Marco Armbruster

Dr. Marco Armbruster


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 July 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
SSSonja Schwarz
Sonja Schwarz
DCDirk Clevert
Dirk Clevert
MIMichael Ingrisch
Michael Ingrisch
TGThomas Geyer
Thomas Geyer
VSVincent Schwarze
Vincent Schwarze
MAMarco Armbruster
Marco Armbruster
Background: To evaluate the diagnostic accuracy of quantitative perfusion parameters in contrast-enhanced ultrasound to differentiate malignant from benign liver lesions. Methods: In this retrospective study 134 patients with a total of 139 focal liver lesions were included who underwent contrast enhanced ultrasound (CEUS) between 2008 and 2018. All examinations were performed by a single radiologist with more than 15 years of experience using a second-generation blood pool contrast agent. The standard of reference was histopathology (n = 60), MRI or CT (n = 75) or long-term CEUS follow up (n = 4). For post processing regions of interests were drawn both inside of target lesions and the liver background. Time–intensity curves were fitted to the CEUS DICOM dataset and the rise time (RT) of contrast enhancement until peak enhancement, and a late-phase ratio (LPR) of signal intensities within the lesion and the background tissue, were calculated and compared between malignant and benign liver lesion using Student’s t-test. Quantitative parameters were evaluated with respect to their diagnostic accuracy using receiver operator characteristic curves. Both features were then combined in a logistic regression model and the cumulated accuracy was assessed. Results: RT of benign lesions (14.8 ± 13.8 s, p = 0.005), and in a subgroup analysis, particular hemangiomas (23.4 ± 16.2 s, p < 0.001) differed significantly to malignant lesions (9.3 ± 3.8 s). The LPR was significantly different between benign (1.59 ± 1.59, p < 0.001) and malignant lesions (0.38 ± 0.23). Logistic regression analysis with RT and LPR combined showed a high diagnostic accuracy of quantitative CEUS parameters with areas under the curve of 0.923 (benign vs. malignant) and 0.929 (hemangioma vs. malignant. Conclusions: Quantified CEUS parameters are helpful to differentiate malignant from benign liver lesions, in particular in case of atypical hemangiomas.

3 July 2018 in BMC Medical Imaging
Verified
Journal Article
Open access
PDF file
FSFranziska Schöppe
Franziska Schöppe
WSWieland H. Sommer
Wieland H. Sommer
FSFlorian Florian Schmidutz
Florian Florian Schmidutz
DPDominik Pförringer
Dominik Pförringer
MAMarco Armbruster
Marco Armbruster
NSNora N. Sommer
Nora N. Sommer
To analyse structured and free text reports of shoulder X-ray examinations evaluating the quality of reports and potential contributions to clinical decision-making. We acquired both standard free text and structured reports of 31 patients with a painful shoulder without history of previous trauma who received X-ray exams. A template was created for the structured report based on the template ID 0000154 (Shoulder X-ray) from radreport.org using online software with clickable decision trees with concomitant generation of structured semantic reports. All reports were evaluated regarding overall quality and key features: content, information extraction and clinical relevance. Two experienced orthopaedic surgeons reviewed and rated structured and free text reports of 31 patients independently. The structured reports achieved significantly higher median ratings in all key features evaluated (P < 0.001), including facilitation of information extraction (P < 0.001) and better contribution to subsequent clinical decision-making (P < 0.001). The overall quality of structured reports was significantly higher than in free text report (P < 0.001). A comprehensive structured template may be a useful tool to assist in clinical decision-making and is, thus, recommended for the reporting of degenerative changes regarding X-ray examinations of the shoulder.

30 January 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
SNSandra Niedermeier
Sandra Niedermeier
RWRebecca Wania
Rebecca Wania
ALAlina Lampart
Alina Lampart
RSRobert Stahl
Robert Stahl
Christoph Gregor TrummChristoph Gregor Trumm
Christoph Gregor Trumm
VPVera Pedersen
Vera Pedersen
Background: Computed tomography (CT) is commonly used in trauma care, with increasing implementation during the emergency work-up of elderly patients with low-energy falls (LEF). The prevalence of incidental findings (IFs) resulting from CT imaging and requiring down-stream actions in this patient cohort is unknown. We have investigated the prevalence and urgency of IFs from emergency CT examinations in these patients. Methods: A total of 2871 patients with LEF and emergency CT examinations were consecutively included in this retrospective cohort study. The primary endpoint was the prevalence of IFs; the secondary endpoint was their urgency. Results: The median age was 82 years (64.2% were women). IFs were identified in 73.9% of patients, with an average of 1.6 IFs per patient. Of all IFs, 16.4% were classified as urgent or relevant, predominantly in the abdomen, chest and neck. Increasing age was associated with the prevalence of an IF (odds ratio: 1.053, 95% confidence interval: 1.042–1.064). Significantly more IFs were found in female patients (75.2% vs. 71.5%). Conclusion: IFs resulting from CT examinations of the elderly are frequent, but in more than 8 out of 10, they are harmless or currently asymptomatic. For the benefit of an accurate diagnosis of traumatic lesions, concerns about IFs with respect to disease burden, further work-up and resource utilisation might be disregarded.

