Michael Grunert

Dr. Michael Grunert

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2021 in Cancers
Verified
Journal Article
Open access
PDF file
PSPhilipp Seifert
Philipp Seifert
SSSimone Agnes Schenke
Simone Agnes Schenke
MZMichael Zimny
Michael Zimny
ASAlexander Stahl
Alexander Stahl
MGMichael Grunert
Michael Grunert
RGRainer Görges
Rainer Görges
Germany has a long history of insufficient iodine supply and thyroid nodules occur in over 30% of the adult population, the vast majority of which are benign. Non-invasive diagnostics remain challenging, and ultrasound-based risk stratification systems are essential for selecting lesions requiring further clarification. However, no recommendation can yet be made about which system performs the best for iodine deficiency areas. In a German multicenter approach, 1211 thyroid nodules from 849 consecutive patients with cytological or histopathological results were enrolled. Scintigraphically hyperfunctioning lesions were excluded. Ultrasound features were prospectively recorded, and the resulting classifications according to five risk stratification systems were retrospectively determined. Observations determined 1022 benign and 189 malignant lesions. The diagnostic accuracies were 0.79, 0.78, 0.70, 0.82, and 0.79 for Kwak Thyroid Imaging Reporting and Data System (Kwak-TIRADS), American College of Radiology (ACR) TI-RADS, European Thyroid Association (EU)-TIRADS, Korean-TIRADS, and American Thyroid Association (ATA) Guidelines, respectively. Receiver Operating Curves revealed Areas under the Curve of 0.803, 0.795, 0.800, 0.805, and 0.801, respectively. According to the ATA Guidelines, 135 thyroid nodules (11.1%) could not be classified. Kwak-TIRADS, ACR TI-RADS, and Korean-TIRADS outperformed EU-TIRADS and ATA Guidelines and therefore can be primarily recommended for non-autonomously functioning lesions in areas with a history of iodine deficiency.

19 July 2021 in Cancers
Verified
Journal Article
Open access
PDF file
APAmeya Puranik
Ameya Puranik
CDClarisse Dromain
Clarisse Dromain
NFNeil Fleshner
Neil Fleshner
Mike SathekgeMike Sathekge
Mike Sathekge
MPMarianne Ellen Pavel
Marianne Ellen Pavel
VPVikas Prasad
Vikas Prasad
Tumor or target heterogeneity (TH) implies presence of variable cellular populations having different genomic characteristics within the same tumor, or in different tumor sites of the same patient. The challenge is to identify this heterogeneity, as it has emerged as the most common cause of ‘treatment resistance’, to current therapeutic agents. We have focused our discussion on ‘Prostate Cancer’ and ‘Neuroendocrine Tumors’, and looked at the established methods for demonstrating heterogeneity, each with its advantages and drawbacks. Also, the available theranostic radiotracers targeting PSMA and somatostatin receptors combined with targeted systemic agents, have been described. Lu-177 labeled PSMA and DOTATATE are the ‘standard of care’ radionuclide therapeutic tracers for management of progressive treatment-resistant prostate cancer and NET. These approved therapies have shown reasonable benefit in treatment outcome, with improvement in quality of life parameters. Various biomarkers and predictors of response to radionuclide therapies targeting TH which are currently available and those which can be explored have been elaborated in details. Imaging-based features using artificial intelligence (AI) need to be developed to further predict the presence of TH. Also, novel theranostic tools binding to newer targets on surface of cancer cell should be explored to overcome the treatment resistance to current treatment regimens.

