In space application, hybrid pixel detectors of the Timepix family have been considered mainly for the measurement of radiation levels and dosimetry in low earth orbits. Using the example of the Space Application of Timepix Radiation Monitor (SATRAM), we demonstrate the unique capabilities of Timepix-based miniaturized radiation detectors for particle separation. We present the incident proton energy spectrum in the geographic location of SAA obtained by using Bayesian unfolding of the stopping power spectrum measured with a single-layer Timepix. We assess the measurement stability and the resiliency of the detector to the space environment, thereby demonstrating that even though degradation is observed, data quality has not been affected significantly over more than 10 years. Based on the SATRAM heritage and the capabilities of the latest-generation Timepix series chips, we discuss their applicability for use in a compact magnetic spectrometer for a deep space mission or in the Jupiter radiation belts, as well as their capability for use as single-layer X- and -ray polarimeters. The latter was supported by the measurement of the polarization of scattered radiation in a laboratory experiment, where a modulation of 80% was found.
The present manuscript describes a comprehensive characterization of a novel highly segmented 5 mm CZT sensor attached to Timepix3. First, the sensor’s IV curve was measured and basic sensor characterization was done with laboratory γ-radiation sources. The sensor resistivity was determined to be (0.155± 0.02) GOhm · cm. The sensor showed decent homogeneity, both for the per-pixel count rate and electron mobility-lifetime product μeτe. The latter was measured to be = 1.3 × 10−3 cm2/V with a standard deviation σ = 0.4 × 10−3 cm2/V describing the dispersion of values for different pixels. The basic sensor characterization is complemented by measurements at grazing angle in a 120 GeV/c at the CERN’s Super Proton Synchrotron. The penetrating nature of these particles together with the pixelation of the sensor allows for a determination of the charge collection efficiency (CCE), as well as charge carrier drift properties (drift times, lateral charge cloud expansion) as a function of the interaction depths in the sensor. While CCE drops by 30%–40% towards the cathode side of the sensor, from the drift time dependency on interaction depth, the electron mobility μe was extracted to be (944.8 ± 1.3) cm2/V/s and τe = (1.38 ± 0.31) μs. The spectroscopic performance was assessed in photon fields and extracted from energy loss spectra measured at different angles in the pion beam. While at photon energies below 120 keV incomplete charge collection leads to an underestimation of the photon energy when irradiated from the front-side, at higher energies the relative energy resolution was found to be ∼4.5%, while a relative energy resolution of ∼7.5% was found for the particle energy loss spectra. It is shown that the drift time information can be used to reconstruct particle interactions in the sensor in 3D, providing a spatial resolution of σxyz = 241 μm within the sensor volume and a particle trajectory measurement precision Δxyz = 100 μm, at a distance of 1 m from the sensor. We demonstrate by measurement with a 22Na source, that the energy resolution combined with the 3D reconstruction allows for detection of γ-ray source location and polarity using Compton scattering within the sensor (Compton camera and scatter polarimeter).
The present work demonstrates the usage of a Timepix3 with a 1 mm thick silicon sensor as a scattering polarimeter with simultaneous Compton-camera imaging. For this purpose, laboratory experiments were designed where the detector was placed at different scattering angles with respect to a plastic target that is irradiated with X-rays from a Hamamatsu microfocus tube (tube voltage 75 kV, tube current 60 µA). Photons scattered in the target at 90∘ are almost 100 % linearly polarized. Measurements in an energy range of 32.5–67.5 keV showed modulation factors above 70 %. Simulations of 100 % linearly polarized beams showed modulation factors μ100 > 77 % in an energy range of 45–80 keV. The efficiency of detection has a maximum above 0.13 % at 45–50 keV. We implemented the origin ensemble with resolution recovery (OE-RR) algorithm for Compton camera imaging. The full width at half maximum (FWHM) of the image of 16–21∘ was achieved.
This work presents a simulation study of a Timepix3 telescope composed of nine detectors for use as a Compton scatter polarimeter in the energy range of 35–100 keV. Four detectors carry 1 mm thick silicon (Si) sensors and five detectors carry 1 mm thick cadmium telluride (CdTe) sensors. The modulation factor for 100% linearly polarized X-ray beams was found to be in the energy range of 55–80 keV. The quality factor of the polarimeter has its maximum 12.8% at the energy 75 keV. The comparison of quality factors and the calculations of a hypothetical observation of the Crab nebula show that this multilayer Timepix3 approach is competitive with contemporary X-ray polarimeters.
The current interest in lunar exploration led by the Artemis program is pushing scientists to search for lunar water deposits directly on the surface of the Moon, using small robotic rovers. The Institute of Experimental and Applied Physics, Czech Technical University, Prague (IEAP CTU), is developing a miniature Timepix3-based detector called Neutron HardPix, which is capable of mapping water deposits using non-invasive detection of neutrons created underground by cosmic rays and thermalized by hydrogen. This neutron spectrometer measures count rate variations in thermal, epithermal and fast neutrons attributed to hydrogen abundance in the lunar subsurface, while monitoring cosmic radiation as a natural source of neutrons. Neutron HardPix is based on the miniature (<0.1 U, 130 g) radiation monitor HardPix, and has significant space heritage.
In space application, hybrid pixel detectors of the Timepix family have been considered mainly for measurement of radiation levels and radiation dosimetry in low earth orbits. By the example of the Space Application of Timepix Radiation Monitor (SATRAM), we demonstrate the unique capabilities of Timepix-based miniaturized radiation detectors for particle separation. Using a novel method for proton spectrum reconstruction, we were able to measure the spectrum of protons trapped in the inner Van-Allen radiation belt, for the first time with a single-layer detector. We assess the measurement stability and the resiliency of the detector to the space environment demonstrating that, even though degradation is observed, data quality has not been affected significantly over more than 10 years. Based on the SATRAM heritage and the capabilities of the latest-generation Timepix-series chips, we discuss their applicability for use in a compact magnetic spectrometer for deep-space mission or in the high radiation environment of the Jupiter radiation belts, and their capability for use as single-layer X- and γ-ray polarimeter. The latter was supported by measurement of the polarization of scattered radiation in a laboratory experiment, where a modulation of 80% was found.