Mohamad Dakroub

Dr. Mohamad Dakroub

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2023 in Journal of Current Glaucoma Practice
Verified
Journal Article
Open access
MDMohamad Dakroub
Mohamad Dakroub
RVRaoul Verma-Fuehring
Raoul Verma-Fuehring
ASAlicja Strzalkowska
Alicja Strzalkowska
JHJost Hillenkamp
Jost Hillenkamp
YYYousef Al Yousef
Yousef Al Yousef
NLNils Loewen
Nils Loewen
To compare ab interno trabeculectomy by trabecular meshwork (TM) excision to plasma-mediated ablation in primary open-angle glaucoma (POAG) patients. Retrospectively collected data of TrabEx+ (TEx) (n = 56) and Trabectome (T) (n = 99) patients were compared by coarsened exact matching to reduce confounding and matched based on baseline intraocular pressure (IOP) and age. The primary outcomes were IOP and the number of glaucoma medications. Complications and the need for additional glaucoma surgery were assessed. Patients were followed for up to 1 year. A total of 53 TEx could be matched to T. Baseline IOP was 16.5 ± 4.6 mm Hg in both; age was 73.7 ± 8.8 and 71.5 ± 9.9 years in TEx and T, respectively. TEx was taking more medications than T (p < 0.001). IOP was reduced to 14.8 ± 4.3 in TEx and to 13.4 ± 3.4 in T at 6 months, and to 14.9 ± 6.0 (p = 0.13) in TEx and to 14.1 ± 3.8 mm Hg (all p < 0.05) in T at 12 months. Medications were reduced at both 6 and 12 months (p < 0.05). No differences were seen between TEx and T at 6 and 12 months. In TEx, only one serious complication occurred, and two patients required further glaucoma surgery. Although both groups had a baseline IOP considered low for ab interno trabeculectomy, IOP and medications were reduced further at 6 and 12 months. IOP reduction did not reach significance in TEx at 12 months. The intergroup comparison did not reveal any significant differences. Both had a low complication rate. This study investigated subtle differences between a plasma-ablative device, the T, and an excisional device, the TEx, by applying coarsened exact matching. IOP and medications were reduced in both groups at 6 and 12 months, although IOP reduction did not reach significance in TEx at 12 months. The intergroup comparison did not reveal any significant differences, with both devices having a low complication rate. Dakroub M, Verma-Fuehring R, Strzalkowska A, et al. Coarsened Exact Matching of Excisional to Plasma-ablative Ab Interno Trabeculectomy. J Curr Glaucoma Pract 2023;17(1):9-14.

20 September 2021 in Preprints.org
Verified
Preprint
Open access
RVRaoul Verma-Fuehring
Raoul Verma-Fuehring
MDMohamad Dakroub
Mohamad Dakroub
HHHong Han
Hong Han
JHJost Hillenkamp
Jost Hillenkamp
NLNils Loewen
Nils Loewen
Purpose: To investigate trabeculopuncture (TP) for predicting the outcome of ab interno trabeculectomy (AIT). AIT is an effective, low-risk procedure for open angle glaucoma. Despite widespread utilization, it fails in patients with an unidentified distal outflow resistance. Methods: We bisected 81 enucleated porcine eyes and perfused them for 72 hours. They were assigned to two groups: trial (n=42) and control (n=39). Intraocular pressure (IOP) was measured continuously. At 24 hours, four YAG-laser trabeculopunctures on the nasal trabecular meshwork were performed, followed by a 180° AIT at the same site at 48 hours. Eyes were divided into TP and AIT responders and non-responders; the proportion of TP responders between both AIT groups was compared. Results: Both post-TP and post-AIT IOPs were lower than baseline IOP (p=0.015 and p<0.01, respectively). The success rates of TP and AIT were 69% and 85.7%, respectively. The proportion of TP responders among AIT responders was greater than that of AIT non-responders (p20% IOP decrease) of 180° AIT in porcine eyes.

1 July 2021 in F1000Research
Verified
Journal Article
Open access
PDF file
RVRaoul Verma-Fuehring
Raoul Verma-Fuehring
MDMohamad Dakroub
Mohamad Dakroub
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
HHHong Han
Hong Han
NLNils Loewen
Nils Loewen
Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork ablation by freeze-thaw would be accompanied by a similarly large change in the distal outflow pattern. Methods: Two-dye (fluorescein and Texas red) reperfusion canalograms were used to compare the outflow time before and after two -80°C cycles of freeze-thaw. We assigned 28 freshly enucleated porcine eyes to four groups: perfused anterior segment dye controls (ACO, n = 6), perfused whole eye dye controls (WCO, n = 6), freeze-thaw treated anterior segment cultures (AFT, n = 10), and freeze-thaw treated whole eyes (WFT, n = 6). Results: In control groups ACO and WCO, the two different dyes had similar filling times. In AFT, the outflow pattern and filling times were unchanged. In WFT, the temporal superior quadrant filled more slowly (p = 0.042) while all others remained unchanged. The qualitative appearance of distal outflow spaces was altered only in some eyes. Conclusions: Freeze-thaw cytoablation caused neither loss nor leakage of distal outflow structures. Surprisingly, the loss of an intact trabecular meshwork over the entire circumference did not result in a general acceleration of quadrant outflow times. The results validate freeze-thawing as a method to generate an extracellular matrix without major structural changes.

