Andrzej Kaźmierczak

Dr. Andrzej Kaźmierczak

Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2009 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
CCC. F. Carlborg
C. F. Carlborg
KGKristinn Gylfason
Kristinn Gylfason
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
FDFabian Dortu
Fabian Dortu
MBMaria-Jose Bañuls
Maria-Jose Bañuls
WWW. van der Wijngaart
W. van der Wijngaart
We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 × 10−6 refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm−2, to our knowledge the best reported values for integrated planar ring resonators.

1 July 2007 in Materials Today
Verified
Journal Article
Open access
GRG. Roelkens
G. Roelkens
JCJ. Van Campenhout
J. Van Campenhout
JBJ. Brouckaert
J. Brouckaert
DTD. Van Thourhout
D. Van Thourhout
RBR. Baets
R. Baets
CLC. Lagahe-Blanchard
C. Lagahe-Blanchard

1 February 2010 in Optics Express
Verified
Journal Article
Closed access
PDF file
KGKristinn Gylfason
Kristinn Gylfason
CCCarl Fredrik Carlborg
Carl Fredrik Carlborg
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
FDFabian Dortu
Fabian Dortu
HSHans Sohlström
Hans Sohlström
GSGöran Stemme
Göran Stemme
We present an experimental study of an integrated slot-waveguide refractive index sensor array fabricated in silicon nitride on silica. We study the temperature dependence of the slot-waveguide ring resonator sensors and find that they show a low temperature dependence of −16.6 pm/K, while at the same time a large refractive index sensitivity of 240 nm per refractive index unit. Furthermore, by using on-chip temperature referencing, a differential temperature sensitivity of only 0.3 pm/K is obtained, without individual sensor calibration. This low value indicates good sensor-to-sensor repeatability, thus enabling use in highly parallel chemical assays. We demonstrate refractive index measurements during temperature drift and show a detection limit of 8.8 × 10−6 refractive index units in a 7 K temperature operating window, without external temperature control. Finally, we suggest the possibility of athermal slot-waveguide sensor design.

1 January 2008 in Optics Express
Verified
Journal Article
Closed access
PDF file
GMGuillaume Maire
Guillaume Maire
LVLaurent Vivien
Laurent Vivien
GSGuillaume Sattler
Guillaume Sattler
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
BSBenito Sanchez
Benito Sanchez
DHDaniel Hill
Daniel Hill
High efficiency surface grating couplers for silicon nitride waveguides have been designed, fabricated, and characterized. Coupling efficiencies exceeding 60% are reported at a wavelength of 1.31 µm, as well as angular and wavelength -3 dB tolerances of 4° and 50 nm, respectively. When the wavelength is increased from 1310 nm to 1450 nm the coupling efficiency progressively decreases but remains above 20% at 1450 nm. The influence of the duty ratio of the grating has also been investigated: maximum coupling efficiency was obtained at 50% duty ratio.

29 September 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Nikolay KazanskiyNikolay Kazanskiy
Nikolay Kazanskiy
Svetlana N. KhoninaSvetlana N. Khonina
Svetlana N. Khonina
Muhammad Ali ButtMuhammad Ali Butt
Muhammad Ali Butt
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
RPRyszard Piramidowicz
Ryszard Piramidowicz
A multipurpose plasmonic sensor design based on a metal-insulator-metal (MIM) waveguide is numerically investigated in this paper. The proposed design can be instantaneously employed for biosensing and temperature sensing applications. The sensor consists of two simple resonant cavities having a square and circular shape, with the side coupled to an MIM bus waveguide. For biosensing operation, the analytes can be injected into the square cavity while a thermo-optic polymer is deposited in the circular cavity, which provides a shift in resonance wavelength according to the variation in ambient temperature. Both sensing processes work independently. Each cavity provides a resonance dip at a distinct position in the transmission spectrum of the sensor, which does not obscure the analysis process. Such a simple configuration embedded in the single-chip can potentially provide a sensitivity of 700 nm/RIU and −0.35 nm/°C for biosensing and temperature sensing, respectively. Furthermore, the figure of merit (FOM) for the biosensing module and temperature sensing module is around 21.9 and 0.008, respectively. FOM is the ratio between the sensitivity of the device and width of the resonance dip. We suppose that the suggested sensor design can be valuable in twofold ways: (i) in the scenarios where the testing of the biological analytes should be conducted in a controlled temperature environment and (ii) for reducing the influence on ambient temperature fluctuations on refractometric measurements in real-time mode.

19 April 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Nikolay KazanskiyNikolay Kazanskiy
Nikolay Kazanskiy
Svetlana N. KhoninaSvetlana N. Khonina
Svetlana N. Khonina
Muhammad Ali ButtMuhammad Ali Butt
Muhammad Ali Butt
Andrzej KaźmierczakAndrzej Kaźmierczak
Andrzej Kaźmierczak
RPRyszard Piramidowicz
Ryszard Piramidowicz
Optical sensors for biomedical applications have gained prominence in recent decades due to their compact size, high sensitivity, reliability, portability, and low cost. In this review, we summarized and discussed a few selected techniques and corresponding technological platforms enabling the manufacturing of optical biomedical sensors of different types. We discussed integrated optical biosensors, vertical grating couplers, plasmonic sensors, surface plasmon resonance optical fiber biosensors, and metasurface biosensors, Photonic crystal-based biosensors, thin metal films biosensors, and fiber Bragg grating biosensors as the most representative cases. All of these might enable the identification of symptoms of deadly illnesses in their early stages; thus, potentially saving a patient’s life. The aim of this paper was not to render a definitive judgment in favor of one sensor technology over another. We presented the pros and cons of all the major sensor systems enabling the readers to choose the solution tailored to their needs and demands.