Hyung Jin Chung

Dr. Hyung Jin Chung


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Korean Journal of Anesthesiology
Verified
Journal Article
Open access
PDF file
YJYumin Jo
Yumin Jo
COChahyun Oh
Chahyun Oh
WLWoo-Yong Lee
Woo-Yong Lee
HCHyung Jin Chung
Hyung Jin Chung
HPHanmi Park
Hanmi Park
BHBoohwi Hong
Boohwi Hong
Background: Among the various diaphragm-sparing alternatives to interscalene block, costoclavicular block (CCB) demonstrated a low hemidiaphragmatic paresis (HDP) occurrence but an inconsistent analgesic effect in arthroscopic shoulder surgery. We hypothesized that a larger volume of local anesthetic for CCB could provide sufficient analgesia by achieving sufficient supraclavicular spreading.Methods: Sixty patients scheduled for arthroscopic rotator cuff repair were randomly assigned to receive CCB using one of two volumes of local anesthetic (CCB20, 0.75% ropivacaine 20 ml; CCB40, 0.375% ropivacaine 40 ml). The primary outcome was the rate of complete analgesia (0 on the numeric rating scale of pain) at 1 h postoperatively. The secondary outcomes included a sonographic assessment of local anesthetic spread, diaphragmatic function, pulmonary function, postoperative opioid use, and other pain-related experiences within 24 h postoperatively. Results: The rates of complete analgesia were not significantly different (23.3% [7/30] and 33.3% [10/30] in the CCB20 and CCB40 groups, respectively; risk difference 10%, 95% CI [–13, 32], P = 0.567). There were no significant differences in other pain-related outcomes. Among the clinical factors considered, the only factor significantly associated with postoperative pain was the sonographic observation of supraclavicular spreading. There were no significant differences in the incidence of HDP and the change in pulmonary function between the two groups.Conclusions: Using 40 ml of local anesthetic does not guarantee supraclavicular spread during CCB. Moreover, it does not result in a higher rate of complete analgesia compared to using 20 ml of local anesthetic in arthroscopic shoulder surgery.

1 January 2024 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
WLWoo-Yong Lee
Woo-Yong Lee
YJYoo-Sun Jeon
Yoo-Sun Jeon
KKKyung-Cheon Kim
Kyung-Cheon Kim
HSHyun-Dae Shin
Hyun-Dae Shin
YJYong Bum Joo
Yong Bum Joo
HCHyung Jin Chung
Hyung Jin Chung
Lee WY, et al. Clin Orthop Surg. 2024 Oct;16(5):751-760. https://doi.org/10.4055/cios24015

1 January 2024 in Clinics in Orthopedic Surgery
Verified
Journal Article
Open access
PDF file
JLJeong-Kil Lee
Jeong-Kil Lee
MJMeesun Jung
Meesun Jung
HLHan Byul Lee
Han Byul Lee
HCHyung Jin Chung
Hyung Jin Chung
SLSeung Hoo Lee
Seung Hoo Lee
Lee JK, et al. Clin Orthop Surg. 2024 Jun;16:e38. https://doi.org/10.4055/cios23383

19 July 2023 in BMC Musculoskeletal Disorders
Verified
Journal Article
Open access
PDF file
YJYong Bum Joo
Yong Bum Joo
WLWoo Yong Lee
Woo Yong Lee
HCHyung Jin Chung
Hyung Jin Chung
Background: Suprascapular nerve entrapment is a rare disorder that is frequently misdiagnosed as another disease. The suprascapular nerve is commonly entrapped at the following two sites: the suprascapular and spinoglenoid notches. Nerve entrapment at the spinoglenoid notch causes infraspinatus muscle weakness and atrophy. Patients present with posterior shoulder pain and weakness. Magnetic resonance imaging is used to confirm the diagnosis of a spinoglenoid cyst and nerve compression. Open or arthroscopic aspiration or decompression is indicated for patients with cysts in whom conservative treatment has failed and those with cysts associated with suprascapular nerve compression. Case presentation: Herein, we describe the case of a 49-year-old man with suprascapular nerve entrapment caused by a large cyst, namely, a hematoma, in the superior scapular and spinoglenoid notches. Open surgical decompression of the suprascapular nerve was performed owing to an intact rotator cuff and glenoid labrum. Conclusion: Posterior shoulder pain promptly resolved without complications.

