh
HFHideki Fujioka
Hideki Fujioka
YTYi-Chung Tung
Yi-Chung Tung
NFNobuyuki Futai
Nobuyuki Futai
RPRobert Paine
Robert Paine
STShuichi Takayama
Shuichi Takayama
We describe a microfabricated airway system integrated with computerized air–liquid two-phase microfluidics that enables on-chip engineering of human airway epithelia and precise reproduction of physiologic or pathologic liquid plug flows found in the respiratory system. Using this device, we demonstrate cellular-level lung injury under flow conditions that cause symptoms characteristic of a wide range of pulmonary diseases. Specifically, propagation and rupture of liquid plugs that simulate surfactant-deficient reopening of closed airways lead to significant injury of small airway epithelial cells by generating deleterious fluid mechanical stresses. We also show that the explosive pressure waves produced by plug rupture enable detection of the mechanical cellular injury as crackling sounds.

28 October 2004 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
WGWei Gu
Wei Gu
XZXiaoyue Zhu
Xiaoyue Zhu
NFNobuyuki Futai
Nobuyuki Futai
BCBrenda S. Cho
Brenda S. Cho
STShuichi Takayama
Shuichi Takayama
Computer-controlled microfluidics would advance many types of cellular assays and microscale tissue engineering studies wherever spatiotemporal changes in fluidics need to be defined. However, this goal has been elusive because of the limited availability of integrated, programmable pumps and valves. This paper demonstrates how a refreshable Braille display, with its grid of 320 vertically moving pins, can power integrated pumps and valves through localized deformations of channel networks within elastic silicone rubber. The resulting computerized fluidic control is able to switch among: ( i ) rapid and efficient mixing between streams, ( ii ) multiple laminar flows with minimal mixing between streams, and ( iii ) segmented plug-flow of immiscible fluids within the same channel architecture. The same control method is used to precisely seed cells, compartmentalize them into distinct subpopulations through channel reconfiguration, and culture each cell subpopulation for up to 3 weeks under perfusion. These reliable microscale cell cultures showed gradients of cellular behavior from C2C12 myoblasts along channel lengths, as well as differences in cell density of undifferentiated myoblasts and differentiation patterns, both programmable through different flow rates of serum-containing media. This technology will allow future microscale tissue or cell studies to be more accessible, especially for high-throughput, complex, and long-term experiments. The microfluidic actuation method described is versatile and computer programmable, yet simple, well packaged, and portable enough for personal use.

1 June 2009 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JSJonathan W. Song
Jonathan W. Song
SCStephen P. Cavnar
Stephen P. Cavnar
AWAnn C. Walker
Ann C. Walker
KLKathryn E. Luker
Kathryn E. Luker
MGMudit Gupta
Mudit Gupta
STShuichi Takayama
Shuichi Takayama
The ability to properly model intravascular steps in metastasis is essential in identifying key physical, cellular, and molecular determinants that can be targeted therapeutically to prevent metastatic disease. Research on the vascular microenvironment has been hindered by challenges in studying this compartment in metastasis under conditions that reproduce in vivo physiology while allowing facile experimental manipulation. We present a microfluidic vasculature system to model interactions between circulating breast cancer cells with microvascular endothelium at potential sites of metastasis. The microfluidic vasculature produces spatially-restricted stimulation from the basal side of the endothelium that models both organ-specific localization and polarization of chemokines and many other signaling molecules under variable flow conditions. We used this microfluidic system to produce site-specific stimulation of microvascular endothelium with CXCL12, a chemokine strongly implicated in metastasis. When added from the basal side, CXCL12 acts through receptor CXCR4 on endothelium to promote adhesion of circulating breast cancer cells, independent of CXCL12 receptors CXCR4 or CXCR7 on tumor cells. These studies suggest that targeting CXCL12-CXCR4 signaling in endothelium may limit metastases in breast and other cancers and highlight the unique capabilities of our microfluidic device to advance studies of the intravascular microenvironment in metastasis.