Carlos-Antonio Domínguez-Torres

Dr. Carlos-Antonio Domínguez-Torres

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Applied Thermal Engineering
Verified
Journal Article
Closed access
CDCarlos-Antonio Domínguez-Torres
Carlos-Antonio Domínguez-Torres
RSRafael Suárez
Rafael Suárez
Angel Leon RodriguezAngel Leon Rodriguez
Angel Leon Rodriguez
ADANTONIO Domínguez-Delgado
ANTONIO Domínguez-Delgado

8 August 2024 in Building Simulation
Verified
Journal Article
Open access
PDF file
CDCarlos-Antonio Domínguez-Torres
Carlos-Antonio Domínguez-Torres
ADAntonio Domínguez-Delgado
Antonio Domínguez-Delgado
Radiative cooling has proven to be a useful tool to address the problems of lack of comfort and excessive energy consumption in situations of high temperatures, overheating and heat waves. Likewise, incorporating courtyards in warm climate zones has been found to be highly beneficial in addressing similar challenges. Hence, there is interest in analyzing the combined effects of both: radiative cooling and courtyards. This paper presents an analysis of the impact of the application of radiative cooling on a courtyard using a comprehensive simulation approach that includes a CFD model for the thermodynamic airflow in the adjacent roofs and inside the courtyard, equations for the transient heat conduction through roofs, walls and courtyard slabs, and a hybrid raytracing-radiosity model for the evaluation of the solar radiation reaching the building surfaces and its reflections, both of specular and diffuse origin, and for the calculation of the thermal radiation exchange, especially with the sky. The results show that in the hot season, the courtyard with radiative cooling always provides lower temperatures than the initial courtyard does, with a temperature range of 18.33 °C to 33.78 °C, compared to a range of 19.32 °C to 38.00 °C in the initial courtyard, and producing a greater difference with outdoor temperatures that can reach 12 °C versus 8 °C for the reference case. In addition, it was found that the courtyard with radiative cooling is able to significantly reduce the observed nighttime overheating by providing lower temperatures than the outdoor temperatures in the 50% of the nights studied. It was also found that the thermal loads to achieve indoor thermal comfort in the spaces adjacent to the courtyard were reduced by 63.46% to 69.85%.

5 January 2022 in Mathematics
Verified
Journal Article
Open access
PDF file
CDCarlos-Antonio Domínguez-Torres
Carlos-Antonio Domínguez-Torres
Angel Leon RodriguezAngel Leon Rodriguez
Angel Leon Rodriguez
Rafael  SuárezRafael Suárez
Rafael Suárez
ADANTONIO Domínguez-Delgado
ANTONIO Domínguez-Delgado
In recent years, there has been growing concern regarding energy efficiency in the building sector with energy requirements increasing worldwide and now responsible for about 40% of final energy consumption in Europe. Previous research has shown that ventilated façades help to reduce energy use when cooling buildings in hot and temperate climates. Of the different ventilated façade configurations reported in the literature, the configuration of ventilated façade with window rarely has been studied, and its 3D thermodynamic behavior is deserving of further analysis and modeling. This paper examines the thermal behavior of an opaque ventilated façade with a window, in experimentally and numerical terms and its impact in energy savings to get indoor comfort. Field measurements were conducted during the winter, spring and summer seasons of 2021 using outdoor full scale test cells located in Seville (southern Spain). The modeling of the ventilated façade was carried out using a three-dimensional approach taking into account the 3D behavior of the air flow in the air cavity due to the presence of the window. The validation and comparison process using experimental data showed that the proposed model provided good results from quantitative and qualitative point of view. The reduction of the heat flux was assessed by comparing the energy performance of a ventilated façade with that of an unventilated façade. Both experimental and numerical results showed that the ventilated façade provided a reduction in annual total energy consumption when compared to the unventilated façade, being compensated the winter energy penalization by the summer energy savings. This reduction is about 21% for the whole typical climatic year showing the ability of the opaque ventilated façade studied to reduce energy consumption to insure indoor comfort, making its suitable for use in retrofitting the energy-obsolete building stock built in Spain in the middle decades of the 20 century.

27 September 2021 in Sustainability
Verified
Journal Article
Open access
PDF file
CDCarlos-Antonio Domínguez-Torres
Carlos-Antonio Domínguez-Torres
HDHelena Domínguez-Torres
Helena Domínguez-Torres
ADANTONIO Domínguez-Delgado
ANTONIO Domínguez-Delgado
Social housing built in the middle of the last century in Spain suffers from poor thermal insulation conditions that cause situations of discomfort and energy poverty. For this reason, the energetic refurbishment of the envelope of this social building stock is necessary to overcome these situations and reduce energy consumption aimed at achieving interior comfort for its occupants. The goal of this work is to optimize a constructive solution that combines cool roof techniques with the use of thermal insulation applied to the refurbishment of the roof of buildings belonging to a quarter of social housing in Seville, Spain. The optimization analysis is based on the computation of the energy performance of the roofs when the energy retrofitting measure is applied, considering a variety of combinations of solar reflective coatings and insulation layer thickness, performing a dynamic analysis that accounts for the aging effect of the cool coats on the monthly roof energy performance and on the economic balance for the whole life cycle (LC) span. Economic and energy optimization analysis show that a suitable combination of cool roof emissivity and insulation layer thickness produces significant savings in the operational energy and in the economic profitability of the proposed retrofitting measure: the optimum combination obtained provides for the entire life cycle timespan an energy savings of 5.71 GJ/m2 and a cost savings equivalent to the 63.1% of the total costs when compared to the non-refurbished roof. The application of a time-dependent pattern for the changes on time produced by the aging effect on the cool roof emissivity, and its effects on the optimization of the combination of cool roof and insulation layer, can be considered novel in literature, both from an energy and an economic point of view.

2 April 2024 in Renewable Energy
Verified
Journal Article
Open access
CDCarlos-Antonio Domínguez-Torres
Carlos-Antonio Domínguez-Torres
Rafael  SuárezRafael Suárez
Rafael Suárez
Angel Leon RodriguezAngel Leon Rodriguez
Angel Leon Rodriguez
ADANTONIO Domínguez-Delgado
ANTONIO Domínguez-Delgado

28 December 2023 in Buildings
Verified
Journal Article
Open access
PDF file
CDCarlos-Antonio Domínguez-Torres
Carlos-Antonio Domínguez-Torres
HDHelena Domínguez-Torres
Helena Domínguez-Torres
MVMiguel Hernández Valencia
Miguel Hernández Valencia
JRJorge Roa-Fernández
Jorge Roa-Fernández
RHRafael Herrera-Limones
Rafael Herrera-Limones
1960s Europe saw a large number of residential neighborhoods built to house those migrating from the countryside. Today, more than 50 years later, these neighborhoods suffer high levels of functional, social, and technical obsolescence. In response to this, the University of Seville developed the Aura Strategy as an intervention methodology to find global solutions to issues in outdated neighborhoods. To provide visibility to this aspect of the Aura Strategy, the retrofit proposal presented in this article provides a solution to improve the roofing of buildings in a case study neighborhood (Polígono de San Pablo, Seville) and an analysis of the results in terms of energy and financial savings for local residents. The results show that for a population of roughly 18,000 (in 2018), net savings, including energy and retrofitting costs, ranging from nearly €6.5 to over €8.6 million can be made over the 20-year life-cycle span. Likewise, the results obtained on the reduction of thermal loads indicate a 72% decrease in energy consumption, equivalent to a saving of close to 4500 tons of greenhouse gas emissions for the district and the entire life-cycle time period, with the consequent benefits on the impact on air quality and the fight against climate change.