JI HYEON KIM

Ms. JI HYEON KIM


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
HLHeewon Lim
Heewon Lim
JKJI HYEON KIM
JI HYEON KIM
HLHyeun-Seung Lee
Hyeun-Seung Lee
USU-Cheul Shin
U-Cheul Shin
Over the past 20 years, net-zero energy house (NZEH) construction costs have steadily decreased because of many reasons, such as technical progress, energy-saving design obligations, and dramatic cost reductions in renewable energy systems, especially solar power systems. Currently, the costs of NZEH are estimated to be about 5% higher than similar-sized houses. These additional costs are mainly for installing PV systems, which can be offset by energy saving costs. This study assessed energy performance and load matching through remote monitoring systems, and energy costs were analyzed for two-family houses. The two houses were all-electric houses and different in both size and location. A 6 kWp grid-connected PV system and 16 kW air source heat pump for space heating and domestic hot water were equally implemented. After data analysis, 100% of the energies were supplied through the PV system for 3 years, thus achieving net-zero energy. According to the Korean residential electricity tariff system, the annual electricity charges were, on average, between USD 105.1 and USD 121.4 after adding demand charges and value-added tax for import electricity charges. The energy cost reduction rate, compared to the same house without a PV system, was about 95%, and the simple payback period of the 6 kW PV system in NZEH was about 6 years. In addition, the annual load cover factor and supply cover factor as load-match indices between electricity generation and the load were in a range of 0.39–0.49 and 0.37–0.42, respectively.

13 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
HLHeewon Lim
Heewon Lim
IKIl Kwon Kim
Il Kwon Kim
JKJI HYEON KIM
JI HYEON KIM
USU-Cheul Shin
U-Cheul Shin
A small-scale grid-connected PV system that is easy to install and is inexpensive as a remote monitoring system may cause economic losses if its failure is not found and it is left unattended for a long time. Thus, in this study, we developed a low-cost fault detection remote monitoring system for small-scale grid-connected PV systems. This active monitoring system equipped with a simulation-based fault detection algorithm accurately predicts AC power under normal operating conditions and notifies its failure when the measured power is abnormally low. In order to lower the cost, we used a single board computer (SBC) with edge computing as a data server and designed a monitoring system using openHAB, an open-source software. Additionally, we used the Shewhart control chart as a fault detection criterion and the ratio between the measured and predicted ac power for the normal operation data as an observation. As a result of the verification test for the actual grid-connected PV system, it was confirmed that the developed remote monitoring system was able to accurately identify the system failures in real-time, such as open circuit, short circuit, partial shading, etc.

27 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
LSLee Songseop
Lee Songseop
JKJI HYEON KIM
JI HYEON KIM
HLHeewon Lim
Heewon Lim
USU-Cheul Shin
U-Cheul Shin
This study evaluates the operational performance and carbon emissions of an air-source heat pump (ASHP) system based on a one-year field monitoring campaign conducted at a single-family detached house in Gongju, South Korea. The system, equipped with a 9 kW air-to-water ASHP, supplied both space heating (SH) and domestic hot water (DHW), achieving average coefficients of performance (COPs) of 2.27 for SH and 2.06 for DHW. To estimate nominal COPs, a bi-quadratic regression model was developed using manufacturer catalog data and compared against field measurements. The analysis revealed a significant performance decline during winter: a paired t-test using 7119 samples confirmed a statistically significant discrepancy under low-temperature conditions. Annual CO2-equivalent (CO2eq) emissions were also evaluated. Under current grid emission factors, the ASHP system emitted 1532 kgCO2eq—approximately 8.6% more than a condensing gas boiler (1411 kgCO2eq), primarily due to winter performance degradation and the relatively high carbon intensity of electricity. These findings underscore the importance of incorporating actual operating conditions, seasonal variability, and the national electricity emission factor when assessing ASHP performance and life cycle climate performance (LCCP).