Giovanna Dipasquale

Mrs. Giovanna Dipasquale

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2008 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
DWDamien Charles Weber
Damien Charles Weber
TZThomas Zilli
Thomas Zilli
FBFranz Buchegger
Franz Buchegger
NCNathalie Casanova
Nathalie Casanova
GHGuy Haller
Guy Haller
RMRaymond Miralbell
Raymond Miralbell
To compare morphological gross tumor volumes (GTVs), defined as pre- and postoperative gadolinium enhancement on T1-weighted magnetic resonance imaging to biological tumor volumes (BTVs), defined by the uptake of 18F fluoroethyltyrosine (FET) for the radiotherapy planning of high-grade glioma, using a dedicated positron emission tomography (PET)-CT scanner equipped with three triangulation lasers for patient positioning. Nineteen patients with malignant glioma were included into a prospective protocol using FET PET-CT for radiotherapy planning. To be eligible, patients had to present with residual disease after surgery. Planning was performed using the clinical target volume (CTV = GTV ∪ BTV) and planning target volume (PTV = CTV + 20 mm). First, the interrater reliability for BTV delineation was assessed among three observers. Second, the BTV and GTV were quantified and compared. Finally, the geometrical relationships between GTV and BTV were assessed. Interrater agreement for BTV delineation was excellent (intraclass correlation coefficient 0.9). Although, BTVs and GTVs were not significantly different (p = 0.9), CTVs (mean 57.8 ± 30.4 cm3) were significantly larger than BTVs (mean 42.1 ± 24.4 cm3; p < 0.01) or GTVs (mean 38.7 ± 25.7 cm3; p < 0.01). In 13 (68%) and 6 (32%) of 19 patients, FET uptake extended ≥ 10 and 20 mm from the margin of the gadolinium enhancement. Using FET, the interrater reliability had excellent agreement for BTV delineation. With FET PET-CT planning, the size and geometrical location of GTVs and BTVs differed in a majority of patients.

1 April 2011 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
AFAntonella Fogliata
Antonella Fogliata
SBStefan Bergström
Stefan Bergström
ICInes Cafaro
Ines Cafaro
ACAlessandro Clivio
Alessandro Clivio
LCLuca Cozzi
Luca Cozzi
DWDamien C. Weber
Damien C. Weber

1 December 2009 in International Journal of Radiation Oncology, Biology, Physics
Verified
Journal Article
Closed access
DWDamien C. Weber
Damien C. Weber
NPNicolas Peguret
Nicolas Peguret
GDGiovanna Dipasquale
Giovanna Dipasquale
LCLuca Cozzi
Luca Cozzi

1 December 2009 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
DWDamien C. Weber
Damien C. Weber
NCNathalie Casanova
Nathalie Casanova
TZThomas Zilli
Thomas Zilli
FBFranz Buchegger
Franz Buchegger
MRMichel Rouzaud
Michel Rouzaud
RMRaymond Miralbell
Raymond Miralbell

19 October 2018 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
GDGiovanna Dipasquale
Giovanna Dipasquale
APAlexis Poirier
Alexis Poirier
YSYannick Sprunger
Yannick Sprunger
JUJohannes Wilhelmus Edmond Uiterwijk
Johannes Wilhelmus Edmond Uiterwijk
RMRaymond Miralbell
Raymond Miralbell
Computed tomography (CT) data used for patient radiotherapy planning can nowadays be used to create 3D-printed boluses. Nevertheless, this methodology requires a second CT scan and planning process when immobilization masks are used in order to fit the bolus under it for treatment. This study investigates the use of a high-grade surface-scanner to produce, prior to the planning CT scan, a 3D-printed bolus in order to increase the workflow efficiency, improve treatment quality and avoid extra radiation dose to the patient. The scanner capabilities were tested on a phantom and on volunteers. A phantom was used to produce boluses in the orbital region either from CT data (resolution ≈1 mm), or from surface-scanner images (resolution 0.05 mm). Several 3D-printing techniques and materials were tested. To quantify which boluses fit best, they were placed on the phantom and scanned by CT. Hounsfield Unit (HU) profiles were traced perpendicular to the phantom’s surface. The minimum HU in the profiles was compared to the HU values for calibrated air-gaps. Boluses were then created from surface images of volunteers to verify the feasibility of surface-scanner use in-vivo. Phantom based tests showed a better fit of boluses modeled from surface-scanner than from CT data. Maximum bolus-to-skin air gaps were 1-2 mm using CT models and always < 0.6 mm using surface-scanner models. Tests on volunteers showed good and comfortable fit of boluses produced from surface-scanner images acquired in 0.6 to 7 min. Even in complex surface regions of the body such as ears and fingers, the high-resolution surface-scanner was able to acquire good models. A breast bolus model generated from images acquired in deep inspiration breath hold was also successful. None of the 3D-printed bolus using surface-scanner models required enlarging or shrinking of the initial model acquired in-vivo. Regardless of the material or printing technique, 3D-printed boluses created from high-resolution surface-scanner images proved to be superior in fitting compared to boluses created from CT data. Tests on volunteers were promising, indicating the possibility to improve overall radiotherapy treatments, primarily for megavoltage X-rays, using bolus modeled from a high-resolution surface-scanner even in regions of complex surface anatomy.

9 September 2009 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
DWDamien Charles Weber
Damien Charles Weber
HWHui Wang
Hui Wang
LCLuca Cozzi
Luca Cozzi
GDGiovanna Dipasquale
Giovanna Dipasquale
HKHaleem G Khan
Haleem G Khan
RMRaymond Miralbell
Raymond Miralbell
A study was performed comparing volumetric modulated arcs (RA) and intensity modulation (with photons, IMRT, or protons, IMPT) radiation therapy (RT) for patients with recurrent prostate cancer after RT. Plans for RA, IMRT and IMPT were optimized for 7 patients. Prescribed dose was 56 Gy in 14 fractions. The recurrent gross tumor volume (GTV) was defined on 18F-fluorocholine PET/CT scans. Plans aimed to cover at least 95% of the planning target volume with a dose > 50.4 Gy. A maximum dose (DMax) of 61.6 Gy was allowed to 5% of the GTV. For the urethra, DMax was constrained to 37 Gy. Rectal DMedian was < 17 Gy. Results were analyzed using Dose-Volume Histogram and conformity index (CI90) parameters. Tumor coverage (GTV and PTV) was improved with RA (V95% 92.6 ± 7.9 and 83.7 ± 3.3%), when compared to IMRT (V95% 88.6 ± 10.8 and 77.2 ± 2.2%). The corresponding values for IMPT were intermediate for the GTV (V95% 88.9 ± 10.5%) and better for the PTV (V95%85.6 ± 5.0%). The percentages of rectal and urethral volumes receiving intermediate doses (35 Gy) were significantly decreased with RA (5.1 ± 3.0 and 38.0 ± 25.3%) and IMPT (3.9 ± 2.7 and 25.1 ± 21.1%), when compared to IMRT (9.8 ± 5.3 and 60.7 ± 41.7%). CI90 was 1.3 ± 0.1 for photons and 1.6 ± 0.2 for protons. Integral Dose was 1.1 ± 0.5 Gy*cm3 *105 for IMPT and about a factor three higher for all photon's techniques. RA and IMPT showed improvements in conformal avoidance relative to fixed beam IMRT for 7 patients with recurrent prostate cancer. IMPT showed further sparing of organs at risk.