Over the past 20 years, net-zero energy house (NZEH) construction costs have steadily decreased because of many reasons, such as technical progress, energy-saving design obligations, and dramatic cost reductions in renewable energy systems, especially solar power systems. Currently, the costs of NZEH are estimated to be about 5% higher than similar-sized houses. These additional costs are mainly for installing PV systems, which can be offset by energy saving costs. This study assessed energy performance and load matching through remote monitoring systems, and energy costs were analyzed for two-family houses. The two houses were all-electric houses and different in both size and location. A 6 kWp grid-connected PV system and 16 kW air source heat pump for space heating and domestic hot water were equally implemented. After data analysis, 100% of the energies were supplied through the PV system for 3 years, thus achieving net-zero energy. According to the Korean residential electricity tariff system, the annual electricity charges were, on average, between USD 105.1 and USD 121.4 after adding demand charges and value-added tax for import electricity charges. The energy cost reduction rate, compared to the same house without a PV system, was about 95%, and the simple payback period of the 6 kW PV system in NZEH was about 6 years. In addition, the annual load cover factor and supply cover factor as load-match indices between electricity generation and the load were in a range of 0.39–0.49 and 0.37–0.42, respectively.

1 August 2018 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Closed access
BKBeob-Jeon Kim
Beob-Jeon Kim
HLHee-Won Lim
Hee-Won Lim
DKDeok-Sung Kim
Deok-Sung Kim
USU-Cheul Shin
U-Cheul Shin

13 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
HLHeewon Lim
Heewon Lim
IKIl Kwon Kim
Il Kwon Kim
JKJI HYEON KIM
JI HYEON KIM
USU-Cheul Shin
U-Cheul Shin
A small-scale grid-connected PV system that is easy to install and is inexpensive as a remote monitoring system may cause economic losses if its failure is not found and it is left unattended for a long time. Thus, in this study, we developed a low-cost fault detection remote monitoring system for small-scale grid-connected PV systems. This active monitoring system equipped with a simulation-based fault detection algorithm accurately predicts AC power under normal operating conditions and notifies its failure when the measured power is abnormally low. In order to lower the cost, we used a single board computer (SBC) with edge computing as a data server and designed a monitoring system using openHAB, an open-source software. Additionally, we used the Shewhart control chart as a fault detection criterion and the ratio between the measured and predicted ac power for the normal operation data as an observation. As a result of the verification test for the actual grid-connected PV system, it was confirmed that the developed remote monitoring system was able to accurately identify the system failures in real-time, such as open circuit, short circuit, partial shading, etc.

30 August 2022 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Open access
JKJi-Hyeon Kim
Ji-Hyeon Kim
HLHyun-Seung Lee
Hyun-Seung Lee
BOByung-Chil Oh
Byung-Chil Oh
USU-Cheul Shin
U-Cheul Shin

27 December 2025 in Energies
Verified
Journal Article
Open access
PDF file
LSLee Songseop
Lee Songseop
JKJI HYEON KIM
JI HYEON KIM
HLHeewon Lim
Heewon Lim
USU-Cheul Shin
U-Cheul Shin
This study evaluates the operational performance and carbon emissions of an air-source heat pump (ASHP) system based on a one-year field monitoring campaign conducted at a single-family detached house in Gongju, South Korea. The system, equipped with a 9 kW air-to-water ASHP, supplied both space heating (SH) and domestic hot water (DHW), achieving average coefficients of performance (COPs) of 2.27 for SH and 2.06 for DHW. To estimate nominal COPs, a bi-quadratic regression model was developed using manufacturer catalog data and compared against field measurements. The analysis revealed a significant performance decline during winter: a paired t-test using 7119 samples confirmed a statistically significant discrepancy under low-temperature conditions. Annual CO2-equivalent (CO2eq) emissions were also evaluated. Under current grid emission factors, the ASHP system emitted 1532 kgCO2eq—approximately 8.6% more than a condensing gas boiler (1411 kgCO2eq), primarily due to winter performance degradation and the relatively high carbon intensity of electricity. These findings underscore the importance of incorporating actual operating conditions, seasonal variability, and the national electricity emission factor when assessing ASHP performance and life cycle climate performance (LCCP).

30 December 2022 in Journal of the Korean Solar Energy Society
Verified
Journal Article
Open access
PDF file
HLHee Won Lim
Hee Won Lim
JKJi Hyun Kim
Ji Hyun Kim
IKIl Kwon Kim
Il Kwon Kim
USU-Cheul Shin
U-Cheul Shin
Air-source heat pumps (ASHPs) have somewhat lower operating performance than groundsource heat pumps (GSHPs), but they have been reported to have low initial investment costs and a great energy-cost-saving effect due to the implementation of net-zero-energy houses. In this study, we analyzed the dynamic behavior and energy performance of equivalent ASHPs in existing low-energy houses installed with GSHPs of 9 kW using TRNSYS dynamic simulation. The house with a total floor area of 194 m 2 was an all-electric house and domestic hot water, space heating, and cooling energy were supplied by the ASHP. To summarize the main results, first, the annual space heating and cooling energy supply of the ASHPs was 7,698 kWh and 2,226 kWh, respectively, and the annual heating COP and cooling EER were 3.4 and 3.1, respectively. Second, the total annual power consumption of the proposed model with ASHPs was 8,218 kWh and the annual power generation of the 6 kWp PV system was 8,682 kWh, which generated a surplus of 464 kWh, achieving net-zero energy. Third, the total annual electricity charge was 249,000 generated by ASHPs (proposal model) connected to the "residential service" grid of KEPCO, which was reduced by approximately 66% compared to the 736,000 generated by the GSHPs (existing model) linked to a "general service" grid. Keywords: 공기열원히트펌프(Air source heat pump), 성능계수(Coefficient of performance), 지열히트펌프(Ground source heat pump), 넷-제로에너지주택(Net-zero energy house), 태 양광발전시스템(Photovoltaic system), 에너지효율비(Energy efficiency ratio) 한국태양에너지학회 논문집