Carlo Menon

Prof. Carlo Menon

ETH Zurich, Zürich, Switzerland
+1
orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2015 in Energy Policy
Verified
Journal Article
Closed access
CCChiara Criscuolo
Chiara Criscuolo
Carlo MenonCarlo Menon
Carlo Menon

26 August 2010 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
ZKZeeshan O Khokhar
Zeeshan O Khokhar
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Background: Surface electromyography (sEMG) signals have been used in numerous studies for the classification of hand gestures and movements and successfully implemented in the position control of different prosthetic hands for amputees. sEMG could also potentially be used for controlling wearable devices which could assist persons with reduced muscle mass, such as those suffering from sarcopenia. While using sEMG for position control, estimation of the intended torque of the user could also provide sufficient information for an effective force control of the hand prosthesis or assistive device. This paper presents the use of pattern recognition to estimate the torque applied by a human wrist and its real-time implementation to control a novel two degree of freedom wrist exoskeleton prototype (WEP), which was specifically developed for this work. Methods: Both sEMG data from four muscles of the forearm and wrist torque were collected from eight volunteers by using a custom-made testing rig. The features that were extracted from the sEMG signals included root mean square (rms) EMG amplitude, autoregressive (AR) model coefficients and waveform length. Support Vector Machines (SVM) was employed to extract classes of different force intensity from the sEMG signals. After assessing the off-line performance of the used classification technique, the WEP was used to validate in real-time the proposed classification scheme. Results: The data gathered from the volunteers were divided into two sets, one with nineteen classes and the second with thirteen classes. Each set of data was further divided into training and testing data. It was observed that the average testing accuracy in the case of nineteen classes was about 88% whereas the average accuracy in the case of thirteen classes reached about 96%. Classification and control algorithm implemented in the WEP was executed in less than 125 ms. Conclusions: The results of this study showed that classification of EMG signals by separating different levels of torque is possible for wrist motion and the use of only four EMG channels is suitable. The study also showed that SVM classification technique is suitable for real-time classification of sEMG signals and can be effectively implemented for controlling an exoskeleton device for assisting the wrist.

1 February 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Xianta JiangXianta Jiang
Xianta Jiang
LMLukas-Karim Merhi
Lukas-Karim Merhi
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Whereas pressure sensors increasingly have received attention as a non-invasive interface for hand gesture recognition, their performance has not been comprehensively evaluated. This work examined the performance of hand gesture classification using Force Myography (FMG) and surface Electromyography (sEMG) technologies by performing 3 sets of 48 hand gestures using a prototyped FMG band and an array of commercial sEMG sensors worn both on the wrist and forearm simultaneously. The results show that the FMG band achieved classification accuracies as good as the high quality, commercially available, sEMG system on both wrist and forearm positions; specifically, by only using 8 Force Sensitive Resisters (FSRs), the FMG band achieved accuracies of 91.2% and 83.5% in classifying the 48 hand gestures in cross-validation and cross-trial evaluations, which were higher than those of sEMG (84.6% and 79.1%). By using all 16 FSRs on the band, our device achieved high accuracies of 96.7% and 89.4% in cross-validation and cross-trial evaluations.

19 April 2019 in Cellulose
Verified
Journal Article
Closed access
PDF file
YLYucheng Liu
Yucheng Liu
JXJun Xie
Jun Xie
NWNa Wu
Na Wu
Yunhai MaYunhai Ma
Yunhai Ma
Carlo MenonCarlo Menon
Carlo Menon
JTJin Tong
Jin Tong

20 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Information about limb movements can be used for monitoring physical activities or for human-machine-interface applications. In recent years, a technique called Force Myography (FMG) has gained ever-increasing traction among researchers to extract such information. FMG uses force sensors to register the variation of muscle stiffness patterns around a limb during different movements. Using machine learning algorithms, researchers are able to predict many different limb activities. This review paper presents state-of-art research and development on FMG technology in the past 20 years. It summarizes the research progress in both the hardware design and the signal processing techniques. It also discusses the challenges that need to be solved before FMG can be used in an everyday scenario. This paper aims to provide new insight into FMG technology and contribute to its advancement.

20 February 2022 in Advanced Science
Verified
Journal Article
Open access
PDF file
YWYinghong Wu
Yinghong Wu
YLYang Luo
Yang Luo
TCTyler J. Cuthbert
Tyler J. Cuthbert
ASAlexander Shokurov
Alexander Shokurov
PCPaul Chu
Paul Chu
Carlo MenonCarlo Menon
Carlo Menon
Flexible triboelectric nanogenerators (TENGs) have attracted increasing interest since their advent in 2012. In comparison with other flexible electrodes, hydrogels possess transparency, stretchability, biocompatibility, and tunable ionic conductivity, which together provide great potential as current collectors in TENGs for wearable applications. The development of hydrogel‐based TENGs (H‐TENGs) is currently a burgeoning field but research efforts have lagged behind those of other common flexible TENGs. In order to spur research and development of this important area, a comprehensive review that summarizes recent advances and challenges of H‐TENGs will be very useful to researchers and engineers in this emerging field. Herein, the advantages and types of hydrogels as soft ionic conductors in TENGs are presented, followed by detailed descriptions of the advanced functions, enhanced output performance, as well as flexible and wearable applications of H‐TENGs. Finally, the challenges and prospects of H‐TENGs are discussed.