High-performance control systems (HPCSs), including active, hybrid, and semiactive control strategies, can perform over a wide excitation bandwidth and are therefore good candidates for multihazard mitigation. However, the number of HPCS applications in the field is very limited. This is likely due to the perceived higher costs of installation, maintenance, possible malfunction, and lack of tools to financially justify their implementation. Such financial justifications could be conducted through life-cycle cost (LCC) analysis, but would result in a computationally demanding task due to the very large number of simulations required given the large number of uncertainties. In this paper, two sets of methods for conducting LCC analyses are compared and their performance is assessed as a function of LCC estimation accuracy and computational requirements. The first set is based on deterministic scenarios and on the simulation of all possible scenarios; it is termed “what-if analysis.” Variations of the what-if method are investigated, where the simulations are conducted only for the most likely scenarios, termed “most-likely (ML)” analysis. The second set is based on stochastic scenarios and on Monte-Carlo (MC) analysis. Variations of the MC method are investigated, one based on the coefficient of variation of output data and one proposed by the authors based on the convergence of the estimated costs, termed bounded MC. A demonstration of the LCC analysis methodology is conducted where an HPCS is used for the mitigation of seismic-induced vibrations on a five-story structure. Uncertainties under consideration include sensor failure, mechanical wear, tear, and seismic events. Results are compared against the uncontrolled structure and a passive viscous strategy, and demonstrate that (1) the LCC methodology can be used to financially justify the utilization on an HPCS; and (2) the bounded MC method leads to accurate cost estimations using a lower number of simulations.
1 December 2020 in ASCE-ASME Journal of Risk and Uncertainty in Engineering Systems, Part A: Civil Engineering
Performance-based design (PBD) is becoming a benchmark approach for design and performance assessment of civil structures because it facilitates communication between stakeholders and design professionals with decision metrics such as economic losses, downtime, and probabilistic cost functions. However, to reliably estimate the response of a building, it is necessary to consider uncertainties in structural parameters and external load characteristics, which makes the probabilistic assessment phase of PBD time consuming and often impractical. In wind-excited tall buildings, this aspect is combined with the long duration of typical wind events (in the order of hours) and the time required to conduct a single numerical simulation, further increasing the computational demand of the uncertainty analysis. As a solution, this paper presents a novel multiple-surrogate models framework for the probabilistic assessment of wind-excited tall buildings. In the proposed framework, the structural system is decomposed into a set of subsystems and multiple-surrogate models are used to map the uncertain building dynamic properties and wind load characteristics to its structural response, expressed in terms of peak floor acceleration and maximum story drift ratio. The proposed approach is demonstrated on a 40-story building, located in Boston, Massachusetts, and exposed to synthetic wind load time histories. The accuracy of the multiple-surrogate models to estimate the structural response of the building is first evaluated. Then, an application of the multiple-surrogate models to the cost assessment of the case study building is presented to demonstrate the capabilities of the proposed approach to probabilistically assess the performance of a structure and its potential integration in PBD. Results show that using the multiple-surrogate models framework represents a viable solution to handle the large dimensional probabilistic assessment of wind-excited tall buildings under uncertainties in dynamic properties and wind load characteristics.
15 January 2021 in The Structural Design of Tall and Special Buildings
High-performance control systems (HPCS) are sophisticated vibration-mitigation devices that include active, semiactive, and hybrid systems. HPCS leverage feedback mechanisms to dynamically adjust the damping force in response to motion, offering a good mitigation performance over a wide excitation bandwidth. These damping systems are attractive for multihazard mitigation of civil structures. However, the application of HPCS necessitates the design and integration of a closed-loop control system that can be susceptible to local failure or reduction in performance in the form of, for example, malfunctions of HPCS components, noisy measurements, wear, aging, and power unavailability. It follows that these sources of uncertainties may cause concerns and impede the wide acceptability and deployment of HPCS. A solution is to enhance the robustness of the closed-loop configuration through, for example, added redundancies and/or more robust, yet more expensive, components. In this paper, a Kriging-based design procedure is presented enabling the robust design of closed-loop control systems. The design procedure consists of constructing a Kriging surrogate that maps uncertainties to structural performance, and using that surrogate to identify the most influential sources of uncertainties. After, these identified uncertainties are made more robust in order to decrease the variance in the HPCS performance over the lifetime of the structure. The performance of the HPCS is directly quantified through a life cycle cost analysis to obtain probability distributions on the expected financial impacts. The proposed procedure is demonstrated on a numerically simulated 39-story structure exposed to wind loads. Uncertainties in both the HPCS configuration (i.e., damping devices and sensors) and external load are considered. Results demonstrate that the proposed framework can be used to substantially improve the robustness of the closed-loop system. Also, through a comparison against a robust passive-viscous case, it is shown that robustly designed HPCS significantly outperform a passive system in terms of vibration mitigation and life cycle costs.