We aimed to compare clinical and radiologic outcomes in patients with cam-type femoroacetabular impingement (FAI), with and without a partial ligamentum teres (LT) tear, who underwent hip arthroscopy (HA) with ≥10 years of follow-up. Among the patients who underwent HA for a cam-type FAI diagnosis with a labral tear, 28 patients (28 hips) with a partial LT tear and 87 patients (99 hips) with an intact LT were assigned to Groups A and B, respectively. All patients underwent partial labral debridement and femoroplasty. Debridement and thermal shrinkage were performed for LT tears. The grade of chondral damage was measured intraoperatively. Clinical items were assessed preoperatively and at the last follow-up. Patients’ satisfaction with the surgery and changes in postoperative sports ability in those who had previously been active in sports were assessed at the last follow-up. The Tönnis grade was assessed preoperatively and at the last follow-up for radiologic evaluation. Chondral damage to the acetabular and femoral head detected intraoperatively was significantly different between the groups (P = 0.005 and P < 0.001). At the last follow-up, Group A patients experienced more difficulty performing sports activities than Group B patients (P = 0.056), and significantly, more Group A patients had stopped exercising despite their active participation in sports preoperatively (P = 0.002). Regarding the Tönnis grade, significant differences were found only at the final follow-up (P = 0.020). Patients with partial LT tear showed a higher grade of chondral damage, experienced decreased exercise capacity and had significantly worsened Tönnis grades, suggesting hip osteoarthritis progression compared to those with an intact LT.
The applicability of a polyether ether ketone locking compression plate (PEEK LCP) fabricated using FDM (fused deposition modeling)-based 3D printing to treat actual patients was studied. Three different tests—bending, axial compression, and axial torsion—were conducted on tibial non-osteoporotic comminuted diaphyseal fracture samples fixed with the commercial titanium alloy LCP and 3D-printed PEEK LCP. Comparing the outcomes of these tests revealed that the commercial titanium alloy LCP underwent plastic deformation in the bending and axial torsion tests, though the LCP did not fail even when an external force greater than the maximum allowable load of the tibia fixture of the LCP was applied. Elastic deformation occurred in the 3D-printed PEEK LCP in the bending and axial torsion tests. However, deformation occurred even under a small external force, and its stiffness was 10% compared to commercial titanium alloy LCP. Thus, 3D-printed PEEK LCP can be applied to the fracture conditions in non-weight-bearing regions. The experimental results reveal detailed insights into the treatment of actual patients by considering the stiffness and high toughness of 3D-printed PEEK LCP.
Background and Objectives: Patients experience severe pain after surgical correction of ankle fractures. Although their exact mechanism is unknown, dexamethasone and epinephrine increase the analgesic effect of anesthetics in peripheral nerve blocks. This study aimed to compare the postoperative pain control efficacy of peripheral nerve blocks with ropivacaine combined with dexamethasone/epinephrine and peripheral nerve blocks with only ropivacaine and added patient-controlled analgesia in patients with ankle fractures. Materials and Methods: This randomized, controlled prospective study included patients aged 18–70 years surgically treated for ankle fractures between December 2021 and September 2022. The patients were divided into group A (n = 30), wherein pain was controlled using patient-controlled analgesia after lower extremity peripheral nerve block, and group B (n = 30), wherein dexamethasone/epinephrine was combined with the anesthetic solution during peripheral nerve block. In both groups, ropivacaine was used as the anesthetic solution for peripheral nerve block, and this peripheral nerve block was performed just before ankle surgery for the purpose of anesthesia for surgery. Pain (visual analog scale), patient satisfaction, and side effects were assessed and compared between the two groups. Results: The patients’ demographic data were similar between groups. Pain scores were significantly lower in group B than in group A postoperatively. Satisfaction scores were significantly higher in group B (p = 0.003). There were no anesthesia-related complications in either group. Conclusions: Dexamethasone and epinephrine as adjuvant anesthetic solutions can effectively control pain when performing surgery using peripheral nerve blocks for patients with ankle fractures.
Case Report: An 83-year-old woman presented with a high-energy tibial fracture. We treated her with temporary external fixation and delayed flexible intramedullary nailing because of extensive soft-tissue damage and interference from the hardware retained from a previous total knee arthroplasty. Conclusions: In our opinion, flexible intramedullary nailing is an effective procedure and provides good functional and radiological results in high-energy tibial fractures with extensive soft-tissue loss.
1 January 2021 in Journal of the Korean Orthopaedic Association