Om Prakash Singh

Mr. Om Prakash Singh


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 January 2018 in Journal of Breath Research
Verified
Journal Article
Open access
PDF file
OSOm Prakash Singh
Om Prakash Singh
THTeo Aik Howe
Teo Aik Howe
MMM. B. Malarvili
M. B. Malarvili
The development of a human respiration carbon dioxide (CO2) measurement device to evaluate cardiorespiratory status inside and outside a hospital setting has proven to be a challenging area of research over the few last decades. Hence, we report a real-time, user operable CO2 measurement device using an infrared CO2 sensor (Arduino Mega2560) and a thin film transistor (TFT, 3.5″), incorporated with low pass (cut-off frequency, 10 Hz) and moving average (span, 8) filters. The proposed device measures features such as partial end-tidal carbon dioxide (EtCO2), respiratory rate (RR), inspired carbon dioxide (ICO2), and a newly proposed feature—Hjorth activity—that annotates data with the date and time from a real-time clock, and is stored onto a secure digital (SD) card. Further, it was tested on 22 healthy subjects and the performance (reliability, validity and relationship) of each feature was established using (1) an intraclass correlation coefficient (ICC), (2) standard error measurement (SEM), (3) smallest detectable difference (SDD), (4) Bland–Altman plot, and (5) Pearson’s correlation (r). The SEM, SDD, and ICC values for inter- and intra-rater reliability were less than 5% and more than 0.8, respectively. Further, the Bland–Altman plot demonstrates that mean differences ± standard deviations for a set limit were 0.30 ± 0.77 mmHg, −0.34 ± 1.41 mmHg and 0.21 ± 0.64 breath per minute (bpm) for CO2, EtCO2 and RR. The findings revealed that the developed device is highly reliable, providing valid measurements for CO2, EtCO2, ICO2 and RR, and can be used in clinical settings for cardiorespiratory assessment. This research also demonstrates that EtCO2 and RR (r, −0.696) are negatively correlated while EtCO2 and activity (r, 0.846) are positively correlated. Thus, simultaneous measurement of these features may possibly assist physicians in understanding the subject’s cardiopulmonary status. In future, the proposed device will be tested with asthmatic patients for use as an early screening tool outside a hospital setting.

1 September 2021 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
OSOm Prakash Singh
Om Prakash Singh
MVMarta Vallejo
Marta Vallejo
IEIsmail M. El-Badawy
Ismail M. El-Badawy
AAAli Aysha
Ali Aysha
JMJagannathan Madhanagopal
Jagannathan Madhanagopal
Ahmad AthifAhmad Athif
Ahmad Athif

8 December 2023 in Advanced Materials Technologies
Verified
Journal Article
Open access
OSOm Prakash Singh
Om Prakash Singh
ABAndrea Bocchino
Andrea Bocchino
TGTheo Guillerm
Theo Guillerm
YHYuan Hu
Yuan Hu
FSFrank Stam
Frank Stam
Conor O'mahonyConor O'mahony
Conor O'mahony
Microneedle‐based electrodes have attracted significant attention due to their potential applications in high‐quality, long‐term electrophysiological monitoring. In this study, micromoulding technology is used to develop a flexible, conductive fabric microneedle (CF–MN) electrode by bonding a conductive textile to polymeric microneedle arrays. The resulting electrode conforms to the curved surfaces of the body, and the use of a conductive textile backing reduces metallization time and costs by 50% over double‐sided dry electrodes. The electrode‐skin impedance of the CF–MN electrodes is significantly lower than that of gel electrodes over a wide frequency range, and tests on healthy volunteers, both at rest and under a range of ambulatory conditions, showed that the electrodes are capable of acquiring electrocardiography (ECG) and electromyography (EMG) signals that have a comparable kurtosis and signal‐to‐noise ratio to those recorded using conventional electrodes, but without the need for skin preparation or the use of a wet gel. The biomechanical properties of the electrode are also characterized. This is the first demonstration of CF–MN electrodes that can ultimately be integrated into clothing, which in turn can facilitate personalized cardiac health management by enabling continuous, long‐term ECG/EMG monitoring during daily activities.

