David Atkinson

Prof. David Atkinson

orcid

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2014 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Open access
NBNinon Burgos
Ninon Burgos
MCM. Jorge Cardoso
M. Jorge Cardoso
KTKris Thielemans
Kris Thielemans
MMMarc Modat
Marc Modat
SPStefano Pedemonte
Stefano Pedemonte
SOSebastien Ourselin
Sebastien Ourselin
Attenuation correction is an essential requirement for quantification of positron emission tomography (PET) data. In PET/CT acquisition systems, attenuation maps are derived from computed tomography (CT) images. However, in hybrid PET/MR scanners, magnetic resonance imaging (MRI) images do not directly provide a patient-specific attenuation map. The aim of the proposed work is to improve attenuation correction for PET/MR scanners by generating synthetic CTs and attenuation maps. The synthetic images are generated through a multi-atlas information propagation scheme, locally matching the MRI-derived patient's morphology to a database of MRI/CT pairs, using a local image similarity measure. Results show significant improvements in CT synthesis and PET reconstruction accuracy when compared to a segmentation method using an ultrashort-echo-time MRI sequence and to a simplified atlas-based method.

1 January 1997 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
DADavid Atkinson
David Atkinson
DHD.L.G. Hill
D.L.G. Hill
PSP.N.R. Stoyle
P.N.R. Stoyle
PSPaul Summers
Paul Summers
SKS.F. Keevil
S.F. Keevil
We present the use of an entropy focus criterion to enable automatic focusing of motion corrupted magnetic resonance images. We demonstrate the principle using illustrative examples from cooperative volunteers. Our technique can determine unknown patient motion or use knowledge of motion from other measures as a starting estimate. The motion estimate is used to compensate the acquired data and is iteratively refined using the image entropy. Entropy focuses the whole image principally by favoring the removal of motion induced ghosts and blurring from otherwise dark regions of the image. Using only the image data, and no special hardware or pulse sequences, we demonstrate correction for arbitrary rigid-body translational motion in the imaging plane and for a single rotation. Extension to three-dimensional (3-D) and more general motion should be possible. The algorithm is able to determine volunteer motion well. The mean absolute deviation between algorithm and navigator-echo-determined motion is comparable to the displacement step size used in the algorithm. Local deviations from the recorded motion or navigator-determined motion are explained and we indicate how enhanced focus criteria may be derived. In all cases we were able to compensate images for patient motion, reducing blurring and ghosting.

9 September 2005 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
PBP. G. Batchelor
P. G. Batchelor
DADavid Atkinson
David Atkinson
PIP. Irarrazaval
P. Irarrazaval
DHD. L. G. Hill
D. L. G. Hill
JHJ. Hajnal
J. Hajnal
DLD. Larkman
D. Larkman
Motion of an object degrades MR images, as the acquisition is time‐dependent, and thus k‐space is inconsistently sampled. This causes ghosts. Current motion correction methods make restrictive assumptions on the type of motions, for example, that it is a translation or rotation, and use special properties of k‐space for these transformations. Such methods, however, cannot be generalized easily to nonrigid types of motions, and even rotations in multiple shots can be a problem. Here, a method is presented that can handle general nonrigid motion models. A general matrix equation gives the corrupted image from the ideal object. Thus, inversion of this system allows us to get the ideal image from the corrupted one. This inversion is possible by efficient methods mixing Fourier transforms with the conjugate gradient method. A faster but empirical inversion is discussed as well as methods to determine the motion. Simulated three‐dimensional affine data and two‐dimensional pulsation data and in vivo nonrigid data are used for demonstration. All examples are multishot images where the object moves between shots. The results indicate that it is now possible to correct for nonrigid types of motion that are representative of many types of patient motion, although computation times remain an issue. Magn Reson Med, 2005.

1 September 2002 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
KMK. McLeish
K. McLeish
DHD.L.G. Hill
D.L.G. Hill
DADavid Atkinson
David Atkinson
JBJ.M. Blackall
J.M. Blackall
RRR. Razavi
R. Razavi
This paper describes a quantitative assessment of respiratory motion of the heart and the construction of a model of respiratory motion. Three-dimensional magnetic resonance scans were acquired on eight normal volunteers and ten patients. The volunteers were imaged at multiple positions in the breathing cycle between full exhalation and full inhalation while holding their breath. The exhalation volume was segmented and used as a template to which the other volumes were registered using an intensity-based rigid registration algorithm followed by nonrigid registration. The patients were imaged at inhale and exhale only. The registration results were validated by visual assessment and consistency measurements indicating subvoxel registration accuracy. For all subjects, we assessed the nonrigid motion of the heart at the right coronary artery, right atrium, and left ventricle. We show that the rigid-body motion of the heart is primarily in the craniocaudal direction with smaller displacements in the right-left and anterior-posterior directions; this is in agreement with previous studies. Deformation was greatest for the free wall of the right atrium and the left ventricle; typical deformations were 3-4 mm with deformations of up to 7 mm observed in some subjects. Using the registration results, landmarks on the template surface were mapped to their correct positions through the breathing cycle. Principal component analysis produced a statistical model of the motion and deformation of the heart. We discuss how this model could be used to assist motion correction.

