Jose Israel Sanchez Cruz

Mr. Jose Israel Sanchez Cruz

IPN

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
Juan Carlos Paredes RojasJuan Carlos Paredes Rojas
Juan Carlos Paredes Rojas
JCJose Israel Sanchez Cruz
Jose Israel Sanchez Cruz
JLJose Alfredo Leal-Naranjo
Jose Alfredo Leal-Naranjo
AOARMANDO OROPEZA OSORNIO
ARMANDO OROPEZA OSORNIO
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
This work presents a design for an automatized multiposition dynamic wheelchair used to transport quadriplegic patients by reconfiguring a manual wheelchair structure. An electric actuator is attached to a four-bar mechanism fixed to each side of a wheelchair’s backrest to reach multiposition. The entire device is actuated through a PID controller. An experimental test is carried out in a simplified wheelchair structure. Finally, the structure of the wheelchair is evaluated through the Dynamic analysis and Finite Element Method under the payload computed with the most critical position reached by the mechanism.

11 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
JCJose Israel Sanchez Cruz
Jose Israel Sanchez Cruz
JFJuan-Alejandro Flores-Campos
Juan-Alejandro Flores-Campos
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Osteogenesis Imperfecta (IO) is a bone disease mainly characterized by the low bone density that produces common fractures in children around 0–7 years. The use of metal implants is a typical treatment of this disease. The intramedullary telescopic nail (ITN) was inspired by the progressive growth in the long bones such as the femur or humerus during children’s aging. This work shows an experimental assessment of the ITN’s, focusing on their fixation; the proposed improvements in the design of the intramedullary nail studied include the separation of the element into two parts for telescopic enlargement, minimal invasive fixation through the distal anchorage, and the double auto-drilled end for fixation on the distal and proximal section of the bone. The samples were manufactured in 316 L steel and mounted on specialized jaws to replicate the implants’ boundary conditions. The experimental test was repeated three times to report the intramedullary telescopic nail’s behavior at three lengths. The results show that the device supports only 79.06 N when not at extension length. However, if the device is extended 150% it will support 46.87 N which suggests that intramedullary telescopic nails can only increase by 25% of their original length before they fail.