20 September 2018 in IEEE Access
Verified
Journal Article
Open access
OSOm Prakash Singh
Om Prakash Singh
Ramaswamy PalaniappanRamaswamy Palaniappan
Ramaswamy Palaniappan
MMMb Malarvili
Mb Malarvili
Currently, carbon dioxide (CO 2 waveforms measured by capnography are used to estimate respiratory rate and end-tidal CO 2 (EtCO 2 ) in the clinic. However, the shape of the CO 2 signal carries significant diagnostic information about the asthmatic condition. Previous studies have shown a strong correlation between various features that quantitatively characterize the shape of CO 2 signal and are used to discriminate asthma from non-asthma using pulmonary function tests, but no reliable progress was made, and no translation into clinical practice has been achieved. Therefore, this paper reports a relatively simple signal processing algorithm for automatic differentiation of asthma and non-asthma. CO 2 signals were recorded from 30 non-asthmatic and 43 asthmatic patients. Each breath cycle was decomposed into subcycles, and features were computationally extracted. Thereafter, feature selection was performed using the area ( $A_{z}$ ) under the receiver operating characteristics curve analysis. A classification was performed via a leave-one-out cross-validation procedure by employing a support vector machine. Our results show maximum screening capabilities for upward expiration ( $AR_{1}$ ), downward inspiration ( $AR_{2}$ ), and the sum of $AR_{1}$ and $AR_{2}$ , with an $A_{z}$ of 0.892, 0.803, and 0.793, respectively. The proposed method obtained an average accuracy of 94.52%, sensitivity of 97.67%, and specificity of 90% for discrimination of asthma and non-asthma. The proposed method allows for automatic classification of asthma and non-asthma condition by analyzing the shape of the CO 2 waveform. The developed method may possibly be incorporated in real-time for assessment and management of the asthmatic conditions.

25 October 2018 in Technology and Health Care
Verified
Journal Article
Closed access
PDF file
OSOm Prakash Singh
Om Prakash Singh
IAIsmail Bin Ahmed
Ismail Bin Ahmed
MMM.B. Malarvili
M.B. Malarvili
BACKGROUND: Assessment of asthma outside of the hospital using a patient independent device is highly in demand due to the limitation of existing devices, which are manual and unreliable if patients are not cooperative. OBJECTIVE: The study aims to v

14 January 2022 in IEEE Access
Verified
Journal Article
Open access
IEIsmail M. El-Badawy
Ismail M. El-Badawy
ZOZaid Omar
Zaid Omar
OSOm Prakash Singh
Om Prakash Singh
Capnogram signal analysis has received considerable attention owing to its important applications in assessing cardiopulmonary functions. However, the automatic elimination of deformed parts of a capnogram waveform remains an open research problem. Herein, we introduce an automatic classification approach for discriminating artefact-free (regular) and distorted (irregular) segments of capnogram signals. The proposed features include Hjorth parameters and mean absolute deviation (MAD). The main advantage of these features is their simplicity, such that they can be employed in a computationally efficient machine learning algorithm. MATLAB simulation is conducted on 100 regular and 100 irregular segments of capnogram to extract the proposed and existing features, which are ranked based on the Pearson correlation coefficient, ${p}$ -value and area under receiver operating characteristic (ROC) curve. The naive Bayes, decision tree, random forest and support vector machine (SVM) classifiers are fed by the relatively highly ranked features, and the classification performance is assessed via ten-fold cross-validation. Besides the linear kernel SVM, the radial basis function (RBF) and polynomial kernel functions with different orders are also included in the current experiment. Results revealed the effectiveness of the Hjorth activity and MAD attributes when used with the fourth-order polynomial kernel-SVM classifier. The achieved accuracy, precision and specificity are 89%, 92.1%, and 91% outperforming the existing method by 2.5%, 5.6% and 7%, respectively. The simplicity of the proposed time-domain features is confirmed by the average total computational time of features extraction and classification phases which is only 13 ms instead of 19 ms in the case of incorporating both time- and frequency-domain features, indicating a reduction of 31.6%. It is envisaged that the proposed approach can be valuable if implemented with capnography devices for real-time and fully automated capnogram-based respiratory assessment. Even so, further research is recommended to enhance the classification performance through exploring more features and/or classifiers.