Robert Plumb

Prof. Robert Plumb

Waters Corporation

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2004 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
RPRobert Plumb
Robert Plumb
JCJose Castro‐Perez
Jose Castro‐Perez
JGJennifer Granger
Jennifer Granger
IBIain Beattie
Iain Beattie
KJKarine Joncour
Karine Joncour
AWAndrew Wright
Andrew Wright

27 April 2005 in The Analyst
Verified
Journal Article
Closed access
PDF file
RPRobert Plumb
Robert Plumb
JGJennifer H. Granger
Jennifer H. Granger
CSChris L. Stumpf
Chris L. Stumpf
KJKelly A. Johnson
Kelly A. Johnson
BSBrian W. Smith
Brian W. Smith
JCJose Castro-Perez
Jose Castro-Perez
The use of Ultra Performance Liquid Chromatography (UPLC), with a rapid 1.5 minute reversed-phase gradient separation on a 1.7 µm reversed-phase packing material to provide rapid “high throughput” support for metabonomic screening is demonstrated. The peak capacity and the number of marker ions detected using these fast UPLC separations and oa-TOF MS was found to be similar to that generated by conventional HPLC-MS methods with a 10 minute separation. The UPLC-MS methodology was applied to the analysis of urine samples from rodents, including normal and Zucker obese rats and three strains of mice (of both sexes), and was found to provide rapid discrimination between age, strain, gender and diurnal variation.

25 September 2002 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
PDF file
RPRobert Plumb
Robert Plumb
CSChris L. Stumpf
Chris L. Stumpf
MGMarc V. Gorenstein
Marc V. Gorenstein
JCJose M. Castro‐Perez
Jose M. Castro‐Perez
GDGordon J. Dear
Gordon J. Dear
JHJohn N. Haselden
John N. Haselden

5 November 2003 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Open access
PDF file
RPRobert Plumb
Robert Plumb
CSChris L. Stumpf
Chris L. Stumpf
JGJennifer H. Granger
Jennifer H. Granger
JCJose Castro‐Perez
Jose Castro‐Perez
JHJohn N. Haselden
John N. Haselden
GDGordon J. Dear
Gordon J. Dear
The process of metabolite identification is essential to the drug discovery and development process; this is usually achieved by liquid chromatography/tandem mass spectrometry (LC/MS/MS) or a combination of liquid chromatography/mass spectrometry (LC/MS) and nuclear magnetic resonance (NMR) spectroscopy. Metabolite identification is, however, a time‐consuming process requiring an experienced skilled scientist. Multivariate statistical analysis has been used in the field of metabonomics to elucidate differences in endogenous biological profiling due to a toxic effect or a disease state. In this paper we show how a combination of liquid chromatography/time‐of‐flight mass spectrometry (LC/TOFMS) and multivariate statistical analysis can be used to detect drug metabolites in a biological fluid with no prior knowledge of the compound administered. Copyright © 2003 John Wiley & Sons, Ltd.

27 January 2023 in TrAC Trends in Analytical Chemistry
Verified
Journal Article
Open access
RPRobert Plumb
Robert Plumb
LGLee A. Gethings
Lee A. Gethings
PRPaul D. Rainville
Paul D. Rainville
GIGiorgis Isaac
Giorgis Isaac
RTRobert Trengove
Robert Trengove
Ian WilsonIan Wilson
Ian Wilson

15 February 2023 in Analytical Chemistry
Verified
Journal Article
Open access
Georgios TheodoridisGeorgios Theodoridis
Georgios Theodoridis
Helen GikaHelen Gika
Helen Gika
DRDaniel Raftery
Daniel Raftery
RGRoyston Goodacre
Royston Goodacre
RPRobert Plumb
Robert Plumb
Ian WilsonIan Wilson
Ian Wilson
Metabolite identification represents a major bottleneck in contemporary metabolomics research and a step where critical errors may occur and pass unnoticed. This is especially the case for studies employing liquid chromatography-mass spectrometry technology, where there is increased concern on the validity of the proposed identities. In the present perspective article, we describe the issue and categorize the errors into two types: identities that show poor biological plausibility and identities that do not comply with chromatographic data and thus to physicochemical properties (usually hydrophobicity/hydrophilicity) of the proposed molecule. We discuss the problem, present characteristic examples, and propose measures to improve the situation.