William Riddell

Dr. William Riddell

orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 June 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
RLRyan Loeh
Ryan Loeh
JEJess Everett
Jess Everett
WRWilliam Riddell
William Riddell
DCDouglas B. Cleary
Douglas B. Cleary
This study investigates the feasibility and benefits of transferring data between Autodesk Revit (used for building information modeling (BIM)) and BUILDER SMS (used for sustainable facility management (SFM)). Two data transfer methods were evaluated using a case study; one involved entirely manual data transfer, the other a combination of manual and automatic. Of the data transfer methods evaluated, the manual/automated hybrid was determined to be the best option, especially when regular updates are envisioned. The case study produced an enhanced BIM model that can be used to support sustainable facility management, called here an SFM-enhanced BIM model. An integration workflow is proposed for efficiently creating future SFM-enhanced BIM models. A focus group of facilities management professionals evaluated the case study BIM model. The focus group was most interested in the visualization capabilities—e.g., filtered views for condition assessments—and the ability to view the BIM model on a tablet/mobile device during on-site operation and maintenance activities.

1 September 2014 in Journal of Structural Engineering
Verified
Journal Article
Closed access
DRDaniel Reuther
Daniel Reuther
IBIan Baker
Ian Baker
AYAlexander Yetka
Alexander Yetka
DCDouglas B. Cleary
Douglas B. Cleary
WRWilliam Riddell
William Riddell
Results from a series of tests intended to study loss of pretension force in bolted assemblies are presented. The test matrix included ASTM A325 assemblies with various direct tension indicators (DTIs), some through-hardened and some not, as well as assemblies without direct tension indicators. Bolt length and diameter and grade of nut were also varied. Load losses were monitored for 42 days (1,000 h). However, load levels generally stabilized after 14 days. Pretension losses were linearly dependent on initial pretension and not affected by DTI or washer configuration. Bolt diameter and length did affect the magnitude of losses over time but not the general linear relationship with initial pretension.

1 November 2016 in Journal of Structural Engineering
Verified
Journal Article
Closed access
DCDouglas B. Cleary
Douglas B. Cleary
WRWilliam Riddell
William Riddell
NCNicolette Camishion
Nicolette Camishion
PDPatrick Downey
Patrick Downey
SMSean Marko
Sean Marko
TPThomas Panaro
Thomas Panaro
Fiber-reinforced resin (FRR) plates are being incorporated into structural joints to correct thermal bridging issues to create more energy-efficient buildings. The purpose of this study was to evaluate the behaviors of simple shear and moment connections that include FRR thermal barrier plates under service-loading conditions. Tests included two thicknesses and two grades of barrier plate. The shear connection tests showed that the coefficient of friction between steel and an as-received FRR plate was significantly lower than that of steel on steel. However, roughening the FRR plates by blasting with aluminum oxide increased the coefficient to nearly the same as or greater than steel on steel. In moment connections the presence of thermal barrier plates increased the joint rotation at the connection. A 25-mm (1-in.) thermal barrier plate increased the joint rotation by 10% compared to a joint without the barrier plate. The increase was 20% for a 50-mm (2-in.) plate. The thermal barrier plates did ...

17 January 2025 in Energies
Verified
Journal Article
Open access
PDF file
MZMahdiyeh Zafaranchi
Mahdiyeh Zafaranchi
WRWilliam Riddell
William Riddell
NCNicholas B. Chan
Nicholas B. Chan
ESElizabeth M. Saliba
Elizabeth M. Saliba
LLLuke Leung
Luke Leung
This study evaluates the energy consumption and embodied carbon emissions of various heat pump systems for an office building in Chicago, IL, U.S., over a 50-year lifespan, including the operation, manufacturing, and construction phases. The analyzed systems include air source heat pumps (ASHP) in Air to Air and Air to Water configurations, and ground source heat pumps (GSHP) in Soil to Air and Soil to Water configurations. A traditional HVAC system serves as the baseline for comparison. Advanced simulation tools, including Rhino, Grasshopper, TRACE 700, and One Click LCA, were used to identify the optimal HVAC system for sustainable building operations. Unlike prior studies focusing on GSHP versus traditional HVAC systems, this research directly compares GSHP and ASHP configurations, addressing a significant gap in the sustainable HVAC system design literature. The GSHP (Soil to Water) system demonstrated the lowest energy intensity at 100.8 kWh/m2·yr, a 41.8% improvement over the baseline, and the lowest total embodied carbon emissions at 3,882,164 kg CO2e. In contrast, the ASHP (Air to Air) system, while reducing energy consumption relative to the baseline, exhibited the highest embodied carbon emissions among the heat pump configurations due to its higher operational energy demands. The study highlights the significance of the operating phase in embodied carbon contributions. These findings emphasize the importance of a holistic design approach that considers both operational and embodied impacts to achieve sustainable building designs.

1 December 2024 in Journal of Cold Regions Engineering
Verified
Journal Article
Closed access
SAShahriar Abubakri
Shahriar Abubakri
WRWilliam Riddell
William Riddell
DCDouglas B. Cleary
Douglas B. Cleary
GLGilson R Lomboy
Gilson R Lomboy
DKDanielle Kennedy
Danielle Kennedy
BWBenjamin Watts
Benjamin Watts

12 January 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
JFJohn D. Foster
John D. Foster
JEJess Everett
Jess Everett
WRWilliam Riddell
William Riddell
This research focuses on data transfer from Sustainable Facility Management (SFM) to Building Information Modeling (BIM) applications—specifically BUILDER SMS to Autodesk Revit—where the BIM models are created for existing buildings. BIM models were created for ten existing buildings to support initial data transfer based on different object parameters: (a) alphanumeric identifier (five buildings); and (b) name (five buildings). The identifier is randomly assigned by BUILDER SMS. The name is derived from the cardinal direction for exterior components and room names for interior components. The comparison of the methods was accomplished by observing times to ensure data compatibility, complete Revit models, and transfer data from BUILDER SMS to Revit. The name method was faster regarding data compatibility, but no statistical evaluation could be made. The identifier method resulted in shorter model completion times, but the difference was not statistically significant. It was also faster for first-time data transfer, but, again, no statistical evaluation could be made. The difference in total effort required by the methods was not large. Furthermore, the first data transfer for either method can transfer the other parameter, i.e., a name-based data transfer can add the identifier to the Revit model and an identifier-based transfer can add the name. The name method may be slightly better than the identifier method because object names follow an intuitive and logical standard naming convention (specified in the SFM application). The process of ensuring data compatibility by manually entering object names may be less error-prone compared to manually entering alphanumeric identifiers; however, that was not demonstrated here as all of the resulting models were error-free regarding data transfer. The methods described provide useful insights for other SFM/BIM transfer scenarios, such as other applications and models generated during the design phase.