Aya Takase

Ms. Aya Takase

orcid

Research Focus & Metrics

Academic Career Length

29Years (1998-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

8 July 2021 in Crystals
Verified
Journal Article
Open access
PDF file
ATAya Takase
Aya Takase
TITakuya Ishimoto
Takuya Ishimoto
NMNaotaka Morita
Naotaka Morita
NINaoko IKEO
Naoko IKEO
Takayoshi NakanoTakayoshi Nakano
Takayoshi Nakano
Ti-6Al-4V alloy fabricated by laser powder bed fusion (L-PBF) and electron beam powder bed fusion (EB-PBF) techniques have been studied for applications ranging from medicine to aviation. The fabrication technique is often selected based on the part size and fabrication speed, while less attention is paid to the differences in the physicochemical properties. Especially, the relationship between the evolution of α, α’, and β phases in as-grown parts and the fabrication techniques is unclear. This work systematically and quantitatively investigates how L-PBF and EB-PBF and their process parameters affect the phase evolution of Ti-6Al-4V and residual stresses in the final parts. This is the first report demonstrating the correlations among measured parameters, indicating the lattice strain reduces, and c/a increases, shifting from an α’ to α+β or α structure as the crystallite size of the α or α’ phase increases. The experimental results combined with heat-transfer simulation indicate the cooling rate near the β transus temperature dictates the resulting phase characteristics, whereas the residual stress depends on the cooling rate immediately below the solidification temperature. This study provides new insights into the previously unknown differences in the α, α’, and β phase evolution between L-PBF and EB-PBF and their process parameters.

15 April 2002 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
ATAya Takase
Aya Takase
GFGo Fujinawa
Go Fujinawa
AEAtsushi Ebina
Atsushi Ebina
MHMasao Hirasaka
Masao Hirasaka
ISIkuto Sugiyama
Ikuto Sugiyama

1 March 2001 in Japanese Journal of Applied Physics
Verified
Journal Article
Closed access
AEAtsushi Ebina
Atsushi Ebina
MHMasao Hirasaka
Masao Hirasaka
JIJun Isemoto
Jun Isemoto
ATAya Takase
Aya Takase
GFGo Fujinawa
Go Fujinawa
ISIkuto Sugiyama
Ikuto Sugiyama
A high-performance phase change optical recording disk, which has a five-layered structure, was proposed. This disk has a ZnS adhesion layer between a GeSbTe recording layer and a ZnS–SiO2 second dielectric layer. A 2×105 overwrite cyclability was achieved with the original five-layered phase change optical recording disk. The cross-sectional transmission electron microscope observation and the in-plane X-ray diffraction measurement indicate that both the five-layered disk and the four-layered disk have almost the same crystalline structure. The contact angle measurements, however, indicate that the ZnS adhesion layer improves the adhesive force between the GeSbTe recording layer and the ZnS–SiO2 second dielectric layer. It is considered that the high overwrite cyclability results from this improvement of the adhesive force. Moreover, the electron probe microanalysis results indicate that the ZnS layer acts as a protective layer against the Ge diffusion from the GeSbTe recording layer.

1 January 2024 in Journal of Oral Science
Verified
Journal Article
Open access
PDF file
JKJinah Kim
Jinah Kim
KVKali Vo
Kali Vo
GDGurmukh S. Dhaliwal
Gurmukh S. Dhaliwal
ATAya Takase
Aya Takase
CPCarolyn M Primus
Carolyn M Primus
TKTakashi Komabayashi
Takashi Komabayashi
Purpose: Using X-ray micro-computed tomography (micro-CT), the aim of this study was to measure the porosity of two tricalcium silicate sealers (EndoSequence BC and NeoSealer Flo) applied using three obturation techniques (single-cone, warm-vertical, and cold-lateral) to six single-rooted human teeth.Methods: Six extracted, single-rooted human teeth were shaped with ProTaper Next rotary files and obturated with EndoSequence BC or NeoSealer Flo sealers and gutta-percha (GP) using one of the three techniques above. Micro-CT was used to map the full length of the canals. Deep learning cross-sectional segmentation was used to analyze image slices of the apical (0-2 mm) and coronal (14-16 mm from the apex) regions (n = 230-261 per tooth) for the areas of GP and sealer, as well as porosity. Median (%) with interquartile range of porosity were calculated , and the results were statistically analyzed with the Kruskal-Wallis test.Results: In the apical region, EndoSequence BC had significantly fewer pores than NeoSealer Flo with the single-cone obturation (% median-interquartile range, IQR: 0.00-1.62) and warm-vertical condensation (5.57-10.32) techniques, whereas in the coronal region, NeoSealer Flo had significantly fewer pores than EndoSequence BC with these two techniques (0.39-5.02) and (0.10-0.19), respectively. There was no significant difference in porosity between the two sealers for the cold-lateral condensation technique in both the apical and coronal regions.Conclusion: For optimal obturation, the choice of technique and sealer is critical.

10 August 2018 in Microscopy and Microanalysis
Verified
Journal Article
Closed access
PDF file
ATAya Takase
Aya Takase
TMTom McNulty
Tom McNulty
TFThomas Fitzgibbons
Thomas Fitzgibbons