Hong Miao

Hong Miao


Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 July 2021 in IEEE Access
Verified
Journal Article
Open access
CZChengbi Zeng
Chengbi Zeng
HWHanwen Wang
Hanwen Wang
SLSudan Li
Sudan Li
HMHong Miao
Hong Miao
To improve the robustness and stability of the LCL inverter connected to weak grid, this paper proposes a novel active damping based on voltage of point common coupling ( v pcc ) feedback. A phase lead compensator is proposed in the v pcc feedback loop to compensate system phase margin (PM). Theoretical analysis of the effectiveness, detailed parameter setting, stability analysis for proposed active damping adopting lead compensator, named as LC AD, are all described. Simulation and experiment results show that comparing to conventional high pass filter (HPF) AD, the proposed LC AD provides more effective damping effect for the LCL inverter adopting quasi-proportional resonant (QPR) controller under weak grid.

8 December 2023 in Energies
Verified
Journal Article
Open access
PDF file
WLWenfei Liu
Wenfei Liu
BLBo Luo
Bo Luo
YYYong Yang
Yong Yang
NHNiu Haoming
Niu Haoming
XZXujun Zhang
Xujun Zhang
HMHong Miao
Hong Miao
In this paper, we propose a sensorless control strategy for permanent magnet synchronous motors (PMSMs) based on an adaptive-gain sliding mode observer (ASMO) with precise compensation. Firstly, the observer adopts a saturation function with a continuous boundary layer as the switching function to avoid the delay effect of the low-pass filter. In addition, the adaptive-gain method is designed based on a conventional sliding mode observer (SMO) with constant-gain and a saturation function. The adaptive-gain mathematical model is simplified by establishing a nonlinear feedback channel of an SMO. Secondly, in order to improve the practicability and facilitate debugging, the explicit stability condition of an ASMO is deduced according to Lyapunov’s second method. According to the proposed adaptive method, the chattering caused by the mismatch of the sliding-mode gain is suppressed, and the observable speed range is also improved. Thirdly, the position estimation delay problem of an SMO with a continuous switching function is analyzed in detail from the perspective of frequency characteristics. Then, a precise compensation method is proposed for the delay problem, which greatly improves the position estimation accuracy and the control performance. Finally, the correctness of the theory and the feasibility of the ASMO with precise compensation for the sensorless control of PMSMs are verified by experiments.

16 December 2021 in IEEE Access
Verified
Journal Article
Open access
CZChengbi Zeng
Chengbi Zeng
SLSudan Li
Sudan Li
HWHanwen Wang
Hanwen Wang
HMHong Miao
Hong Miao
This paper proposes a fractional phase compensation(FPC) scheme for proportional resonance in parallel with multirate repetitive control (PRMRC) to suppress the grid-injected current harmonics and improve the stability of LCL inverter under weak grid condition. In the PRMRC, the proportional resonance control is introduced to overcome the disadvantages caused by inherent delay of repetitive control. Moreover, in order to expand the system stability range and improve the adaptability of the PRMRC in the weak grid, a Newton fractional filter is proposed to approximate the fractional part of the phase compensation term. The coefficients of the Newton fractional filter do not need to be adjusted online even when the grid impedance fluctuates, which greatly reduces the computational burden. The stability principle of the fractional phase compensation PRMRC scheme and the detailed parameter setting are discussed in the paper. Both simulation and experiment are carried out and the results verify the feasibility and effectiveness of the fractional phase compensation scheme of PRMRC (FPC-PRMRC) for LCL inverter connected to weak grid.

16 October 2023 in IEEE Access
Verified
Journal Article
Open access
CZChengbi Zeng
Chengbi Zeng
XWXuefeng Wu
Xuefeng Wu
HMHong Miao
Hong Miao
HDHaoxiang Duan
Haoxiang Duan
In the multi-paralleled grid-connected inverters system, harmonic oscillations may be deteriorated or even lead to system instability by the coupling between the inverters and the grid impedance. This paper presents a quantify method to determine which inverters contribute more to the harmonic instability so that the corresponding inverters can be removed quickly or targeted oscillation suppression measures can be taken to restore the system to stable operation. In the method, a contribution factor ( CF i ) is defined which can quantitatively represent the responsibility of each inverter to system instability. The CF i are calculated by analyzing the variation of system stability margin after different inverters are removed based on the bode diagram, therefore, according to the corresponding CF i , which inverters have a significant impact on harmonic instability can be determined under different grid impedances. Besides used in the parallel system with different types of inverters (PSDI), the CF i can also be used for the parallel system with identical inverters (PSII) to determine the number of inverters that need to be removed to restore the system to stable operation. The reasonableness and effectiveness of the proposed method are verified by simulation results.

13 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
ZCZeng Chengbi
Zeng Chengbi
SLSudan Li
Sudan Li
HWHanwen Wang
Hanwen Wang
HMHong Miao
Hong Miao
Repetitive control (RC) is gradually used in inverters tied with weak grid. To achieve the zero steady-state error tracking of inverter current and compensate the harmonic distortion caused by frequency fluctuation, a frequency adaptive (FA) control scheme for LCL-type inverter connected with weak grid is proposed. This scheme adopts a proportional resonance (PR) controller in parallel with RC (PRRC) to overcome the disadvantages caused by RC inherent one-cycle time delay. A fractional delay (FD) filter based on the Newton structure is proposed to approximate the fraction item of fs/f, where fs and f are sample frequency and grid frequency, respectively. The structure of the proposed FD filter is relatively simple; moreover, coefficients of the filter maintain constant so as not to need online tuning even when grid frequency fluctuates, which decreases the computational burden considerably. The feasibility and effectiveness of the proposed FA control scheme, named as Newton-FAPRRC, are all verified by the simulation and experimental results.

6 January 2025 in Journal of Power Electronics
Verified
Journal Article
Closed access
PDF file
CZChengbi Zeng
Chengbi Zeng
YZYuxiang Zhao
Yuxiang Zhao
HMHong Miao
Hong Miao
JSJihao Su
Jihao Su