Archibong Archibong-Eso

Dr. Archibong Archibong-Eso

University of Birmingham, Birmingham, UK
orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Journal of Petroleum Science and Engineering
Verified
Journal Article
Closed access
YBYahaya Baba
Yahaya Baba
Aliyu M. AliyuAliyu M. Aliyu
Aliyu M. Aliyu
Archibong Archibong-EsoArchibong Archibong-Eso
Archibong Archibong-Eso
Mukhtar AbdulkadirMukhtar Abdulkadir
Mukhtar Abdulkadir
LLLiyun Lao
Liyun Lao
HYHoi Yeung
Hoi Yeung

1 July 2017 in Experimental Thermal and Fluid Science
Verified
Journal Article
Open access
Aliyu M. AliyuAliyu M. Aliyu
Aliyu M. Aliyu
AAAlmabrok A. Almabrok
Almabrok A. Almabrok
YBYahaya Baba
Yahaya Baba
Archibong Archibong-EsoArchibong Archibong-Eso
Archibong Archibong-Eso
LLLiyun Lao
Liyun Lao
KKKyung Chun Kim
Kyung Chun Kim
The entrained droplet fraction is an important parameter in annular two-phase flow, as its correlations are key inputs in flow simulation codes for the prediction of pressure drop and critical heat flux or dryout. Investigators have stressed the importance of extending the validity range of current correlations so that more conditions are covered. This could be achieved for example by including fluids with higher viscosities, a wider range of operating pressures, and increase in the size of pipes used for experiments (most of the data in the literature are from pipes of 50 mm diameter and below). In attempt to improve the latter, experiments were conducted in a 101.6 mm gas–liquid flow loop at Cranfield University’s Oil and Gas Engineering Laboratory and data on the fraction of droplets were collected in the annular flow regime by measuring the film velocity, from which the droplet fraction was calculated. Comparison of the film velocity by this method and by a mass balance showed close agreement. A capacitance Wire Mesh Sensor was used for flow visualisation in order to distinguish between annular and churn flow. In order to arrive at an improved correlation, over 1300 data points were gathered from other published works. These include air–water studies where large pipes of up to 127 mm in diameter were used. The others were from small-diameter pipes and for refrigerant, steam–water, air–water, and air–glycerine flows. Since in the annular regime, the gas flow entrains liquid droplets into the core, their presence alters the properties of the gas core. Therefore, accurate predictions are pivotal for the energy efficient design and operation of facilities in the petroleum and nuclear power industry. The correlation obtained here showed good agreement with the collected databank

1 March 2019 in Chemical Engineering Research and Design
Verified
Journal Article
Open access
OFOlawale T. Fajemidupe
Olawale T. Fajemidupe
Aliyu M. AliyuAliyu M. Aliyu
Aliyu M. Aliyu
YBYahaya Baba
Yahaya Baba
Archibong Archibong-EsoArchibong Archibong-Eso
Archibong Archibong-Eso
HYHoi Yeung
Hoi Yeung

1 April 2018 in Journal of Petroleum Science and Engineering
Verified
Journal Article
Closed access
Archibong Archibong-EsoArchibong Archibong-Eso
Archibong Archibong-Eso
YBYahaya Baba
Yahaya Baba
Aliyu M. AliyuAliyu M. Aliyu
Aliyu M. Aliyu
YZY. Zhao
Y. Zhao
WYW. Yan
W. Yan
HYH. Yeung
H. Yeung

1 April 2017 in Flow Measurement and Instrumentation
Verified
Journal Article
Closed access
YBYahaya Baba
Yahaya Baba
Archibong Archibong-EsoArchibong Archibong-Eso
Archibong Archibong-Eso
Aliyu M. AliyuAliyu M. Aliyu
Aliyu M. Aliyu
AAAbdulhaqq I. Ameen
Abdulhaqq I. Ameen

1 May 2013 in Chemical Engineering Science
Verified
Journal Article
Closed access
YZY. Zhao
Y. Zhao
HYH. Yeung
H. Yeung
EZE.E. Zorgani
E.E. Zorgani
Archibong Archibong-EsoArchibong Archibong-Eso
Archibong Archibong-Eso
LLLiyun Lao
Liyun Lao