This paper chooses the apparent diffusion coefficient for OH−(hydroxyl ion) for concrete as an index to evaluate the corrosion degree of concrete subjected to sulfuric acid. Based on the reaction boundary layer theory, a sulfuric acid corrosion model for concrete was established and verified through experiments. The experiment design and data processing of sulfuric acid corrosion tests for concrete were carried out using uniform test design and nonparametric regression. Effects of water‐cement ratio and pH value are presented on the sulfuric acid corrosion mechanism for concrete. Test results show that when the pH value was 2.50, the sulfuric acid corrosion degree of concrete was the most serious. The boundary layer effect always existed in the sulfuric acid corrosion for concrete, and the corrosion process included rapid and stable corrosion stages. The apparent diffusion coefficient for OH−for concrete increased with the decrease of pH value and the increase of water‐cement ratio and cement proportion.
This study investigates the effects of deionized water, seawater, and solutions with various concentrations (5% and 10% by mass) of HCl and NaOH on the physical and mechanical properties of glass fiber reinforced polymers (GFRPs) through aging tests at 20 °C, 50 °C, and 80 °C. The tensile properties of GFRP were assessed by tensile testing at room temperature, and the strain during the tensile process was observed using digital image correlation. Additionally, the degradation mechanism was analyzed using scanning electron microscopy, and long-term tensile properties were predicted based on the Arrhenius model. The results indicated that the tensile strength of the GFRP decreased by 22%, 71%, and 87% after 56 d of exposure to 5% NaOH solutions at 20 °C, 50 °C, and 80 °C, respectively. The alkaline solutions had a more severe effect on the GFRP than deionized water, seawater, and acidic solutions. The experimental values and Arrhenius model predictions were found to be in good agreement with each other.