Verified
Journal Article
Open access
PDF file
ASAlina Stadermann
Alina Stadermann
MHMarkus Haar
Markus Haar
ARArmin Riecke
Armin Riecke
TMThomas Mayer
Thomas Mayer
CNChristian Neumann
Christian Neumann
HWHanno Witte
Hanno Witte
Hemophagocytic lymphohistiocytosis (HLH) is a rare but in most cases life-threatening immune-mediated disease of the hematopoietic system frequently associated with hematologic neoplasms. Here, we report on a case in which we detected a novel constellation of two missense variants affecting the PRF1 gene, leading to de novo primary HLH. Diagnostics included a comprehensive clinical work-up and standard methods of hematopathology as well as extended molecular genomics based on polymerase chain reaction (PCR) reactions and the calculation of three-dimensional molecule reconstructions of PRF1. Subsequently, a comprehensive review of the literature was performed, which showed that this compound heterozygosity has not been previously described. The patient was a 20-year-old female. Molecular diagnostics revealed two heterozygous missense variants in the PRF1 gene (A91V and R104C) on exon 2. Apart from the finding of two inconclusive genetic variants, all clinical criteria defined by the HLH study group of Histiocyte Society were met at initial presentation. The final diagnosis was made in cooperation with the Consortium of German HLH—reference centers. Here, chemotherapy did not lead to sufficient sustained disease control. Therefore, the decision for allogenic hematopoietic stem cell transplantation (alloHSCT) was made. Hitherto, the duration of response was 6 months. Due to severe and unmanageable hepatic graft-versus-host disease (GvHD), the patient died. We report on a novel constellation of a compound heterozygosity containing two missense variants on exon 2 of the PRF1 gene. To the authors’ best knowledge, this is the first presentation of a primary HLH case harboring this genomic constellation with late-onset clinical manifestation.

Verified
Journal Article
Open access
PDF file
MPManuela Petersen
Manuela Petersen
SSSimone Agnes Schenke
Simone Agnes Schenke
MZMichael Zimny
Michael Zimny
RGRainer Görges
Rainer Görges
MGMichael Grunert
Michael Grunert
OGon behalf of the German TIRADS Study Group
on behalf of the German TIRADS Study Group
Purpose: (i) To examine the criterion taller-than-wide (TTW) for the sonographic assessment of thyroid nodules in areas of iodine deficiency in terms of frequency, anatomical distribution within the thyroid gland and risk of malignancy. (ii) To develop a model for nodule growth in the thyroid gland. Methods: German multicenter study consisting of two parts. In the prospective part, thyroid nodules were sonographically measured in all three dimensions, location within the thyroid gland and contact to a protrusion-like formation (horn) in the dorsal position of thyroid gland was noted. In addition, further sonographic features such as the composition, echogenity, margins and calcifications were investigated. All nodules from the prospective part were assessed for malignancy as part of clinical routine at the decision of the treating physician adhering to institutionally based algorithms. In the retrospective part, only nodules with fine needle aspiration and/or histology were included. The risk of malignancy in TTW nodules was determined by correlating them with cyotological and histological results. Results: Prospective part: out of 441 consecutively evaluated thyroid nodules, 6 were found to be malignant (1.4%, 95% CI 0.6–2.7%). Among the 74 TTW nodules (17%), 1 was malignant (1%, 95% CI 0–4%). TTW nodules were more often located in the dorsal half of the thyroid than non-TTW nodules (factor 2.3, p = 0.01, 95% CI 2.1–2.5) and more often located in close proximity to a horn than non-TTW nodules (factor 3.0, p = 0.01, 95% CI 2.4–3.8). Retrospective part: out of 1315 histologically and/or cytologically confirmed thyroid nodules, 163 TTW nodules were retrieved and retrospectively analyzed. A TTW nodule was 1.7 times more often benign when it was dorsal (95% CI 1.1–2.5) and 2.5 times more often benign when it was associated with a horn (95% CI 1.2–5.3). The overall probability of malignancy for TTW nodules was 38% (95% CI 30–46%) in this highly preselected patient group. Conclusion: TTW nodules are common in iodine deficient areas. They are often located in the dorsal half of the thyroid gland and are frequently associated with a dorsal protrusion-like formation (horn) of the thyroid. Obviously, the shape of benign nodules follows distinct anatomical preconditions within the thyroid gland. The frequency of TTW nodules and their predominant benignity can be explained by a pole concept of goiter growth. The difference between the low malignancy risk of TTW nodules found on a prospective basis and the high risk found retrospectively may be the result of a positive preselection in the latter.

