Thérèse Schunck

Dr. Thérèse Schunck

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 September 2020 in Shock Waves
Verified
Journal Article
Closed access
PDF file
TSThérèse Schunck
Thérèse Schunck
MBM. Bastide
M. Bastide
DED. Eckenfels
D. Eckenfels
JLJ.-F. Legendre
J.-F. Legendre

7 July 2021 in SN Applied Sciences
Verified
Journal Article
Open access
PDF file
TSThérèse Schunck
Thérèse Schunck
DED. Eckenfels
D. Eckenfels
This work is set in the context of blast mitigation based on geometric means, namely perforated metallic plates or grids. When a shock wave passes through a perforated plate, the flow field is modified, and new shock waves are created, as well as regions of vortices and turbulence in which the energy of the wave can be dissipated. In this study, an explosive driven shock tube (EDST) was used to visualize the interaction of a blast wave with perforated plates or with a piece of cast metallic foam. Additionally, the overpressure and the impulse of the reflected blast wave on a wall located downstream were assessed. The use of an EDST allowed the evaluation of the mitigation capacity under a high dynamic loading. Several combinations of perforated plates were tested, varying the geometry and the number of plates, as well as switching between two different spacings. When the shock wave collided with a plate, we observed that part of the incident shock wave was reflected by the plate, while the remaining wave was transmitted through it. Downstream of the plate, both the overpressure and the impulse were reduced, this effect being more prominent as the porosity of the plates decreased. When two plates were placed as obstacles, this phenomenon of reflection/transmission was repeated twice consecutively, further reducing the downstream reflected overpressure and impulse. An array of three plates or a piece of metallic foam were even more effective in mitigating the blast wave. Varying the distance between two or three plates had no effect on blast mitigation.

16 July 2021 in Materials
Verified
Journal Article
Open access
LBLudovic Blanc
Ludovic Blanc
TSThérèse Schunck
Thérèse Schunck
DEDominique Eckenfels
Dominique Eckenfels
In the following work, sacrificial claddings filled with different brittle materials were investigated, from concrete foam to granular media. They were subjected to blast loading using an explosive driven shock tube, while a sensor measures the load transmission and a high speed camera records the compression of the core. From a macroscopic point of view, concrete foam and granular media can act efficiently as a crushable core but differs greatly in terms of energy dissipation mechanisms. To compare them, granular media was at first treated as a cellular material, and different key parameters (plateau stress, densification strain) were computed using the energy absorption efficiency methodology. The presented tests results, coupled with observation in literature, allow a better understanding on the crushing process of a granular media. In particular, granular media tend to work as a core even for low intensity load, contrary to more classical crushable core.

26 May 2021 in Shock Waves
Verified
Journal Article
Closed access
PDF file
TSThérèse Schunck
Thérèse Schunck
MBM. Bastide
M. Bastide
DED. Eckenfels
D. Eckenfels
JLJ. F. Legendre
J. F. Legendre

24 May 2010 in Journal of Psychopharmacology
Verified
Journal Article
Closed access
PDF file
TSThérèse Schunck
Thérèse Schunck
AMAlexandre Mathis
Alexandre Mathis
GEGilles Erb
Gilles Erb
INIzzie Jacques NAMER
Izzie Jacques NAMER
YHYann Hode
Yann Hode
RLRémy Luthringer
Rémy Luthringer
Benzodiazepine effects on cholecystokinin tetrapeptide (CCK-4)-induced panic attack (PA) in humans are incompletely characterized, in particular on the neurofunctional level. This work explores the effects of lorazepam on brain activity and behavioral and physiological symptoms related to CCK-4-induced PA in healthy volunteers. Twenty-one male volunteers received 1 mg of lorazepam or placebo orally, 2 hours before an injection of 0.9% saline solution followed by 50 µg of CCK-4 during functional magnetic resonance imaging (fMRI) and heart rate recording. Panic attacks were defined using the panic symptom scale (PSS). In addition, the Y1-STAI (state anxiety) and the Bond & Lader Visual Analogue Scale (VAS) were used. Eleven subjects were classified as panickers. CCK-4 induced behavioral anxiety and cardiovascular effects along with cerebral activation in anxiety-related brain regions. Overall, lorazepam did not significantly modify the anxiogenic and cardiovascular effects of CCK-4. Regarding CCK-4-induced brain activation, lorazepam did not reduce activity in the insulae and cingulate gyrus of panickers. One milligram of lorazepam was not sufficient to reverse strong panicogenic effects, but decreased brain activity in the case of mild anxiety.

4 September 2014 in Electromagnetic Biology and Medicine
Verified
Journal Article
Closed access
TSThérèse Schunck
Thérèse Schunck
FBFrançois Bieth
François Bieth
SPSylvain Pinguet
Sylvain Pinguet
PDPhilippe Delmote
Philippe Delmote
Systems emitting ultra-wideband high power microwave (HP/UWB) pulses are developed for military and civilian applications. HP/UWB pulses typically have durations on the order of nanoseconds, rise times of picoseconds and amplitudes around 100kVm(-1). This article reviews current research on biological effects from HP/UWB exposure. The different references were classified according to endpoints (cardiovascular system, central nervous system, behavior, genotoxicity, teratology...). The article also reviews the aspects of mechanisms of interactions and tissue damage as well as the numerical work that has been done for studying HP/UWB pulse propagation and pulse energy deposition inside biological tissues. The mechanisms proposed are the molecular conformation change, the modification of chemical reaction rates, membrane excitation and breakdown and direct electrical forces on cells or cell constituents, and the energy deposition. As regards the penetration of biological matter and the deposited energy, mainly computations were published. They have shown that the EM field inside the biological matter is strongly modified compared to the incident EM field and that the energy absorption for HP/UWB pulses occurs in the same way as for continuous waves. However, the energy carried by a HP/UWB pulse is very low and the deposited energy is low. The number of published studies dealing with the biological effects is small and only a few pointed out slight effects. It should be further noted that the animal populations used in the studies were not always large, the statistical analyses not always relevant and the teams involved in this research rather limited in number.