Xianta Jiang

Dr. Xianta Jiang

Memorial University of Newfoundland, Canada
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Medical Engineering & Physics
Verified
Journal Article
Closed access
Xianta JiangXianta Jiang
Xianta Jiang
LMLukas-Karim Merhi
Lukas-Karim Merhi
ZXZhen Gang Xiao
Zhen Gang Xiao
Carlo MenonCarlo Menon
Carlo Menon
Whereas pressure sensors increasingly have received attention as a non-invasive interface for hand gesture recognition, their performance has not been comprehensively evaluated. This work examined the performance of hand gesture classification using Force Myography (FMG) and surface Electromyography (sEMG) technologies by performing 3 sets of 48 hand gestures using a prototyped FMG band and an array of commercial sEMG sensors worn both on the wrist and forearm simultaneously. The results show that the FMG band achieved classification accuracies as good as the high quality, commercially available, sEMG system on both wrist and forearm positions; specifically, by only using 8 Force Sensitive Resisters (FSRs), the FMG band achieved accuracies of 91.2% and 83.5% in classifying the 48 hand gestures in cross-validation and cross-trial evaluations, which were higher than those of sEMG (84.6% and 79.1%). By using all 16 FSRs on the band, our device achieved high accuracies of 96.7% and 89.4% in cross-validation and cross-trial evaluations.

4 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Xianta JiangXianta Jiang
Xianta Jiang
CNChristopher Napier
Christopher Napier
BHBrett Hannigan
Brett Hannigan
JEJanice J. Eng
Janice J. Eng
Carlo MenonCarlo Menon
Carlo Menon
The vertical ground reaction force (vGRF) and its passive and active peaks are important gait parameters and of great relevance for musculoskeletal injury analysis and prevention, the detection of gait abnormities, and the evaluation of lower-extremity prostheses. Most currently available methods to estimate the vGRF require a force plate. However, in real-world scenarios, gait monitoring would not be limited to a laboratory setting. This paper reports a novel solution using machine learning algorithms to estimate the vGRF and the timing and magnitude of its peaks from data collected by a single inertial measurement unit (IMU) on one of the lower limb locations. Nine volunteers participated in this study, walking on a force plate-instrumented treadmill at various speeds. Four IMUs were worn on the foot, shank, distal thigh, and proximal thigh, respectively. A random forest model was employed to estimate the vGRF from data collected by each of the IMUs. We evaluated the performance of the models against the gold standard measurement of the vGRF generated by the treadmill. The developed model achieved a high accuracy with a correlation coefficient, root mean square error, and normalized root mean square error of 1.00, 0.02 body weight (BW), and 1.7% in intra-participant testing, and 0.97, 0.10 BW, and 7.15% in inter-participant testing, respectively, for the shank location. The difference between the reference and estimated passive force peak values was 0.02 BW and 0.14 BW with a delay of −0.14% and 0.57% of stance duration for the intra- and inter-participant testing, respectively; the difference between the reference and estimated active force peak values was 0.02 BW and 0.08 BW with a delay of 0.45% and 1.66% of stance duration for the intra- and inter-participant evaluation, respectively. We concluded that vertical ground reaction force can be estimated using only a single IMU via machine learning algorithms. This research sheds light on the development of a portable wearable gait monitoring system reporting the real-time vGRF in real-life scenarios.

28 December 2024 in Pattern Recognition
Verified
Journal Article
Closed access
WLWanglong Lu
Wanglong Lu
JWJikai Wang
Jikai Wang
TWTao Wang
Tao Wang
KZKaihao Zhang
Kaihao Zhang
Xianta JiangXianta Jiang
Xianta Jiang
HZHanli Zhao
Hanli Zhao

18 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
JLJiaoyang Lu
Jiaoyang Lu
Ting ZouTing Zou
Ting Zou
Xianta JiangXianta Jiang
Xianta Jiang
Inverse kinematics problems (IKP) are ubiquitous in robotics for improved robot control in widespread applications. However, the high non-linearity, complexity, and equation coupling of a general six-axis robotic manipulator pose substantial challenges in solving the IKP precisely and efficiently. To address this issue, we propose a novel approach based on neural network (NN) with numerical error minimization in this paper. Within our framework, the complexity of IKP is first simplified by a strategy called joint space segmentation, with respective training data generated by forward kinematics. Afterwards, a set of multilayer perception networks (MLP) are established to learn from the foregoing data in order to fit the goal function piecewise. To reduce the computational cost of the inference process, a set of classification models is trained to determine the appropriate forgoing MLPs for predictions given a specific input. After the initial solution is sought, being improved with a prediction error minimized, the refined solution is finally achieved. The proposed methodology is validated via simulations on Xarm6—a general 6 degrees of freedom manipulator. Results further verify the feasibility of NN for IKP in general cases, even with a high-precision requirement. The proposed algorithm has showcased enhanced efficiency and accuracy compared to NN-based approaches reported in the literature.

21 April 2018 in Sensors
Verified
Journal Article
Open access
PDF file
Xianta JiangXianta Jiang
Xianta Jiang
KCKelvin Chu
Kelvin Chu
MKMahta Khoshnam
Mahta Khoshnam
Carlo MenonCarlo Menon
Carlo Menon
(1) Background: Quantitative evaluation of gait parameters can provide useful information for constructing individuals’ gait profile, diagnosing gait abnormalities, and better planning of rehabilitation schemes to restore normal gait pattern. Objective determination of gait phases in a gait cycle is a key requirement in gait analysis applications; (2) Methods: In this study, the feasibility of using a force myography-based technique for a wearable gait phase detection system is explored. In this regard, a force myography band is developed and tested with nine participants walking on a treadmill. The collected force myography data are first examined sample-by-sample and classified into four phases using Linear Discriminant Analysis. The gait phase events are then detected from these classified samples using a set of supervisory rules; (3) Results: The results show that the force myography band can correctly detect more than 99.9% of gait phases with zero insertions and only four deletions over 12,965 gait phase segments. The average temporal error of gait phase detection is 55.2 ms, which translates into 2.1% error with respect to the corresponding labelled stride duration; (4) Conclusions: This proof-of-concept study demonstrates the feasibility of force myography techniques as viable solutions in developing wearable gait phase detection systems.

1 November 2015 in International Journal of Human-Computer Studies
Verified
Journal Article
Closed access
Xianta JiangXianta Jiang
Xianta Jiang
BZBin Zheng
Bin Zheng
RBRoman Bednarik
Roman Bednarik
MAM. Stella Atkins
M. Stella Atkins