10 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
YVYuriy Varetsky
Yuriy Varetsky
MGMichal Gajdzica
Michal Gajdzica
Current-limiting reactors are widely used in industrial electrical grids to reduce the current amplitude in the equipment and stabilize the voltage on the busbar during short circuits. Their application is distinguished by high technical and economic efficiency. However, mechanical damage to the reactors has been observed within extensive industrial grids with many induction motors and internal synchronous generators. The article analyses a case study of the reactor damage in the true industrial grid during a short circuit. An analysis of the damaged reactor’s previous operation had shown that there was a weakening of the fastenings in the reactor design, caused by the repeated starting currents of the grid motors and generators. A study of grid transients during short circuits was carried out by Matlab/Simulink software. The simulation results showed that the reactor could be damaged by a critical peak current in an unfavourable combination of the grid configuration and the short circuit location. The results of the study prove that, for industrial networks containing powerful induction motors and internal synchronous generators, the standardized procedure for selecting current-limiting reactors should additionally consider such factors as the localization in the grid, the effect of equipment-starting currents and possible grid configurations.

1 October 2011
Verified
Conference Paper
Closed access
ZHZbigniew Hanzelka
Zbigniew Hanzelka
YVYuriy Varetsky
Yuriy Varetsky
This paper discuses the properties of negative-sequence active power stream relative to the point of measurement in the unbalanced three-phase electric circuit. Analysis of the negative-sequence active power stream for the typical circuit asymmetry cases is carried out. It was shown that the stream direction can be used as an unbalance source index.

1 May 2020
Verified
Conference Paper
Closed access
YVYuriy Varetsky
Yuriy Varetsky
VKVolodymyr Konoval
Volodymyr Konoval
MSMykhajlo Seheda
Mykhajlo Seheda
This paper presents the issue of modeling dynamic power flow within a microgrid that is connected to a distribution grid. The microgrid contains wind generator and solar panels, an energy storage and a local load. The installation of such a system in a specific location requires the study of its components configuration and management. The aim of the study is elaboration of a tool for calculating optimal capacity an energy storage device within the selected ratings of the wind turbine and photovoltaic panels of the microgrid. Modeling power flow in the microgrid is proceeded taking into account seasonal wind and solar activities, temperature and using the corresponding load active power profile.

23 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
YVYuriy Varetsky
Yuriy Varetsky
MGMichal Gajdzica
Michal Gajdzica
Starting an induction motor causes voltage sag in the industrial grid that may disturb the operation of grid equipment. Direct-on-line starting is the simplest and most cost-effective method for starting induction motors, but also the most problematic. Large industries often use internal power plants with synchronous generators and starting powerful motors may impact the generator operations. The synchronous generators could be operated with the automatic or manual mode of voltage control. As the operation experience proves, the generator voltage control mode has a significant impact on the transient behaviours in the industrial power grid when starting a large induction motor. This article presents a case study of the synchronous generator tripping within a true medium-voltage industrial grid during the direct-on-line starting of a large induction motor driving the feed water pump. An analysis of the generator protection logs after the tripping showed that the synchronous generator was controlled in manual mode and its protection relay settings were exceeded. The transients initiated by induction motor starts were studied for possible configurations and operating conditions of the grid using a model developed on the Matlab/Simulink Software platform. The simulations have shown that concern about starting large motors in industrial grids containing internal synchronous generators needs to be solved considering the grid configurations and the coordination of generator protection and control devices.

1 April 2019
Verified
Conference Paper
Closed access
YVYuriy Varetsky
Yuriy Varetsky
VKVolodymyr Konoval
Volodymyr Konoval
MSMykhajlo Seheda
Mykhajlo Seheda
OPOlena Pastuh
Olena Pastuh
This paper discusses the issue of modeling a hybrid renewable energy system for a selected microgrid which is connected to the public distribution system. The subject of the study is a hybrid of solar panels, wind turbine and generalized energy storage. Presented model uses statistical indices of solar irradiation and wind speed data to simulate power flow in the system. The voltage variations character has been analyzed considering possible modes of wind generator reactive power control. Optimal reactive power control requirements are shown in consideration of voltage variation mitigation. The objective of the work is to create a tool for feasibility assessment of the energy hybrid system component operation and appropriate control strategy to provide its efficiency.

10 March 2016 in Tekhnichna Elektrodynamika
Verified
Journal Article
Closed access
YVYuriy Varetsky
Yuriy Varetsky
ZHZ. Hanzelka
Z. Hanzelka