In space application, hybrid pixel detectors of the Timepix family have been considered mainly for the measurement of radiation levels and dosimetry in low earth orbits. Using the example of the Space Application of Timepix Radiation Monitor (SATRAM), we demonstrate the unique capabilities of Timepix-based miniaturized radiation detectors for particle separation. We present the incident proton energy spectrum in the geographic location of SAA obtained by using Bayesian unfolding of the stopping power spectrum measured with a single-layer Timepix. We assess the measurement stability and the resiliency of the detector to the space environment, thereby demonstrating that even though degradation is observed, data quality has not been affected significantly over more than 10 years. Based on the SATRAM heritage and the capabilities of the latest-generation Timepix series chips, we discuss their applicability for use in a compact magnetic spectrometer for a deep space mission or in the Jupiter radiation belts, as well as their capability for use as single-layer X- and -ray polarimeters. The latter was supported by the measurement of the polarization of scattered radiation in a laboratory experiment, where a modulation of 80% was found.
1 April 2016 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Funded by the European Space Agency, a miniaturized radiation monitor (MIRAM) is being developed in collaboration of the Institute for Experimental and Applied Physics, Czech Technical University in Prague and ADVACAM s.r.o. in Prague. Within a small, low power consumption and inexpensive unit, this tool provides measurement of the deposited dose and flux estimation for electrons and protons separately to the spacecraft it is attached to. The planned device will integrate a direct-converting pixel detector of the Timepix family (300-1000 µm thick sensor, 256 x 256 pixels, pixel pitch 55 µm), combined with four diodes, providing low power mode and coincidence measurements. Presented are the strategy for the particle-type identification and results from simulations of the detector response for electrons and protons. The strategy and design are based on the experience gained from the investigation of the data received from the Space Application of the Timepix Radiation Monitor (SATRAM) within the last five years. The proficiency of both is analysed using data from MC simulations in Geant4.
Inelastic neutron scattering from 56Fe was studied at the nELBE time-of-flight facility. The incoming neutron energy ranges from 100 keV to 10 MeV in the fast neutron spectrum, where high precision nuclear data are needed. A detector setup has been installed to investigate the γ-ray angular distributions. It contains five HPGe and five LaBr3 detectors positioned at 30, 55, 90, 125 and 150 degrees relative to the beam axis. The intrinsic and the neutron induced background from the setup was subtracted by cyclical measurements with and without the natural Fe-target. Corrections for extended source efficiency and gamma-self-absorption, inside the target, were done using GEANT4 simulations. The angular distributions measured with the HPGe detectors are compared with earlier data. High neutron energy resolution up to a few keV was obtained with the LaBr3 detectors due to their much better time resolution.