9 February 2022 in F1000Research
Verified
Journal Article
Open access
PDF file
RVRaoul Verma-Fuehring
Raoul Verma-Fuehring
MDMohamad Dakroub
Mohamad Dakroub
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
HHHong Han
Hong Han
NLNils Loewen
Nils Loewen
Background: Porcine eyes have been widely used as ex vivo models in glaucoma research, as they share similar features with human eyes. Freeze-thawing is a non-invasive technique that has been used to obliterate living cells in anterior segment ex vivo cultures, to prepare them for further research such as cellular repopulation. This technique has previously been shown to reduce the intraocular pressure (IOP) in porcine eyes. The aim of this study was to investigate whether freeze-thaw cytoablation causes corresponding canalogram outflow changes in perfused anterior segment cultures (AFT) and whole porcine eyes (WFT). We hypothesized that the known IOP drop in AFT after trabecular meshwork ablation by freeze-thaw would be accompanied by a similarly large change in the distal outflow pattern. Methods: Two-dye (fluorescein and Texas red) reperfusion canalograms were used to compare the outflow time before and after two -80°C cycles of freeze-thaw. We assigned 28 freshly enucleated porcine eyes to four groups: perfused anterior segment dye controls (ACO, n = 6), perfused whole eye dye controls (WCO, n = 6), freeze-thaw treated anterior segment cultures (AFT, n = 10), and freeze-thaw treated whole eyes (WFT, n = 6). Results: In control groups ACO and WCO, the two different dyes had similar filling times. In AFT, the outflow pattern and filling times were unchanged. In WFT, the temporal superior quadrant filled more slowly (p = 0.042) while all others remained unchanged. The qualitative appearance of distal outflow spaces was altered only in some eyes. Conclusions: Freeze-thaw cytoablation caused neither loss nor leakage of distal outflow structures. Surprisingly, the loss of an intact trabecular meshwork over the entire circumference did not result in a general acceleration of quadrant outflow times. The results validate freeze-thawing as a method to generate an extracellular matrix without major structural changes.

14 September 2021 in Preprints.org
Verified
Preprint
Open access
MDMohamad Dakroub
Mohamad Dakroub
RVRaoul Verma-Fuehring
Raoul Verma-Fuehring
ASAlicja Strzalkowska
Alicja Strzalkowska
JHJost Hillenkamp
Jost Hillenkamp
YYYousef Al Yousef
Yousef Al Yousef
NLNils Loewen
Nils Loewen
Purpose: To compare ab interno trabeculectomy by trabecular meshwork excision to plasma-mediated ablation in primary open-angle glaucoma. Methods: Retrospectively collected data of TrabEx+ (TEx, n=56) and Trabectome (T, n=99) were compared by coarsened exact matching to reduce confounding and matched based on baseline IOP and age. Primary outcomes were IOP and number of glaucoma medications. Complications and need for additional glaucoma surgery were assessed. Patients were followed for up to one year. Results: 53 TEx could be matched to T. Baseline IOP was 16.5±4.6 mmHg in both; age was 73.7±8.8 and 71.5±9.9 years in TEx and T, respectively. TEx were taking more medications than T (p<0.001). IOP was reduced to 14.8±4.3 in TEx and to 13.4±3.4 in T at 6 months, and to 14.9±6.0 (p=0.13) in TEx and to 14.1±3.8 mmHg (all p<0.05) in T at 12 months. Medications were reduced at both 6 and 12 months (p< 0.05). No differences were seen between TEx and T at 6 and 12 months. In TEx, only one serious complication occurred, and two patients required further glaucoma surgery. Conclusion: Although both groups had a baseline IOP considered low for ab-interno trabeculectomy, IOP and medications were reduced further at 6 and 12 months. IOP reduction did not reach significance in TEx at 12 months. The inter-group comparison did not reveal any significant differences. Both had a low complication rate.

30 August 2021 in Preprints.org
Verified
Preprint
Open access
MDMohamad Dakroub
Mohamad Dakroub
RVRaoul Verma-Fuehring
Raoul Verma-Fuehring
VAVaia Agorastou
Vaia Agorastou
JSJulian Schön
Julian Schön
JHJost Hillenkamp
Jost Hillenkamp
NLNils Loewen
Nils Loewen
Purpose: To determine whether 24-hour IOP monitoring can be a predictor for glaucoma progression and to analyze the inter-eye relationship of IOP, perfusion and progression parameters. Methods: We extracted data from manually drawn IOP curves with HIOP-Reader, a software suite we developed. The relationship between measured IOPs and mean ocular perfusion pressures (MOPP) to retinal nerve fiber layer (RNFL) thickness was analyzed. We determined the ROC curves for peak IOP (Tmax), average IOP (Tavg), IOP variation (IOPvar) and historical IOP cut-off levels to detect glaucoma progression (rate of RNFL loss). Bivariate analysis was conducted to check for various inter-eye relationships. Results: 217 eyes were included. The average IOP was 14.8±3.5 mmHg, with a 24-hour variation of 5.2±2.9 mmHg. 52% of eyes with RNFL data showed disease progression. There was no significant difference in Tmax, Tavg and IOPvar between progressors and non-progressors (all p>0.05). Except for Tavg and the temporal RNFL, there was no correlation between disease progression in any quadrant, Tmax, Tavg and IOPvar. 24-hour and outpatient IOP variables had poor sensitivities and specificities in detecting disease progression. The correlation of inter-eye parameters was moderate; correlation with disease progression was weak. Conclusion: In line with our previous study, IOP data obtained during a single visit (outpatient or inpatient monitoring) make for a poor diagnostic tool, no matter the method deployed. Glaucoma progression and perfusion pressure in left and right eyes correlated weakly to moderately with each other.