1 April 2015 in Investigative Radiology
Verified
Journal Article
Closed access
EPEleftheria Panagiotaki
Eleftheria Panagiotaki
RCRachel W. Chan
Rachel W. Chan
Nikolaos DikaiosNikolaos Dikaios
Nikolaos Dikaios
HAHashim U. PhD Ahmed
Hashim U. PhD Ahmed
JOJames Msc O’callaghan
James Msc O’callaghan
DADaniel C. Alexander
Daniel C. Alexander
Objective The aim of this study was to demonstrate the feasibility of the recently introduced Vascular, Extracellular, and Restricted Diffusion for Cytometry in Tumours (VERDICT) framework for imaging prostate cancer with diffusion-weighted magnetic resonance imaging (DW-MRI) within a clinical setting. Materials and Methods The VERDICT framework is a noninvasive microstructure imaging technique that combines an in-depth diffusion MRI acquisition with a mathematical model to estimate and map microstructural tissue parameters such as cell size and density and vascular perfusion. In total, 8 patients underwent 3-T MRI using 9 different b values (100–3000 s/mm2). All patients were imaged before undergoing biopsy. Experiments with VERDICT analyzed DW-MRI data from patients with histologically confirmed prostate cancer in areas of cancerous and benign peripheral zone tissue. For comparison, we also fitted commonly used diffusion models such as the apparent diffusion coefficient (ADC), the intravoxel incoherent motion (IVIM), and the kurtosis model. We also investigated correlations of ADC and kurtosis with VERDICT parameters to gain some biophysical insight into the various parameter values. Results Eight patients had prostate cancer in the peripheral zone, with Gleason score 3 + 3 (n = 1), 3 + 4 (n = 6), and 4 + 3 (n = 1). The VERDICT model identified a significant increase in the intracellular and vascular volume fraction estimates in cancerous compared with benign peripheral zone, as well as a significant decrease in the volume of the extracellular-extravascular space (EES) (P = 0.05). This is in agreement with manual segmentation of the biopsies for prostate tissue component analysis, which found proliferation of epithelium, loss of surrounding stroma, and an increase in vasculature. The standard ADC and kurtosis parameters were also significantly different (P = 0.05) between tissue types. There was no significant difference in any of the IVIM parameters (P = 0.11 to 0.29). The VERDICT parametric maps from voxel-by-voxel fitting clearly differentiated cancer from benign regions. Kurtosis and ADC parameters correlated most strongly with VERDICT’s intracellular volume fraction but also moderately with the EES and vascular fractions. Conclusions The VERDICT model distinguished tumor from benign areas, while revealing differences in microstructure descriptors such as cellular, vascular, and EES fractions. The parameters of ADC and kurtosis models also discriminated between cancer and benign regions. However, VERDICT provides more specific information that disentangles the various microstructural features underlying the changes in ADC and kurtosis. These results highlight the clinical potential of the VERDICT framework and motivate the construction of a shorter, clinically viable imaging protocol to enable larger trials leading to widespread translation of the method.

16 August 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MUMuhammad Usman
Muhammad Usman
DADavid Atkinson
David Atkinson
FOFreddy Odille
Freddy Odille
CKChristoph Kolbitsch
Christoph Kolbitsch
GVGhislain Vaillant
Ghislain Vaillant
CPClaudia Prieto
Claudia Prieto
Compressed sensing (CS) has been demonstrated to accelerate MRI acquisitions by reconstructing sparse images of good quality from highly undersampled data. Motion during MR scans can cause inconsistencies in k‐space data, resulting in strong motion artifacts in the reconstructed images. For CS to be useful in these applications, motion correction techniques need to be combined with the undersampled reconstruction. Recently, joint motion correction and CS approaches have been proposed to partially correct for effects of motion. However, the main limitation of these approaches is that they can only correct for affine deformations. In this work, we propose a novel motion corrected CS framework for free‐breathing dynamic cardiac MRI that incorporates a general motion correction formulation directly into the CS reconstruction. This framework can correct for arbitrary affine or nonrigid motion in the CS reconstructed cardiac images, while simultaneously benefiting from highly accelerated MR acquisition. The application of this approach is demonstrated both in simulations and in vivo data for 2D respiratory self‐gated free‐breathing cardiac CINE MRI, using a golden angle radial acquisition. Results show that this approach allows for the reconstruction of respiratory motion corrected cardiac CINE images with similar quality to breath‐held acquisitions. Magn Reson Med 70:504–516, 2013.