Luis Antonio Aguilar

Dr. Luis Antonio Aguilar

Departamento de Sistemas Biomédicos, UNAM-Facultad de Ingeniería, Mexico City, Ciudad de México, Mexico
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2018 in Latin American Journal of Solids and Structures
Verified
Journal Article
Open access
PDF file
JLJosé-Alfredo Leal-Naranjo
José-Alfredo Leal-Naranjo
Marco CeccarelliMarco Ceccarelli
Marco Ceccarelli
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
GUGuillermo Urriolagoitia-Sosa
Guillermo Urriolagoitia-Sosa
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon
This paper presents a synthesis of a spherical parallel manipulator for a shoulder of a seven-degrees-of-freedom prosthetic human arm using a multi-objective optimization. Three design objectives are considered, namely the workspace, the dexterity, and the actuators torques. The parallel manipulator is modelled considering 13 design parameters in an optimization procedure. Due to the non-linearity of the design problem, genetic algorithms are implemented. The outcomes show that a suitable performance of the manipulator is achieved using the proposed optimization.

12 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
Juan Carlos Paredes RojasJuan Carlos Paredes Rojas
Juan Carlos Paredes Rojas
JCJose Israel Sanchez Cruz
Jose Israel Sanchez Cruz
JLJose Alfredo Leal-Naranjo
Jose Alfredo Leal-Naranjo
AOARMANDO OROPEZA OSORNIO
ARMANDO OROPEZA OSORNIO
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
This work presents a design for an automatized multiposition dynamic wheelchair used to transport quadriplegic patients by reconfiguring a manual wheelchair structure. An electric actuator is attached to a four-bar mechanism fixed to each side of a wheelchair’s backrest to reach multiposition. The entire device is actuated through a PID controller. An experimental test is carried out in a simplified wheelchair structure. Finally, the structure of the wheelchair is evaluated through the Dynamic analysis and Finite Element Method under the payload computed with the most critical position reached by the mechanism.

7 December 2023 in Results in Engineering
Verified
Journal Article
Open access
CGCarlos Alberto Espinoza Garcés
Carlos Alberto Espinoza Garcés
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
JRJosé Luis Rueda-Arreguin
José Luis Rueda-Arreguin
IPIsrael Pérez-Martínez
Israel Pérez-Martínez
JTJose Luis Torres-Ariza
Jose Luis Torres-Ariza
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel

14 December 2021 in Children
Verified
Journal Article
Open access
PDF file
VRViridiana Ramírez-Vela
Viridiana Ramírez-Vela
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
Juan Carlos Paredes RojasJuan Carlos Paredes Rojas
Juan Carlos Paredes Rojas
JFJuan-Alejandro Flores-Campos
Juan-Alejandro Flores-Campos
YOYolanda Donají Ortiz-Hernández
Yolanda Donají Ortiz-Hernández
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
This work presents a non-invasive methodology to obtain a three-dimensional femur model of three-year-old infants affected with Osteogenesis Imperfecta (OI) type III. DICOM® Files of a femur were processed to obtain a finite element model to assess the transverse, the oblique, and the comminuted fractures. The model is evaluated under a normal walking cycle. The loads applied were considered the most critical force generated on the normal walking cycle, and the analyses considered anisotropic bone conditions. The outcome shows stress concentration areas in the central zone of the diaphysis of the femur, and the highest levels of stress occur in the case of the comminuted fracture, while the transverse fracture presents the lowest values. Thus, the method can be helpful for determining the bone fracture behavior of certain pathologies, such as osteogenesis imperfecta, osteopenia, and osteoporosis.

30 September 2017 in Mechanisms and Machine Science
Verified
Book Chapter
Closed access
PDF file
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
MCM. Ceccarelli
M. Ceccarelli
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
GUG. Urriolagoitia-Sosa
G. Urriolagoitia-Sosa
GUGuillermo Manuel Urriolagoitia-Calderon
Guillermo Manuel Urriolagoitia-Calderon

1 January 2017 in DYNA Ingenieria e Industria
Verified
Journal Article
Closed access
OVOmar Cortes Vasquez
Omar Cortes Vasquez
CMChristopher René Torres San Miguel
Christopher René Torres San Miguel
GSGuillermo Urriolagoitia Sosa
Guillermo Urriolagoitia Sosa
ICIván Lenín Cruz-Jaramillo
Iván Lenín Cruz-Jaramillo
Luis Antonio AguilarLuis Antonio Aguilar
Luis Antonio Aguilar
GCGuillermo Manuel Urriolagoitia Calderón
Guillermo Manuel Urriolagoitia Calderón