Ryszard Piramidowicz

Prof. Ryszard Piramidowicz

Warsaw University of Technology, Faculty of Electronics and Information Technology
+1
orcid

Research Focus & Metrics

Academic Career Length

31Years (1996-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2023 in Photonics
Verified
Journal Article
Open access
PDF file
Muhammad Ali ButtMuhammad Ali Butt
Muhammad Ali Butt
MSMuhammad Shahbaz
Muhammad Shahbaz
RPRyszard Piramidowicz
Ryszard Piramidowicz
In this work, a racetrack ring resonator (RTRR) integrated with a multimode interferometer (MMI) structure based on a silica–titania (SiO2:TiO2) platform is projected for refractive index sensing application. The typical ring resonator structure requires a gap of ~100 nm to 200 nm between the bus waveguide (WG) and the ring structure which makes it challenging to fabricate a precise device. Thus, the device proposed in this paper can be considered a “gapless” ring resonator structure in which the coupling of light between the ring and bus WG can be achieved via an MMI coupler. A minor change in the refractive index in the vicinity of the MMI structure can trigger a shift in the resonance wavelength of the device. Thus, this simple and fascinating structure can be employed as a refractive index sensor. The device’s sensitivity is ~142.5 nm/RIU in the refractive index range of 1.33 to 1.36 with a figure of merit (FOM) of 78.3. This simple device structure can potentially be fabricated via a low-cost and highly efficient sol–gel process and dip-coating method combined with the nanoimprint lithography (NIL) method.

1 September 1999 in Optical Materials
Verified
Journal Article
Closed access
MMM Malinowski
M Malinowski
RPRyszard Piramidowicz
Ryszard Piramidowicz
ZFZ Frukacz
Z Frukacz
GCG Chadeyron
G Chadeyron
RMR Mahiou
R Mahiou
MJM.F Joubert
M.F Joubert

29 September 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Nikolay KazanskiyNikolay Kazanskiy
Nikolay Kazanskiy
Svetlana N. KhoninaSvetlana N. Khonina
Svetlana N. Khonina
Muhammad Ali ButtMuhammad Ali Butt
Muhammad Ali Butt
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
RPRyszard Piramidowicz
Ryszard Piramidowicz
A multipurpose plasmonic sensor design based on a metal-insulator-metal (MIM) waveguide is numerically investigated in this paper. The proposed design can be instantaneously employed for biosensing and temperature sensing applications. The sensor consists of two simple resonant cavities having a square and circular shape, with the side coupled to an MIM bus waveguide. For biosensing operation, the analytes can be injected into the square cavity while a thermo-optic polymer is deposited in the circular cavity, which provides a shift in resonance wavelength according to the variation in ambient temperature. Both sensing processes work independently. Each cavity provides a resonance dip at a distinct position in the transmission spectrum of the sensor, which does not obscure the analysis process. Such a simple configuration embedded in the single-chip can potentially provide a sensitivity of 700 nm/RIU and −0.35 nm/°C for biosensing and temperature sensing, respectively. Furthermore, the figure of merit (FOM) for the biosensing module and temperature sensing module is around 21.9 and 0.008, respectively. FOM is the ratio between the sensitivity of the device and width of the resonance dip. We suppose that the suggested sensor design can be valuable in twofold ways: (i) in the scenarios where the testing of the biological analytes should be conducted in a controlled temperature environment and (ii) for reducing the influence on ambient temperature fluctuations on refractometric measurements in real-time mode.

12 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
Muhammad Ali ButtMuhammad Ali Butt
Muhammad Ali Butt
MJMarcin Juchniewicz
Marcin Juchniewicz
MSMateusz Słowikowski
Mateusz Słowikowski
ŁKŁukasz Kozłowski
Łukasz Kozłowski
RPRyszard Piramidowicz
Ryszard Piramidowicz
Mid-infrared (MIR) photonic sensors are revolutionizing optical sensing by enabling precise chemical and biological detection through the interrogation of molecules’ unique vibrational modes. This review explores the core principles of MIR photonics, emphasizing the light–matter interactions within the 2–20 µm wavelength range. Additionally, it examines innovative sensor architectures, such as integrated photonic platforms and optical fibers, that enhance sensitivity, specificity, and device miniaturization. The discussion extends to groundbreaking applications in environmental monitoring, medical diagnostics, industrial processes, and security, highlighting the transformative impact of these technologies. This comprehensive overview aims to illuminate the current state-of-the-art while inspiring future developments in MIR photonic sensing.

19 April 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Nikolay KazanskiyNikolay Kazanskiy
Nikolay Kazanskiy
Svetlana N. KhoninaSvetlana N. Khonina
Svetlana N. Khonina
Muhammad Ali ButtMuhammad Ali Butt
Muhammad Ali Butt
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
RPRyszard Piramidowicz
Ryszard Piramidowicz
Optical sensors for biomedical applications have gained prominence in recent decades due to their compact size, high sensitivity, reliability, portability, and low cost. In this review, we summarized and discussed a few selected techniques and corresponding technological platforms enabling the manufacturing of optical biomedical sensors of different types. We discussed integrated optical biosensors, vertical grating couplers, plasmonic sensors, surface plasmon resonance optical fiber biosensors, and metasurface biosensors, Photonic crystal-based biosensors, thin metal films biosensors, and fiber Bragg grating biosensors as the most representative cases. All of these might enable the identification of symptoms of deadly illnesses in their early stages; thus, potentially saving a patient’s life. The aim of this paper was not to render a definitive judgment in favor of one sensor technology over another. We presented the pros and cons of all the major sensor systems enabling the readers to choose the solution tailored to their needs and demands.

31 December 2009 in Journal of Luminescence
Verified
Journal Article
Closed access
MKMariusz Klimczak
Mariusz Klimczak
MMM. Malinowski
M. Malinowski
JSJ. Sarnecki
J. Sarnecki
RPRyszard Piramidowicz
Ryszard Piramidowicz