10 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
YVYuriy Varetsky
Yuriy Varetsky
MGMichal Gajdzica
Michal Gajdzica
Current-limiting reactors are widely used in industrial electrical grids to reduce the current amplitude in the equipment and stabilize the voltage on the busbar during short circuits. Their application is distinguished by high technical and economic efficiency. However, mechanical damage to the reactors has been observed within extensive industrial grids with many induction motors and internal synchronous generators. The article analyses a case study of the reactor damage in the true industrial grid during a short circuit. An analysis of the damaged reactor’s previous operation had shown that there was a weakening of the fastenings in the reactor design, caused by the repeated starting currents of the grid motors and generators. A study of grid transients during short circuits was carried out by Matlab/Simulink software. The simulation results showed that the reactor could be damaged by a critical peak current in an unfavourable combination of the grid configuration and the short circuit location. The results of the study prove that, for industrial networks containing powerful induction motors and internal synchronous generators, the standardized procedure for selecting current-limiting reactors should additionally consider such factors as the localization in the grid, the effect of equipment-starting currents and possible grid configurations.

23 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
YVYuriy Varetsky
Yuriy Varetsky
MGMichal Gajdzica
Michal Gajdzica
Starting an induction motor causes voltage sag in the industrial grid that may disturb the operation of grid equipment. Direct-on-line starting is the simplest and most cost-effective method for starting induction motors, but also the most problematic. Large industries often use internal power plants with synchronous generators and starting powerful motors may impact the generator operations. The synchronous generators could be operated with the automatic or manual mode of voltage control. As the operation experience proves, the generator voltage control mode has a significant impact on the transient behaviours in the industrial power grid when starting a large induction motor. This article presents a case study of the synchronous generator tripping within a true medium-voltage industrial grid during the direct-on-line starting of a large induction motor driving the feed water pump. An analysis of the generator protection logs after the tripping showed that the synchronous generator was controlled in manual mode and its protection relay settings were exceeded. The transients initiated by induction motor starts were studied for possible configurations and operating conditions of the grid using a model developed on the Matlab/Simulink Software platform. The simulations have shown that concern about starting large motors in industrial grids containing internal synchronous generators needs to be solved considering the grid configurations and the coordination of generator protection and control devices.