Liang Cao

Liang Cao

Auto-generated profile, based on publicly available information

Liang Cao

Department of Civil Engineering University of Mississippi Mississippi USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2015 in Shock and Vibration
Verified
Journal Article
Open access
PDF file
Simon LaflammeSimon Laflamme
Simon Laflamme
LCLiang Cao
Liang Cao
Eleni ChatziEleni Chatzi
Eleni Chatzi
Filippo UbertiniFilippo Ubertini
Filippo Ubertini
Structural health monitoring of large systems is a complex engineering task due to important practical issues. When dealing with large structures, damage diagnosis, localization, and prognosis necessitate a large number of sensors, which is a nontrivial task due to the lack of scalability of traditional sensing technologies. In order to address this challenge, the authors have recently proposed a novel sensing solution consisting of a low-cost soft elastomeric capacitor that transduces surface strains into measurable changes in capacitance. This paper demonstrates the potential of this technology for damage detection, localization, and prognosis when utilized in dense network configurations over large surfaces. A wind turbine blade is adopted as a case study, and numerical simulations demonstrate the effectiveness of a data-driven algorithm relying on distributed strain data in evidencing the presence and location of damage, and sequentially ranking its severity. Numerical results further show that the soft elastomeric capacitor may outperform traditional strain sensors in damage identification as it provides additive strain measurements without any preferential direction. Finally, simulation with reconstruction of measurements from missing or malfunctioning sensors using the concepts of virtual sensors and Kriging demonstrates the robustness of the proposed condition assessment methodology for sparser or malfunctioning grids.

1 July 2015 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
LCLiang Cao
Liang Cao
Austin DowneyAustin Downey
Austin Downey
Simon LaflammeSimon Laflamme
Simon Laflamme
DTDouglas Taylor
Douglas Taylor
JRJames Ricles
James Ricles

1 April 2016 in Engineering Structures
Verified
Journal Article
Closed access
Austin DowneyAustin Downey
Austin Downey
LCLiang Cao
Liang Cao
Simon LaflammeSimon Laflamme
Simon Laflamme
DTDouglas Taylor
Douglas Taylor
JRJames Ricles
James Ricles

1 November 2020 in Journal of Sound and Vibration
Verified
Journal Article
Closed access
LCLiang Cao
Liang Cao
YGYongqiang Gong
Yongqiang Gong
Filippo UbertiniFilippo Ubertini
Filippo Ubertini
HWHao Wu
Hao Wu
ACAn Chen
An Chen
Simon LaflammeSimon Laflamme
Simon Laflamme

1 December 2016 in Journal of Structural Engineering
Verified
Journal Article
Closed access
LCLiang Cao
Liang Cao
SLSimon Laflamme
Simon Laflamme
DTDouglas Taylor
Douglas Taylor
JRJames Ricles
James Ricles
This paper investigates the performance of a novel semiactive damping device at mitigating nonsimultaneous multihazard loads. The device, termed modified friction device (MFD), has been previously proposed by the authors. It consists of a variable friction system based on automotive drum brake technology. The device has been demonstrated in a laboratory environment, and its dynamic behavior has been modeled. This model is used to conduct numerical simulations on two representative structures, one short building located in Japan and the other tall building located in Boston, MA. Simulated hazards include wind, blast, and seismic loads. Various control cases are considered, including semiactive control under five different sets of control weights, and passive viscous and passive friction to benchmark performance. Results show that the semiactive control cases outperforms all of the other cases for the vast majority of hazards and performance indices, provided that the right control weights are utilized.

1 February 2020 in Journal of Engineering Mechanics
Verified
Journal Article
Closed access
LMLaura Micheli
Laura Micheli
LCLiang Cao
Liang Cao
Simon LaflammeSimon Laflamme
Simon Laflamme
AAAlice Alipour
Alice Alipour
High-performance control systems (HPCSs), including active, hybrid, and semiactive control strategies, can perform over a wide excitation bandwidth and are therefore good candidates for multihazard mitigation. However, the number of HPCS applications in the field is very limited. This is likely due to the perceived higher costs of installation, maintenance, possible malfunction, and lack of tools to financially justify their implementation. Such financial justifications could be conducted through life-cycle cost (LCC) analysis, but would result in a computationally demanding task due to the very large number of simulations required given the large number of uncertainties. In this paper, two sets of methods for conducting LCC analyses are compared and their performance is assessed as a function of LCC estimation accuracy and computational requirements. The first set is based on deterministic scenarios and on the simulation of all possible scenarios; it is termed “what-if analysis.” Variations of the what-if method are investigated, where the simulations are conducted only for the most likely scenarios, termed “most-likely (ML)” analysis. The second set is based on stochastic scenarios and on Monte-Carlo (MC) analysis. Variations of the MC method are investigated, one based on the coefficient of variation of output data and one proposed by the authors based on the convergence of the estimated costs, termed bounded MC. A demonstration of the LCC analysis methodology is conducted where an HPCS is used for the mitigation of seismic-induced vibrations on a five-story structure. Uncertainties under consideration include sensor failure, mechanical wear, tear, and seismic events. Results are compared against the uncontrolled structure and a passive viscous strategy, and demonstrate that (1) the LCC methodology can be used to financially justify the utilization on an HPCS; and (2) the bounded MC method leads to accurate cost estimations using a lower number of simulations.