Antonella Fogliata

Antonella Fogliata

Auto-generated profile, based on publicly available information

Antonella Fogliata

Humanitas Research Hospital IRCCS Radiotherapy and Radiosurgery Dept Milan‐Rozzano Italy

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2008 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
LCLuca Cozzi
Luca Cozzi
KDKetayun Ardeshir Dinshaw
Ketayun Ardeshir Dinshaw
SSShyam Kishore Shrivastava
Shyam Kishore Shrivastava
UMUmesh Mahantshetty
Umesh Mahantshetty
REReena Engineer
Reena Engineer
AFAntonella Fogliata
Antonella Fogliata

24 October 2006 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
TKTommy Knöös
Tommy Knöös
EWElinore Wieslander
Elinore Wieslander
LCLuca Cozzi
Luca Cozzi
CBCarsten Brink
Carsten Brink
AFAntonella Fogliata
Antonella Fogliata
SLSøren Lassen
Søren Lassen
A study of the performance of five commercial radiotherapy treatment planning systems (TPSs) for common treatment sites regarding their ability to model heterogeneities and scattered photons has been performed. The comparison was based on CT information for prostate, head and neck, breast and lung cancer cases. The TPSs were installed locally at different institutions and commissioned for clinical use based on local procedures. For the evaluation, beam qualities as identical as possible were used: low energy (6 MV) and high energy (15 or 18 MV) x-rays. All relevant anatomical structures were outlined and simple treatment plans were set up. Images, structures and plans were exported, anonymized and distributed to the participating institutions using the DICOM protocol. The plans were then re-calculated locally and exported back for evaluation. The TPSs cover dose calculation techniques from correction-based equivalent path length algorithms to model-based algorithms. These were divided into two groups based on how changes in electron transport are accounted for ((a) not considered and (b) considered). Increasing the complexity from the relatively homogeneous pelvic region to the very inhomogeneous lung region resulted in less accurate dose distributions. Improvements in the calculated dose have been shown when models consider volume scatter and changes in electron transport, especially when the extension of the irradiated volume was limited and when low densities were present in or adjacent to the fields. A Monte Carlo calculated algorithm input data set and a benchmark set for a virtual linear accelerator have been produced which have facilitated the analysis and interpretation of the results. The more sophisticated models in the type b group exhibit changes in both absorbed dose and its distribution which are congruent with the simulations performed by Monte Carlo-based virtual accelerator.

1 July 2009 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
EVEugenio Vanetti
Eugenio Vanetti
ACAlessandro Clivio
Alessandro Clivio
GNGiorgia Nicolini
Giorgia Nicolini
AFAntonella Fogliata
Antonella Fogliata
SGSarbani Ghosh-Laskar
Sarbani Ghosh-Laskar
LCLuca Cozzi
Luca Cozzi

8 February 2007 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
AFAntonella Fogliata
Antonella Fogliata
EVEugenio Vanetti
Eugenio Vanetti
DADirk Albers
Dirk Albers
CBCarsten Brink
Carsten Brink
ACAlessandro Clivio
Alessandro Clivio
LCLuca Cozzi
Luca Cozzi
A comparative study was performed to reveal differences and relative figures of merit of seven different calculation algorithms for photon beams when applied to inhomogeneous media. The following algorithms were investigated: Varian Eclipse: the anisotropic analytical algorithm, and the pencil beam with modified Batho correction; Nucletron Helax-TMS: the collapsed cone and the pencil beam with equivalent path length correction; CMS XiO: the multigrid superposition and the fast Fourier transform convolution; Philips Pinnacle: the collapsed cone. Monte Carlo simulations (MC) performed with the EGSnrc codes BEAMnrc and DOSxyznrc from NRCC in Ottawa were used as a benchmark. The study was carried out in simple geometrical water phantoms (rho = 1.00 g cm(-3)) with inserts of different densities simulating light lung tissue (rho = 0.035 g cm(-3)), normal lung (rho = 0.20 g cm(-3)) and cortical bone tissue (rho = 1.80 g cm(-3)). Experiments were performed for low- and high-energy photon beams (6 and 15 MV) and for square (13 x 13 cm2) and elongated rectangular (2.8 x 13 cm2) fields. Analysis was carried out on the basis of depth dose curves and transverse profiles at several depths. Assuming the MC data as reference, gamma index analysis was carried out distinguishing between regions inside the non-water inserts or inside the uniform water. For this study, a distance to agreement was set to 3 mm while the dose difference varied from 2% to 10%. In general all algorithms based on pencil-beam convolutions showed a systematic deficiency in managing the presence of heterogeneous media. In contrast, complicated patterns were observed for the advanced algorithms with significant discrepancies observed between algorithms in the lighter materials (rho = 0.035 g cm(-3)), enhanced for the most energetic beam. For denser, and more clinical, densities a better agreement among the sophisticated algorithms with respect to MC was observed.

1 December 2014 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
AFAntonella Fogliata
Antonella Fogliata
FBFrancesca Belosi
Francesca Belosi
ACAlessandro Clivio
Alessandro Clivio
PNPiera Navarria
Piera Navarria
GNGiorgia Nicolini
Giorgia Nicolini
LCLuca Cozzi
Luca Cozzi

1 December 2008 in Radiotherapy and Oncology
Verified
Journal Article
Closed access
AFAntonella Fogliata
Antonella Fogliata
ACAlessandro Clivio
Alessandro Clivio
GNGiorgia Nicolini
Giorgia Nicolini
EVEugenio Vanetti
Eugenio Vanetti
LCLuca Cozzi
Luca Cozzi