The behaviour of reinforced concrete frames with masonry wall infills is influenced a lot by the stiffness and strength difference between the frame and the infill, causing early detrimental damage to the infill or to the critical concrete columns. The paper reports the results from shake table seismic tests on a full-scale reinforced concrete (RC) frame building with modified hollow clay block (orthoblock brick) infill walls, within INMASPOL SERA Horizon 2020 project. The building received innovative resilient protection using Polyurethane Flexible Joints (PUFJs) made of polyurethane resin (PU), applied at the frame-infill interface in different schemes. Further, PUs were used for bonding of glass fibre grids to the weak masonry substrate to form Fibre Reinforced Polyurethanes (FRPUs) as an emergency repair intervention. The test results showed enhancement in the in-plane and out-of-plane infill performance under seismic excitations. The results confirmed remarkable delay of significant infill damages at very high RC frame inter-story drifts as a consequence of the use of PUFJs. Further, the PUFJ protection enabled the resilient repair of the infill even after very high inter-story drift of the structure up to 3.7%. The applied glass FRPU system efficiently protected the damaged infills against collapse under out-of-plane excitation while they restored large part of their in-plane stiffness.
This study focused on characteristic cases of recently tested real-scale RC framed wall infilled structures with innovative seismic protection through polyurethane joints (PUFJ) or polyurethane-impregnated fiber grids (FRPU). The frames revealed a highly ductile response while preventing infill collapse. Herein, suitable 3D pseudo-dynamic FE models were developed in order to reproduce the experimental results. The advanced Explicit Dynamics framework may help reveal the unique features of the considered interventions. Externally applied double-sided FRPU jackets on OrthoBlock infills may maintain an adequate bond with the surrounding RC frame as well as with the brick infill substrate at up to a 3.6% drift. In a weak four-column RC structure, the OrthoBlock infills with PUFJ seismic joints may increase the initial stiffness remarkably, increase the base shear by three times (compared with the bare structure) and maintain a high horizontal drift of 3.7%. After this phase, the structure may receive FRPU retrofitting, reveal the redistribution of stress over broad infill regions, including predamaged parts, and still develop a higher initial stiffness and base shear (compared with the bare RC). The realization of a desirable ductile behavior of infilled frames through PUFJ of only 20 mm thickness, as well as through FRPU jacketing, may remarkably broaden the alternatives in seismic protection against the collapse of structures.
The global rapid urbanization intensifies environmental challenges related to climate change, such as air pollution and the urban heat island (UHI) effect in built environments. The need to optimize nature-based solutions (NBSs) is imperative to mitigate climate change and adapt to extreme weather phenomena. Against this background, this review offers an analysis regarding the integration of vertical greenery systems (VGSs) into urban environments so as to capitalize on their environmental, social, and economic benefits. Key aspects of the review include the positive role of VGSs in UHI mitigation, air quality improvement, stormwater management, and biodiversity enhancement, while examining social aspects (i.e., improved well-being and mental health, noise reduction, and urban built aesthetics). Finally, parameters related to economic benefits and energy efficiency are assessed. The submission further analyses the significant challenges that VGSs face, such as high maintenance costs, structural risks, plant health issues, fire hazards, and other limitations (legislative and technical). The crucial need for interdisciplinary collaborations among urban planners, architects, environmental engineers, and stakeholders is highlighted, in order to successfully integrate VGSs into urban buildings. Thus, this paper aims to identify key strategies for optimizing VGSs’ implementation and provide valuable insights for policymakers and researchers aiming to enhance urban sustainability through vertical greening.
This current review examines modeling approaches for renovating reinforced concrete (RC) buildings for vertical forest (VF) application, taking into account structural retrofitting, energy systems, forestry integration, and occupant comfort. The study assesses research conducted with an advanced 3D finite element analysis and the use of retrofitting modeling techniques, including textile-reinforced mortar (TRM), fiber-reinforced polymer (FRP), seismic joints, and green concrete applications. The energy system modeling methods are reviewed, taking into account the complexity of incorporating vegetation and seasonal variations. During forestry integration, three main design parameters are identified, namely, root systems, trunks, and crowns, for their critical role in the structural stability and optimal environmental performance. The comfort models are identified evolving from static to adaptive models incorporating thermal, acoustic, visual and air quality parameters. The current review consists of more than one hundred studies indicating that the integration of natural systems to buildings requires a multidimensional and multidisciplinary approach with sophisticated systems. The findings of this review provide the basis for implementing VF models to RC buildings, while highlighting areas requiring further research and validation.
