The detection of cancer biomarkers has recently become an established method for the early diagnosis of cancer. The sensitive analysis of specific biomarkers can also be clinically applied for the determination of response to treatment and monitoring of disease progression. Because of the ultra-low concentration of cancer biomarkers in body fluids, diagnostic tools need to be highly sensitive and specific. Conducting polymers (CPs) are particularly known to exhibit numerous features that enable them to serve as excellent materials for the immobilization of biomolecules and the facilitation of electron transfer. Their large surface area, porosity, and the presence of functional groups provide CPs with binding sites suitable for capturing biomarkers, in addition to their sensitive and easy detection. The aim of this review is to present a comprehensive summary of the available electrochemical biosensors based on CPs and their composites for the ultrasensitive detection of selected cancer biomarkers. We have categorized the study based on different types of targeted biomarkers such as DNAs, miRNAs, proteins, enzymes, neurotransmitters and whole cancer cells. The sensitivity of their detection is enhanced by the presence of CPs, providing a limit of detection as low as 0.5 fM (for miRNA) and 10 cells (for the detection of cancer cells). The methods of multiplex biomarker detection and cell capture are indicated as the most promising category, since they furnish more accurate and reliable results. Ultimately, we discuss the available CP-based electrochemical sensors and promising approaches for facilitating cancer diagnosis and treatment.
The aspiration to interact living cells with electronics challenges researchers to develop materials working at the interface of these two distinct environments. A successful interfacing coating should exhibit both biocompatibility and desired functionality of a bio-integrated device. Taking into account biodiversity, the tissue interface should be fine-tuned to the specific requirements of the bioelectronic systems. In this study, we pointed to electrochemical doping of conducting polymers as a strategy enabling the efficient manufacturing of interfacing platforms, in which features could be easily adjusted. Consequently, we fabricated conducting films based on a poly(3,4-ethylenedioxythiophene) (PEDOT) matrix, with properties modulated through doping with selected ions: PSS− (poly(styrene sulfonate)), ClO4− (perchlorate), and PF6− (hexafluorophosphate). Striving to extend the knowledge on the relationships governing the dopant effect on PEDOT films, the samples were characterized in terms of their chemical, morphological, and electrochemical properties. To investigate the impact of the materials on attachment and growth of cells, rat neuroblastoma B35 cells were cultured on their surface and analyzed using scanning electron microscopy and biological assays. Eventually, it was shown that through the choice of a dopant and doping conditions, PEDOT-based materials can be efficiently tuned with diversified physicochemical properties. Therefore, our results proved electrochemical doping of PEDOT as a valuable strategy facilitating the development of promising tissue interfacing materials with characteristics tailored as required.
Vascular regeneration is a complex process, additionally limited by the low regeneration potential of blood vessels. Hence, current research is focused on the design of artificial materials that combine biocompatibility with a certain rate of biodegradability and mechanical robustness. In this paper, we have introduced a scaffold material made of poly(L-lactide-co-glycolide)/poly(isosorbide sebacate) (PLGA/PISEB) fibers fabricated in the course of an electrospinning process, and confirmed its biocompatibility towards human umbilical vein endothelial cells (HUVEC). The resulting material was characterized by a bimodal distribution of fiber diameters, with the median of 1.25 µm and 4.75 µm. Genotyping of HUVEC cells collected after 48 h of incubations on the surface of PLGA/PISEB scaffolds showed a potentially pro-angiogenic expression profile, as well as anti-inflammatory effects of this material. Over the course of a 12-week-long hydrolytic degradation process, PLGA/PISEB fibers were found to swell and disintegrate, resulting in the formation of highly developed structures resembling seaweeds. It is expected that the change in the scaffold structure should have a positive effect on blood vessel regeneration, by allowing cells to penetrate the scaffold and grow within a 3D structure of PLGA/PISEB, as well as stabilizing newly-formed endothelium during hydrolytic expansion.
Advancement in polymer technologies, facilitated predominantly through chemical engineering approaches or through the identification and utilization of novel renewable resources, has been a steady focus of biomaterials research for the past 50 years. Aliphatic polyesters have been exploited in numerous biomedical applications including the formulation of soft-tissue sutures, bone fixation devices, cardiovascular stents etc. Biomimetic ‘soft’ polymer formulations are of interest in the design of biological interfaces and specifically, in the development of implantable neuroelectrode systems intended to interface with neural tissues. Critically, soft polymer formulations have been shown to address the challenges associated with the disregulation of mechanotransductive processes and micro-motion induced inflammation at the electrode/tissue interface. In this study, a polyester-based poly(ε-decalactone)/silver nanowire (EDL:Ag) composite was investigated as a novel electrically active biomaterial with neural applications. Neural interfaces were formulated through spin coating of a polymer/nanowire formulation onto the surface of a Pt electrode to form a biocompatible EDL matrix supported by a percolated network of silver nanowires. As-formed EDL:Ag composites were characterized by means of infrared spectroscopy, scanning electron microscopy and electrochemical methods, with their cytocompatibility assessed using primary cultures of a mixed neural population obtained from the ventral mesencephalon of Sprague-Dawley rat embryos. Electrochemical characterization of various EDL:Ag composites indicated EDL:Ag 10:1 as the most favourable formulation, exhibiting high charge storage capacity (8.7 ± 1.0 mC/cm2), charge injection capacity (84.3 ± 1.4 μC/cm2) and low impedance at 1 kHz (194 ± 28 Ω), outperforming both pristine EDL and bare Pt electrodes. The in vitro biological evaluation showed that EDL:Ag supported significant neuron viability in culture and to promote neurite outgrowth, which had the average length of 2300 ± 6 μm following 14 days in culture, 60% longer than pristine EDL and 120% longer than bare Pt control substrates. EDL:Ag nanocomposites are shown to serve as robust neural interface materials, possessing favourable electrochemical characteristics together with high neural cytocompatibility.