Gold (Au)-decorated iron oxide (Fe3O4), Au/Fe3O4, Janus nanoparticles were fabricated via the continuous route for aerosol Au incorporation with Fe3O4 domains synthesized in an aqueous medium as multifunctional nanoplatforms. The fabricated nanoparticles were subsequently exposed to 185-nm UV light to generate positive charges on Au surfaces, and their activities were tested in computed tomography (CT) and magnetic resonance (MR) imaging, gene-delivery and photothermal therapy. No additional polymeric coatings of the Janus particles also had a unique ability to suppress inflammatory responses in macrophages challenged with lipopolysaccharide, which may be due to the absence of amine groups.
14 March 2019 in Journal of Occupational and Environmental Hygiene
There is great concern regarding the adverse health implications of engineered nanoparticles. However, there are many circumstances where the production of incidental nanoparticles, i.e., nanoparticles unintentionally generated as a side product of some anthropogenic process, is of even greater concern. In this study, metal-based incidental nanoparticles were measured in two occupational settings: a machining center and a foundry. On-site characterization of substrate-deposited incidental nanoparticles using a field-portable X-ray fluorescence provided some insights into the chemical characteristics of these metal-containing particles. The same substrates were then used to carry out further off-site analysis including single-particle analysis using scanning electron microscopy and energy-dispersive X-ray spectroscopy. Between the two sites, there were similarities in the size and composition of the incidental nanoparticles as well as in the agglomeration and coagulation behavior of nanoparticles. In particular, incidental nanoparticles were identified in two forms: submicrometer fractal-like agglomerates from activities such as welding and supermicrometer particles with incidental nanoparticles coagulated to their surface, herein referenced as nanoparticle collectors. These agglomerates will affect deposition and transport inside the respiratory system of the respirable incidental nanoparticles and the corresponding health implications. The studies of incidental nanoparticles generated in occupational settings lay the groundwork on which occupational health and safety protocols should be built.
In this study, a size-selective bioaerosol sampler was built and combined with adenosine triphosphate (ATP) bioluminescence assay for measuring the bioaerosol concentration more rapidly and easily. The ATP bioaerosol sampler consisted of a respirable cyclone, an impactor to collect bioaerosols onto the head of a swab used for ATP bioluminescence assay, a swab holder, and a sampling pump. The collection efficiency of the impactor was tested using aerosolized sodium chloride particles and then the particle diameter corresponding to the collection efficiency of 50% (cut-off diameter) was evaluated. The experimental cut-off diameter was 0.44 μm. The correlations between ATP bioluminescence (relative light unit; RLU) from commercially available swabs (UltraSnap and SuperSnap, Hygiena, LLC, U.S.A.) and colony forming unit (CFU) were examined using Escherichia coli (E. coli) suspension and then the conversion equations from RLU to CFU were obtained. From the correlation results, the R2 values of UltraSnap and SuperSnap were 0.53 and 0.81, respectively. The conversion equations were the linear function and the slopes of UltraSnap and SuperSnap were 633.6 and 277.78, respectively. In the lab and field tests, the ATP bioaerosol sampler and a conventional Andersen impactor were tested and the results were compared. In the lab tests, concentrations of aerosolized E. coli collected using the sampler were highly correlated to those from the Anderson impactor (R2 = 0.85). In the field tests, the concentrations measured using the ATP bioaerosol sampler were higher than those from the Andersen impactor due to the limitations of the colony counting method. These findings confirm the feasibility of developing a sampler for rapid measurement of bioaerosol concentrations, offering a compact device for measuring exposure to bioaerosols, and an easy-to-use methodological concept for efficient air quality management.
14 January 2021 in Laryngoscope Investigative Otolaryngology
Objective: Cadaveric simulations have shown endonasal drilling and cautery generate aerosols, which is a significant concern for otolaryngologists during the COVID‐19 era. This study quantifies aerosol generation during routine rhinologic surgeries and in‐office procedures in live patients.Methods: Aerosols ranging from 0.30 to 10.0 μm were measured in real‐time using an optical particle sizer during surgeries and in‐office procedures. Various mask conditions were tested during rigid nasal endoscopy (RNE) and postoperative debridement (POD).Results: Higher aerosol concentrations (AC) ranging from 2.69 to 10.0 μm were measured during RNE (n = 9) with no mask vs two mask conditions (P = .002 and P = .017). Mean AC (0.30‐10.0 μm) were significantly higher during POD (n = 9) for no mask vs a mask covering the patient's mouth condition (mean difference = 0.16 ± 0.03 particles/cm3, 95% CI 0.10‐0.22, P < .001). There were no discernible spikes in aerosol levels during endoscopic septoplasty (n = 3). Aerosol spikes were measured in two of three functional endoscopic sinus surgeries (FESS) with microdebrider. Using suction mitigation, there were no discernible spikes during powered drilling in two anterior skull base surgeries (ASBS).Conclusion: Use of a surgical mask over the patient's mouth during in‐office procedures or a mask with a slit for an endoscope during RNE significantly diminished aerosol generation. However, whether this reduction in aerosol generation is sufficient to prevent transmission of communicable diseases via aerosols was beyond the scope of this study. There were several spikes in aerosols during FESS and ASBS, though none were associated with endonasal drilling with the use of suction mitigation.Level of Evidence: 4.