This study examines Phase B of the GREENERGY project focusing on the seismic performance and structural health monitoring of a renovated single-story RC frame with brick masonry infills that received significant strategic structural interventions. The columns were confined with basalt fiber ropes (FR, 4 mm thickness, two layers) in critical regions, the vertical interfaces between infill and concrete were filled with polyurethane PM forming PUFJ (PolyUrethane Flexible Joints), and glass fiber mesh embedded in polyurethane PS was applied as FRPU (Fiber Reinforced PolyUrethane) jacket on the infills. Further, greenery renovations included the attachment of five double-stack concrete planters (each weighing 153 kg) with different support-anchoring configurations and of eight steel frame constructions (40 kg/m2) simulating vertical living walls (VLW) with eight different connection methods. The specimen was subjected to progressively increasing earthquake excitation based on the Thessaloniki 1978 earthquake record with peak ground acceleration ranging from EQ0.07 g to EQ1.40 g. Comprehensive instrumentation included twelve accelerometers, eight draw wire sensors, twenty-two strain gauges, and a network of sixty-one PZTs utilizing the EMI (Electromechanical Impedance) technique. Results demonstrated that the structure sustained extremely high displacement drift levels of 2.62% at EQ1.40 g while maintaining structural integrity and avoiding collapse. The PUFJ and FRPU systems maintained their integrity throughout all excitations, with limited FRPU fracture only locally at extreme crushing zones of two opposite bottom bricks. Columns’ longitudinal reinforcement entered yielding and strain hardening at top and bottom critical regions provided the FR confinement. VLW frames exhibited equally remarkably resilient performance, avoiding collapse despite local anchor degradation in some investigated cases. The planter performance varied significantly, yet avoiding overturning in all cases. Steel rod anchored planter demonstrated superior performance while simply supported configurations on polyurethane pads exhibited significant rocking and base sliding displacement of ±4 cm at maximum intensity. PZT structural health monitoring (SHM) sensors successfully tracked damage progression. RMSD indices of PZT recordings provided quantifiable damage assessment. Elevated RMSD values corresponded well to visually observed local damages while lower RMSD values in columns 1 and 2 compared with columns 3 and 4 suggested that basalt rope wrapping together with PUFJ and FRPU jacketed infills in two directions could restrict concrete core disintegration more effectively. The experiments validate the advanced structural interventions and vertical forest renovations, ensuring human life protection during successive extreme EQ excitations of deficient existing building stock.
The European building stock is aging and needs renovation. Holistic renovation approaches, including Vertical Forest (VF) systems, are emerging as sustainable alternatives to demolition and reconstruction. This paper reviews and defines missing reliable damage and hazard intensity measures for the holistic renovation of existing reinforced concrete (RC) buildings with VF systems. Based on an extensive literature review and preliminary studies, including empirical multiparametric system evaluation assessments, Monte Carlo simulations, and System-Theoretic Process Analysis (STPA), combined structural, non-structural, vegetation, and human comfort components are examined. Key damage indicators are identified, including interstory drift ratio, residual deformation, concrete and reinforcement strains/stresses, and energy dissipation, and their applicability to VF-integrated structures are evaluated. Green modifications are found to have higher risk profiles than traditional RC buildings (mean scores from Monte Carlo method: 9.72/15–11.41/15 vs. 9.47/15), with moisture management and structural integrity as critical concerns. The paper advances the understanding of hazard intensity measures for seismic, wind, and rainfall impacts. The importance of AI-driven vegetation monitoring systems with 80–99% detection accuracy is highlighted. It is concluded that successful VF renovation requires specialized design codes, integrated monitoring systems, standardized maintenance protocols, and enhanced control systems to ensure structural stability, environmental efficiency, and occupant safety.