27 December 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
TGThomas Geyer
Thomas Geyer
DCDirk Clevert
Dirk Clevert
SSSonja Schwarz
Sonja Schwarz
PRPaul Reidler
Paul Reidler
Sebastian GassenmaierSebastian Gassenmaier
Sebastian Gassenmaier
MAMarco Armbruster
Marco Armbruster
Background: Contrast-enhanced ultrasound (CEUS) allows for dynamic analysis of vascularization patterns of unclear hepatic lesions. Our study aimed to evaluate the diagnostic performance of CEUS for further characterizing suspicious liver lesions by comparing findings from CEUS examinations with corresponding histopathology. Methods: Between 2005 and 2016, 160 patients with unclear liver lesions underwent CEUS followed by liver biopsy. All examinations were performed by an experienced consultant radiologist (EFSUMB Level 3) and included native B-mode ultrasound, Color Doppler, and CEUS. A second-generation blood pool contrast agent was applied for CEUS. Results: CEUS was successfully performed in all patients without occurrence of any adverse side effects. CEUS showed a sensitivity of 94.5%, a specificity of 70.6%, a true positive rate of 87.3%, and a true negative rate of 85.7% compared to histopathological results as the reference standard. Conclusions: CEUS represents a safe imaging modality with a high diagnostic accuracy in assessing both—benign and malignant—liver lesions compared to corresponding histopathological results.

28 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
MAMarco Armbruster
Marco Armbruster
MGMarkus Otto Guba
Markus Otto Guba
JAJoachim Andrassy
Joachim Andrassy
MRMarkus Rentsch
Markus Rentsch
VSVincent Schwarze
Vincent Schwarze
HKHarald Kramer
Harald Kramer
Background: The aim of this paper was to assess and compare the accuracy of common magnetic resonance imaging (MRI) pulse sequences in measuring the lesion sizes of hepatocellular carcinomas (HCCs) with respect to the Milan criteria and histopathology as a standard of reference. Methods: We included 45 patients with known HCC who underwent contrast-enhanced MRI of the liver prior to liver transplantation or tumor resection. Tumor size was assessed pathologically for all patients. The MRI protocol contained axial T2-weighted images as well as T1-weighted imaging sequences before and after application of Gd-EOB-DTPA. Tumor diameters, the sharpness of lesions, and the presence of artifacts were evaluated visually on all available MRI sequences. MRI measurements and pathologically assessed tumor dimensions were correlated using Pearson’s correlation coefficient and Bland–Altman plots. The rate of misclassifications following Milan criteria was assessed. Results: The mean absolute error (in cm) of MRI size measurements in comparison to pathology was the smallest for the hepatobiliary phase T1-weighted acquisition (0.71 ± 0.70 cm, r = 0.96) and largest for the T2w turbo-spin-echo (TSE) sequence (0.85 ± 0.78 cm, r = 0.94). The misclassification rate regarding tumor size under the Milan criteria was lowest for the T2w half-Fourier acquisition single-shot turbo spin-echo sequence and the hepatobiliary phase T1w acquisition (each 8.6%). The highest rate of misclassification occurred in the portal venous phase T1w acquisition and T2w TSE sequence (each 14.3%). Conclusions: The hepatobiliary phase T1-weighted acquisition seems to be most accurate among commonly used MRI sequences for measuring HCC tumor size, resulting in low rates of misclassification with respect to the Milan criteria.

1 March 2020 in Der Radiologe
Verified
Journal Article
Closed access
PDF file
MAMarco Armbruster
Marco Armbruster
SWStefan Wirth
Stefan Wirth
MSMax Seidensticker
Max Seidensticker