Among the advanced oxidation processes (AOPs), the Fenton reaction has attracted much attention in recent years for the treatment of water and wastewater. This review provides insight into a particular variant of the process, where soluble Fe(II) salts are replaced by zero-valent iron (ZVI), and hydrogen peroxide (H2O2) is replaced by persulfate (S2O82−). Heterogeneous Fenton with ZVI has the advantage of minimizing a major problem found with homogeneous Fenton. Indeed, the precipitation of Fe(III) at pH > 4 interferes with the recycling of Fe species and inhibits oxidation in homogeneous Fenton; in contrast, suspended ZVI as iron source is less sensitive to the increase of pH. Moreover, persulfate favors the production of sulfate radicals (SO4•−) that are more selective towards pollutant degradation, compared to the hydroxyl radicals (•OH) produced in classic, H2O2-based Fenton. Higher selectivity means that degradation of SO4•−-reactive contaminants is less affected by interfering agents typically found in wastewater; however, the ability of SO4•− to oxidize H2O/OH− to •OH makes it difficult to obtain conditions where SO4•− is the only reactive species. Research results have shown that ZVI-Fenton with persulfate works best at acidic pH, but it is often possible to get reasonable degradation at pH values that are not too far from neutrality. Moreover, inorganic ions that are very common in water and wastewater (Cl−, HCO3−, CO32−, NO3−, NO2−) can sometimes inhibit degradation by scavenging SO4•− and/or •OH, but in other cases they even enhance the process. Therefore, ZVI-Fenton with persulfate might perform unexpectedly well in some saline waters, although the possible formation of harmful by-products upon oxidation of the anions cannot be ruled out.
Metals in wine occur at the mg l-1 level or less and, though not directly related to the taste of the final product, their content should be determined because excess is undesirable, and in some cases prohibited, due to potential toxicity. Lead content in wine, for example, is restricted in several states by legislation to guarantee consumer health protection. Of several methods for metal determination, techniques of atomic spectroscopy are the most sensitive and rapid. Most of the elements present in wine can be determined with these techniques, at concentrations ranging from the mg l-1 to the μg l-1 level. Here, inductively coupled plasma-atomic emission spectrometry (ICP-AES), flame atomic absorption spectrometry (flame-AAS) and graphite furnace-atomic absorption spectrometry (GF-AAS) are compared for their characteristics as employed in metal determination in wine.
Three samples of SBA‐15 functionalised with –(CH2)3COOH groups have been prepared by co‐condensation, starting from solutions of TEOS and 4‐(triethoxysilyl)butyronitrile, acting as –(CH2)3COOH precursor, of different molar compositions. Materials were characterised by X‐ray diffraction, nitrogen adsorption, and FT‐IR spectroscopy. The pKa and the acidic capacity were measured for all samples by potentiometric titration. The acidic capacity increases with increasing amount of –COOH precursor in the synthesis mixture only up to 10% molar of total alkoxysilane. The value for the pKa (4.75) is independent of the acidic capacity of the material. The sample prepared starting from an amount of –COOH precursor equal to 10% molar of total alkoxysilane was chosen to test selective interactions with heavy metals of environmental importance (Ag+, Cd2+, Fe3+, Cu2+, Zn2+) at different pH values and ionic strengths. The significant and selective adsorption exhibited by the material has been exploited in a preliminary cation‐exchange chromatographic application showing the possibility of eluting the metal ions at different retention times.
1 June 2001 in TrAC Trends in Analytical Chemistry