Zeng Chengbi

Dr. Zeng Chengbi


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2022 in Water Resources Management
Verified
Journal Article
Closed access
PDF file
HMHong Miao
Hong Miao
ZQZhongrui Qiu
Zhongrui Qiu
ZCZeng Chengbi
Zeng Chengbi

13 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
ZCZeng Chengbi
Zeng Chengbi
SLSudan Li
Sudan Li
HWHanwen Wang
Hanwen Wang
HMHong Miao
Hong Miao
Repetitive control (RC) is gradually used in inverters tied with weak grid. To achieve the zero steady-state error tracking of inverter current and compensate the harmonic distortion caused by frequency fluctuation, a frequency adaptive (FA) control scheme for LCL-type inverter connected with weak grid is proposed. This scheme adopts a proportional resonance (PR) controller in parallel with RC (PRRC) to overcome the disadvantages caused by RC inherent one-cycle time delay. A fractional delay (FD) filter based on the Newton structure is proposed to approximate the fraction item of fs/f, where fs and f are sample frequency and grid frequency, respectively. The structure of the proposed FD filter is relatively simple; moreover, coefficients of the filter maintain constant so as not to need online tuning even when grid frequency fluctuates, which decreases the computational burden considerably. The feasibility and effectiveness of the proposed FA control scheme, named as Newton-FAPRRC, are all verified by the simulation and experimental results.

17 July 2022 in Entropy
Verified
Journal Article
Open access
PDF file
ACAobing Chi
Aobing Chi
ZCZeng Chengbi
Zeng Chengbi
YGYufu Guo
Yufu Guo
HMHong Miao
Hong Miao
In order to overcome the spectral interference of the conventional Fourier transform in the International Electrotechnical Commission framework, this paper introduces a Bregman-split-based compressive sensing (BSCS) method to estimate the Taylor–Fourier coefficients in a multi-frequency dynamic phasor model. Considering the DDC component estimation, this paper transforms the phasor problem into a compressive sensing model based on the regularity and sparsity of the dynamic harmonic signal distribution. It then derives an optimized hybrid regularization algorithm with the Bregman split method to reconstruct the dynamic phasor estimation. The accuracy of the model was verified by using the cross entropy to measure the distribution differences of values. Composite tests derived from the dynamic phasor test conditions were then used to verify the potentialities of the BSCS method. Simulation results show that the algorithm can alleviate the impact of dynamic signals on phasor estimation and significantly improve the estimation accuracy, which provides a theoretical basis for P-class phasor measurement units (PMUs).