To determine the cause of negative dysphotopsia using standard ray-tracing techniques and identify the primary and secondary causative factors. Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA. Experimental study. Zemax ray-tracing software was used to evaluate pseudophakic and phakic eye models to show the location of retinal field images from various visual field objects. Phakic retinal field angles (RFAs) were used as a reference for the perceived field locations for retinal images in pseudophakic eyes. In a nominal acrylic pseudophakic eye model with a 2.5 mm diameter pupil, the maximum RFA from rays refracted by the intraocular lens (IOL) was 85.7 degrees and the minimum RFA for rays missing the optic of the IOL was 88.3 degrees, leaving a dark gap (shadow) of 2.6 degrees in the extreme temporal field. The width of the shadow was more prominent for a smaller pupil, a larger angle kappa, an equi-biconvex or plano-convex IOL shape, and a smaller axial distance from iris to IOL and with the anterior capsule overlying the nasal IOL. Secondary factors included IOL edge design, material, diameter, decentration, tilt, and aspheric surfaces. Standard ray-tracing techniques showed that a shadow is present when there is a gap between the retinal images formed by rays missing the optic of the IOL and rays refracted by the IOL. Primary and secondary factors independently affected the width and location of the gap (or overlap). The ray tracing also showed a constriction and double retinal imaging in the extreme temporal visual field.
An intraocular lens (IOL) replaces the natural crystalline lens during cataract surgery, and although the vast majority of implants have simple optics, “advanced technology” IOLs have multifocal and extended depth of focus (EDOF) properties. Optical concepts are evaluated here, with image contrast, focal range, and unwanted visual phenomena being the primary concerns. Visual phenomena with earlier bifocal diffractive lenses led to alternative diffractive designs (trifocals, etc.) and also to exploring increasing the depth of focus for monofocal IOLs using refractive methods, where although the defocus range might be more modest, visual phenomena are much less obvious. The designs cover a range of possibilities that might provide the best overall vision for patients with differing motivations, needs, and sensitivity to visual side effects.
11 November 2014 in Journal of the Optical Society of America A
Some intraocular lens (IOL) patients report seeing “dark shadows” at visual angles that are larger than 60°–70°. Raytrace models of the pseudophakic eye show that light starts to miss the IOL at large visual angles because the implant diameter of about 6 mm is much smaller than the natural crystalline lens diameter of 9.5 mm. This light forms a second displaced image on the peripheral retina. To evaluate the appearance of the image, raytrace software was used to image an illuminated window onto the highly curved retina, and a method was developed to project the image back to object space for evaluation on a flat surface. Only a single schematic eye was evaluated monochromatically and the low resolution of the peripheral retina was not modeled, but the simulated images depict a shadow-like phenomenon at similar visual angles to reports of “negative dysphotopsia.”
19 February 2019 in Journal of the Optical Society of America A
Simulated images were generated using an extended source to illustrate peripheral dark shadows in pseudophakic eye models. The shadows are a consequence of the intraocular lens being much smaller than the natural crystalline lens, which limits the extent of the focused image. Compensation is made for the cosine intensity falloff due to pupil obliquity, and the images are envisaged as being displayed on polar plots of visual angle corresponding to approximate retinal locations. Additional retinal illumination from light missing the lens reduces the shadow effect as the pupil diameter increases, in agreement with clinical observations. Lenses with two different cross-sectional profiles were evaluated, which both have shadows at about 85°, but with different characteristics. The iris thickness was found to affect the shadows by occluding peripheral rays. Images were also generated for a point source with a 5 mm pupil, where a double image is created for visual angles as low as 50°, which may contribute to visual phenomena at night. This type of modeling may help with patient evaluations and discussions.
Nodal points are defined using parallel object and image rays at very small angles to the optical axis, and Johann Listing described them when characterizing the eye in 1845. They are only distinct from principal points when there is a refractive index difference, but Reginald Clay used the term “nodal slide” in 1904 for equipment that uses lens rotation when measuring a lens focal length in air. Over time, sketches of nodal rays at large angles have become common, and these perhaps appear to support observations that input angles to the eye match image angles measured to the nodal point. Raytrace calculations confirm that this is correct for very large angles, but the relationship comes from the cornea curving around, towards incoming light, angles being rescaled at the exit pupil by a constant factor, and then the retina curving around to meet the image rays. The eye has high linearity, with 1:1 angular scaling occurring at approximately the nodal point, but ray bundles passing through the pupil center, rather than paraxial nodal rays, define the optical properties.