Data about the long-term duration of antibodies after SARS-CoV-2 vaccination are still scarce and are important to design vaccination strategies. In this study, 231 healthcare professionals received the two-dose regimen of BNT162b2. Of these, 158 were seronegative and 73 were seropositive at baseline. Samples were collected at several time points. The neutralizing antibodies (NAbs) and antibodies against the nucleocapsid and the spike protein of SARS-CoV-2 were measured. At day 180, a significant antibody decline was observed in seronegative (−55.4% with total antibody assay; −89.6% with IgG assay) and seropositive individuals (−74.8% with total antibody assay; −79.4% with IgG assay). The estimated half-life of IgG from the peak humoral response was 21 days (95% CI: 13–65) in seronegative and 53 days (95% CI: 40–79) in seropositive individuals. The estimated half-life of total antibodies was longer and ranged from 68 days (95% CI: 54–90) to 114 days (95% CI: 87–167) in seropositive and seronegative individuals, respectively. The decline of NAbs was more pronounced (−98.6%) and around 45% of the subjects tested were negative at day 180. Whether this decrease correlates with an equivalent drop in the clinical effectiveness against the virus would require appropriate clinical studies.
Rapid antigen detection (RAD) tests are commonly used for the diagnosis of SARS-CoV-2 infections. However, with the continuous emergence of new variants of concern (VOC), presenting various mutations potentially affecting the nucleocapsid protein, the analytical performances of these assays should be frequently reevaluated. One hundred and twenty samples were selected and tested with both RT-qPCR and six commercial RAD tests that are commonly sold in Belgian pharmacies. Of these, direct whole-genome sequencing identified the strains present in 116 samples, of which 70 were Delta and 46 were Omicron (BA.1 and BA.1.1 sub-lineages, respectively). The sensitivity across a wide range of Ct values (13.5 to 35.7; median = 21.3) ranged from 70.0% to 92.9% for Delta strains and from 69.6% to 78.3% for Omicron strains. When taking swabs with a low viral load (Ct > 25, corresponding to <4.9 log10 copies/mL), only the Roche RAD test showed acceptable performances for the Delta strains (80.0%), while poor performances were observed for the other RAD tests (20.0% to 40.0%). All the tested devices had poor performances for the Omicron samples with a low viral load (0.0% to 23.1%). The poor performances observed with low viral loads, particularly for the Omicron strain, is an important limitation of RAD tests, which is not sufficiently highlighted in the instructions for use of these devices.
Background: Little is known about potential confounding factors influencing the humoral response in individuals having received the BNT162b2 vaccine. Methods: Blood samples from 231 subjects were collected before and 14, 28, and 42 days following coronavirus disease 2019 (COVID-19) vaccination with BNT162b2. Anti-spike receptor-binding-domain protein (anti-Spike/RBD) immunoglobulin G (IgG) antibodies were measured at each time-point. Impact of age, sex, childbearing age status, hormonal therapy, blood group, body mass index and past-history of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection were assessed by multivariable analyses. Results and Conclusions: In naïve subjects, the level of anti-Spike/RBD antibodies gradually increased following administration of the first dose to reach the maximal response at day 28 and then plateauing at day 42. In vaccinated subjects with previous SARS-CoV-2 infection, the plateau was reached sooner (i.e., at day 14). In the naïve population, age had a significant negative impact on anti-Spike/RBD titers at days 14 and 28 while lower levels were observed for males at day 42, when corrected for other confounding factors. Body mass index (BMI) as well as B and AB blood groups had a significant impact in various subgroups on the early response at day 14 but no longer after. No significant confounding factors were highlighted in the previously infected group.
The diagnostic of SARS-CoV-2 infection relies on reverse transcriptase polymerase chain reactions (RT-PCRs) performed on nasopharyngeal (NP) swabs. Nevertheless, false-negative results can be obtained with inadequate sampling procedures, making the use of other biological matrices worthy of investigation. This study aims to evaluate the kinetics of serum N antigens in severe and non-severe patients and compare the clinical performance of serum antigenic assays with NP RT-PCR. Ninety patients were included in the study and monitored for several days. Disease severity was determined according to the WHO clinical progression scale. Serum N antigen levels were measured with a chemiluminescent assay (CLIA) and the Single Molecular Array (Simoa) assay. Viremia thresholds for severity were determined and proposed. In severe patients, the peak antigen response was observed 7 days after the onset of symptoms, followed by a decline. No real peak response was observed in non-severe patients. Severity thresholds for the Simoa and the CLIA provided positive likelihood ratios of 30.0 and 10.9 for the timeframe between day 2 and day 14, respectively. Sensitive detection of N antigens in serum may thus provide a valuable new marker for COVID-19 diagnosis and evaluation of disease severity. When assessed during the first 2 weeks since the onset of symptoms, it may help in identifying patients at risk of developing severe COVID-19 to optimize better intensive care utilization.