16 July 2023 in Polymers
Verified
Journal Article
Open access
PDF file
HCHyung Jin Chung
Hyung Jin Chung
HLHo-Beom Lee
Ho-Beom Lee
KPKwang-Min Park
Kwang-Min Park
TJTae-Gon Jung
Tae-Gon Jung
SKSang-Bum Kim
Sang-Bum Kim
JLJeong-Kil Lee
Jeong-Kil Lee
The applicability of a polyether ether ketone locking compression plate (PEEK LCP) fabricated using FDM (fused deposition modeling)-based 3D printing to treat actual patients was studied. Three different tests—bending, axial compression, and axial torsion—were conducted on tibial non-osteoporotic comminuted diaphyseal fracture samples fixed with the commercial titanium alloy LCP and 3D-printed PEEK LCP. Comparing the outcomes of these tests revealed that the commercial titanium alloy LCP underwent plastic deformation in the bending and axial torsion tests, though the LCP did not fail even when an external force greater than the maximum allowable load of the tibia fixture of the LCP was applied. Elastic deformation occurred in the 3D-printed PEEK LCP in the bending and axial torsion tests. However, deformation occurred even under a small external force, and its stiffness was 10% compared to commercial titanium alloy LCP. Thus, 3D-printed PEEK LCP can be applied to the fracture conditions in non-weight-bearing regions. The experimental results reveal detailed insights into the treatment of actual patients by considering the stiffness and high toughness of 3D-printed PEEK LCP.

9 April 2023 in Medicina
Verified
Journal Article
Open access
PDF file
YJYong Bum Joo
Yong Bum Joo
YJYoo Sun Jeon
Yoo Sun Jeon
WLWoo Yong Lee
Woo Yong Lee
HCHyung Jin Chung
Hyung Jin Chung
Background and objectives: Iatrogenic fractures are potential complications during intramedullary (IM) nailing for atypical femoral fractures (AFFs). The risk factors associated with iatrogenic fractures remain unclear, although excessive femoral bowing and osteoporosis are hypothesized to be contributing factors. The present study aimed to determine the risk factors for the occurrence of iatrogenic fractures during IM nailing in patients with AFFs. Materials and Methods: This retrospective cross-sectional study evaluated 95 patients with AFF (all female; age range: 49–87 years) who underwent IM nailing between June 2008 and December 2017. The patients were divided into two groups: Group I (with iatrogenic fracture: n = 20) and Group II (without iatrogenic fracture: n = 75). Background characteristics were retrieved from medical records and radiographic measurements were obtained. Univariate and multivariate logistic regression analyses were performed to identify risk factors for the occurrence of intraoperative iatrogenic fractures. Receiver operating curve (ROC) analysis was conducted to determine a cut-off value for the prediction of iatrogenic fracture occurrence. Results: Iatrogenic fractures occurred in 20 (21.1%) patients. The two groups exhibited no significant differences regarding age and other background characteristics. Group I exhibited significantly lower mean femoral bone mineral density (BMD) and significantly greater mean lateral and anterior femoral bowing angles than Group II (all p < 0.05). There were no significant differences in AFF location, nonunion, and IM nail diameter, length, or nail entry point between the two groups. In the univariate analysis, femoral BMD and lateral bowing of the femur differed significantly between the two groups. On multivariate analysis, only lateral bowing of the femur remained significantly associated with iatrogenic fracture occurrence. The ROC analysis determined a cut-off value of 9.3° in lateral bowing of the femur for prediction of iatrogenic fracture occurrence during IM nailing for AFF treatment. Conclusions: The lateral bowing angle of the femur is an important predictive factor for intraoperative iatrogenic fracture occurrence in patients undergoing IM nailing for AFF treatment.