IH Rizuana

Dr. IH Rizuana

University Kebangsaan Malaysia Medical Centre, Kuala Lumpur, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2021 in Healthcare
Verified
Journal Article
Open access
PDF file
KTKar Choon Teoh
Kar Choon Teoh
HMHanani Abdul Manan
Hanani Abdul Manan
NNNorhashimah Mohd Norsuddin
Norhashimah Mohd Norsuddin
IRIH Rizuana
IH Rizuana
Early detection of breast cancer is diagnosed using mammography, the gold standard in breast screening. However, its increased use also provokes radiation-induced breast malignancy. Thus, monitoring and regulating the mean glandular dose (MGD) is essential. The purpose of this study was to determine MGD for full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) in the radiology department of a single centre. We also analysed the exposure factors as a function of breast thickness. A total of 436 patients underwent both FFDM and DBT. MGD was auto calculated by the mammographic machine for each projection. Patients’ data included compressed breast thickness (CBT), peak kilovoltage (kVp), milliampere-seconds (mAs) and MGD (mGy). Result analysis showed that there is a significant difference in MGD between the two systems, namely FFDM and DBT. However, the MGD values in our centre were comparable to other centres, as well as the European guideline (<2.5 mGy) for a standard breast. Although DBT improves the clinical outcome and quality of diagnosis, the risk of radiation-induced carcinogenesis should not be neglected. Regular quality control testing on mammography equipment must be performed for dose monitoring in women following a screening mammography in the future.

1 March 2014
Verified
Conference Paper
Closed access
AQAshwaq Qasem
Ashwaq Qasem
SASiti Norul Huda Sheikh Abdullah
Siti Norul Huda Sheikh Abdullah
SSShahnorbanun Sahran
Shahnorbanun Sahran
TWTengku Siti Meriam Tengku Wook
Tengku Siti Meriam Tengku Wook
IRIH Rizuana
IH Rizuana
FIFuad Ismail
Fuad Ismail
According to Breast Cancer Institute (BCI), Breast cancer is one of the most dangerous types of cancer that affects women all around the world. Based on clinical guidelines, the use of mammogram for an early detection of this cancer is an important step in reducing its danger. Thus, computer aided detection using image processing techniques in analyzing mammogram images and localizing abnormalities such as mass has been used. A False Positive (FP) rate is considered a challenge in localizing mass in mammogram images. Hence, in this paper, the rejection model based on the Support Vector Machine (SVM) has been used in reducing the FP rate of segmented mammogram images using the Chan-Vese method, initialized by the Marker Controller Watershed (MCWS) algorithm. Firstly, a mammogram image is segmented using the MCWS algorithm. Then, the segmentation is refined using Chan-Vese. After that, the SVM rejection model is built and is used in rejecting the non-correct segmented nodules. The dataset which consists of 16 nodules and 28 non-nodules has been obtained from the UKM Medical Centre. The experiment has shown the effectiveness of the SVM rejection model in reducing the FP rate compared to the result without the use of the SVM rejection model.

21 November 2018
Verified
Book Chapter
Open access
PDF file
SSShahnorbanun Sahran
Shahnorbanun Sahran
AQAshwaq Qasem
Ashwaq Qasem
KOKhairuddin Omar
Khairuddin Omar
DADheeb Abdelkarim Albashish
Dheeb Abdelkarim Albashish
DADR. AFZAN ADAM
DR. AFZAN ADAM
NSNordashima Abd Shukor
Nordashima Abd Shukor
This chapter discusses radio-pathological correlation with recent imaging advances such as machine learning (ML) with the use of technical methods such as mammography and histopathology. Although criteria for diagnostic categories for radiology and pathology are well established, manual detection and grading, respectively, are tedious and subjective processes and thus suffer from inter-observer and intra-observer variations. Two most popular techniques that use ML, computer aided detection (CADe) and computer aided diagnosis (CADx), are presented. CADe is a rejection model based on SVM algorithm which is used to reduce the False Positive (FP) of the output of the Chan-Vese segmentation algorithm that was initialized by the marker controller watershed (MCWS) algorithm. CADx method applies the ensemble framework, consisting of four-base SVM (RBF) classifiers, where each base classifier is a specialist and is trained to use the selected features of a particular tissue component. In general, both proposed methods offer alternative decision-making ability and are able to assist the medical expert in giving second opinion on more precise nodule detection. Hence, it reduces FP rate that causes over segmentation and improves the performance for detection and diagnosis of the breast cancer and is able to create a platform that integrates diagnostic reporting system.

1 March 2016
Verified
Conference Paper
Closed access
AKAli Kahwaji
Ali Kahwaji
HAHaslina Arshad
Haslina Arshad
SSShahnorbanun Sahran
Shahnorbanun Sahran
AGAli Garba Garba
Ali Garba Garba
IRIH Rizuana
IH Rizuana
As an emerging technology, UltraWide Band (UWB) wireless communications provides a very different approach to the antenna technology compared to narrow band systems, which has been a very attractive choice for medical antenna development. In this paper presents the design and simulation of a hexagonal microstrip antenna along with a breast phantom simulation. The antenna is simulated by introducing a hexagon slot in the center of the patch an impedance bandwidth nearly 5 GHz is achieved. The presented antenna has been designed and simulated successfully. The simulation analysis of designed antenna is carried out using HFSS software. The obtained results with this antenna make it a suitable antenna for UWB systems and portable applications.

1 June 2015 in Hong Kong Physiotherapy Journal
Verified
Journal Article
Closed access
LJLeonard H. Joseph
Leonard H. Joseph
IRIH Rizuana
IH Rizuana
ANAmaramalar S. Naicker
Amaramalar S. Naicker
OHOhnmar Htwe
Ohnmar Htwe
UPUbon Pirunsan
Ubon Pirunsan
APAatit Paungmali
Aatit Paungmali
BackgroundAltered motor patterns of the local muscle system (LS) and global muscle system (GS) is reported among low back pain patients. However, the pattern of changes in the LS and GS among individuals with sacroiliac joint dysfunction (SJD) is not clear.ObjectiveThis study aimed to investigate the changes in the resting muscle thickness of LS and GS in SJD.MethodsA total of 40 individuals (20 participants with SJD and 20 healthy participants as matched controls) participated in this study. The resting thickness of the LS and GS such as rectus abdominis (RA), external oblique (EO), internal oblique (IO), transverses abdominis (TrA), and lumbar multifidus (LM) was measured using real time ultrasonography and the data were compared between the ipsilateral side and contralateral side among participants with SJD as well as healthy participants. Parametric and nonparametric statistics were used to analyse the data as appropriate.ResultsThe results showed that EO and IO were significantly reduced among SJD participants when compared with the contralateral side. Similarly, EO and LM were significantly reduced among the SJD group when compared with the controls.ConclusionThe findings of the study support a trend of reduced size in the resting thickness of the LS and GS in SJD

1 September 2014 in Polish Annals of Medicine
Verified
Journal Article
Closed access
LJLeonard H. Joseph
Leonard H. Joseph
IRIH Rizuana
IH Rizuana
ANAmaramalar Selvi Naicker
Amaramalar Selvi Naicker
OHOHNMAR RASHIDAH ISMAIL HTWE
OHNMAR RASHIDAH ISMAIL HTWE
UPUbon Pirunsan
Ubon Pirunsan
APAatit Paungmali
Aatit Paungmali