26 September 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SSSimone Agnes Schenke
Simone Agnes Schenke
MPManuela Petersen
Manuela Petersen
RGRainer Görges
Rainer Görges
VRVerena Ruhlmann
Verena Ruhlmann
MZMichael Zimny
Michael Zimny
PSPhilipp Seifert
Philipp Seifert
Purpose: To evaluate the impact of video sequences (cine-loops) on the interobserver agreement (IOA) using risk stratification systems (RSSs) for thyroid nodules (TNs). Methods: Twenty TNs were randomly selected from a large database and evaluated by twelve experienced observers using five different RSSs (Kwak-, ACR-, EU-, Korean-TIRADS, ATA Guidelines). In the first step, the evaluation was conducted based on static ultrasound (US) images in two planes (“static”). Six months later, these cases were reevaluated by the same observers using video sequences in two planes (“cine-loops”). Fleiss’ kappa (κ) was calculated for the IOA analyses. Results: IOA on static was moderate with κ values of 0.46, 0.42, 0.40, 0.45, and 0.38 for the Kwak-, ACR-, EU-, Korean-TIRADS, and ATA Guidelines, respectively, while the IOA on cine-loops was fair with κ values of 0.41, 0.38, 0.37, 0.36, and 0.34 for the Kwak-, ACR-, EU-, Korean-TIRADS, and ATA Guidelines, respectively. The overall IOA was superior in static images versus cine-loops (p = 0.024). Among other findings, the subgroup analyses (related to age, gender, US certificates, number of thyroid US per week, and RSSs experience) particularly showed that the experience of the observers in using RSSs had a significant influence on the IOA. Conclusions: The overall IOA (all twelve observers and all five RSSs) was superior on static US images in comparison to cine-loops. Furthermore, the overall IOA of the five US features revealed superior κ values of the static images over cine-loops. However, this impact was significantly lower when the observers were highly experienced in the use of US RSSs of TNs.

Verified
Journal Article
Open access
SPSebastian Pietzka
Sebastian Pietzka
AGAnne Grieser
Anne Grieser
KWKarsten Winter
Karsten Winter
Alexander SchrammAlexander Schramm
Alexander Schramm
MMMarc Metzger
Marc Metzger
Frank WildeFrank Wilde
Frank Wilde
Study Design: Experimental single-centre study of X-ray absorption using a phantom skull. Objective: This experimental study aimed to compare the radiation doses of different 3D imaging devices used in maxillofacial surgery, including one Multidetector CT (MDCT), two Conebeam CT (CBCT) and four intraoperative 3D C-arms. Methods: Thermoluminescent dosimeters (TLD) were used to determine the absorbed radiation in an Alderson-Rando phantom skull. The phantom skull was positioned in the before mentioned seven devices and a defined 3D facial skull image was acquired. Subsequently, the TLD’S were read out and the effective doses (ED) and the organ doses (OD) were calculated and compared. Results: OD varied significantly between tissues as well as between the 3D X-ray devices. The OD of the 3D C-arms were significantly lower than those of all other devices. The OD of the CT, especially in the standard setting, was the highest. Only by special adjustments of the scan protocol regarding CMF requirements for traumatology, the MDCT could achieve almost equivalent doses as the two tested CBCT-scanners. The calculated effective doses were also lowest for the 3D C-arm devices (11.2 to 129.9 μSv). The ED of the MDCT were significant higher (284.52–844.97 μSv) than in all other devices. The ED of the CBCTs (173.7–184.9) were lower than for MDCT but still higher than those of the 3D C-arms. Conclusions: Intraoperative imaging using 3D C-arm devices is an effective method to verify reduction results in maxillofacial surgery intraoperatively with significantly lower ED than postoperatively CBCT and MDCT imaging.