Alicja Strzalkowska

Dr. Alicja Strzalkowska

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 June 2023 in Journal of Glaucoma
Verified
Journal Article
Open access
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
Esther M.  HoffmannEsther M. Hoffmann
Esther M. Hoffmann
NPNorbert Pfeiffer
Norbert Pfeiffer
ASAlexander K. Schuster
Alexander K. Schuster
Précis: After the open bleb revision following PreserFlo, the mean postoperative intraocular pressure (IOP) was lowered from 26.4 ± 9.9 mm Hg to 12.9 ± 5.6 mm Hg at 1 month and 15.9 ± 4.1 mm Hg at 12 months. Purpose: The purpose of this study was to evaluate the effectiveness and safety of an open bleb revision with mitomycin- C (MMC) for bleb fibrosis after PreserFlo MicroShunt implantation. Patients and Methods: We performed a retrospective analysis of 27 consecutive patients with bleb fibrosis after PreserFlo MicroShunt Implantation that underwent an open revision with MMC 0.2 mg/mL applied for 3 minutes at the Department of Ophthalmology of the Mainz, University Medical Center, Mainz, Germany. Demographic data, such as age, sex, glaucoma type, number of glaucoma medications, IOP before and after PreserFlo implantation and revision, complications, and reoperations within 12 months, were analyzed. Results: Twenty-seven patients (27 eyes) received an open revision after previous PreserFlo Microshunt implantation and consecutive bleb fibrosis. The mean preoperative IOP was 26.4 ± 9.9 mm Hg before revision, 7.0 ± 2.7 mm Hg ( P < 0.001) in the first week after the revision, and 15.9 ± 4.1 mm Hg at 12 months ( P = 0.02). Four patients needed IOP-lowering medication after 12 months. One patient had a positive Seidel test and needed a conjunctival suture. Four patients required a second procedure due to recurring bleb fibrosis. Conclusions: At 12 months, open revision with MMC for bleb fibrosis after failed PreserFlo implantation effectively and safely reduced IOP with a similar medication burden.

Verified
Journal Article
Open access
PDF file
ASAlicja Strzalkowska
Alicja Strzalkowska
NPNina Pirlich
Nina Pirlich
JSJulia V. Stingl
Julia V. Stingl
ASAlexander K. Schuster
Alexander K. Schuster
JRJasmin Rezapour
Jasmin Rezapour
Esther M.  HoffmannEsther M. Hoffmann
Esther M. Hoffmann
Objective: We aimed to compare intraocular pressure (IOP) measurements using iCare® PRO rebound tonometry (iCare) and Perkins applanation tonometry (Perkins) in childhood glaucoma subjects and healthy children and the influence of anaesthesia depth, age and corneal thickness. Material: Prospective clinical, case-control study of children who underwent an ophthalmologic examination under general anaesthesia according to our protocol. Children were 45.45 ± 29.76 months old (mean ± SD (standard deviation)). Of all children, 54.05% were female. IOP was taken three times (T1–T3), according to duration and the depth of anaesthesia. The order of measurement alternated, starting with iCare. Agreement between the device measurements was evaluated using Bland–Altman analysis. Results: 53 glaucoma subjects and 22 healthy controls. Glaucoma subjects: IOP measured with iCare was at T1: 27.2 (18.1–33.8), T2: 21.6 (14.8–30.6), T3: 20.4 mmHg (14.5–27.0) and Perkins 17.5 (12.0–23.0), 15.5 (10.5–20.5), 15.0 mmHg (10.5–21.0) (median ± IQR (interquartile range)). Healthy controls: IOP with iCare: T1: 13.3 (11.1–17.0), T2: 10.6 (8.1–12.4), T3: 9.6 mmHg (7.7–11.7) and Perkins 10.3 (8.0–12.0), 7.0 (5.5–10.5), 7.0 mmHg (5.5–8.5) (median ± IQR). The median IOP was statistically significantly higher with iCare than with Perkins (p < 0.001) in both groups. The mean difference (iCare and Perkins) was 6.0 ± 6.1 mmHg for T1–T3, 7.3 at T1, 6.0 at T2, 4.9 mmHg at T3. Conclusion: The IOP was the highest in glaucoma subjects and healthy children at T1 (under sedation), independently of the measurement method. iCare always leads to higher IOP compared to Perkins in glaucoma and healthy subjects, regardless of the duration of anesthesia.

25 October 2023 in Die Ophthalmologie
Verified
Journal Article
Closed access
PDF file
ASAlicja Strzalkowska
Alicja Strzalkowska
EHEsther M. Hoffmann
Esther M. Hoffmann
PSPiotr Strzalkowski
Piotr Strzalkowski
JSJulia V. Stingl
Julia V. Stingl
NPNorbert Pfeiffer
Norbert Pfeiffer
ASAlexander K. Schuster
Alexander K. Schuster

5 July 2023 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
JSJulia V. Stingl
Julia V. Stingl
NPNorbert Pfeiffer
Norbert Pfeiffer
ASAlexander K. Schuster
Alexander K. Schuster
Esther M.  HoffmannEsther M. Hoffmann
Esther M. Hoffmann
Purpose: To assess long-time results of primary surgical treatment in children with glaucoma after congenital cataract surgery. Methods: A retrospective study of 37 eyes from 35 children with glaucoma after congenital cataract surgery, who underwent surgery between 2011 and 2021 at the Childhood Glaucoma Center, University Medical Center Mainz, Germany. Only children, who received a primary glaucoma surgery in our clinic within the given time (n = 25) and had at least one-year follow-up (n = 21), were included in the further analysis. The mean follow-up time was 40.4±35.1 months. The primary outcome was the mean reduction in IOP (in mmHg) from baseline to follow-up visits after the surgery, measured with Perkins tonometry. Results: 8 patients (38%) were treated with probe trabeculotomy (probe TO), 6 (29%) with 360° catheter-assisted trabeculotomy (360° TO) and 7 (33%) with cyclodestructive procedures. IOP was significantly reduced after probe TO and 360° TO after 2 years, from 26.9 mmHg to 17.4 mmHg (p<0.01) and 25.2 mmHg to 14.1 mmHg (p<0.02), respectively. There was no significant IOP reduction after cyclodestructive procedures after 2 years. Both, probe TO and 360° TO led descriptively to eye drops reduction after 2 years, from 2.0 to 0.7 and 3.2 to 1.1. The reduction was not significant. Conclusions: In glaucoma after congenital cataract surgery, both trabeculotomy techniques, lead to good reduction of IOP after 2 years. There is a need for a prospective study with comparison to the use of glaucoma drainage implants.

4 June 2021 in F1000Research
Verified
Journal Article
Open access
PDF file
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
YYYousef Al Yousef
Yousef Al Yousef
JHJost Hillenkamp
Jost Hillenkamp
FGFranz Grehn
Franz Grehn
NLNils Loewen
Nils Loewen
Background: To compare two-year results of a filtering trabeculotomy (FTO) to conventional trabeculectomy (TE) in open-angle glaucoma by exact matching. Methods: 110 patients received an FTO and 86 a TE. FTO avoided the need for an iridectomy due to a preserved trabeculo-descemet window anterior to the scleral flap. TE employed a trabecular block excision and iridectomy. Mitomycin C was used in both. FTO and TE were exact matched by baseline intraocular pressure (IOP) and the number of glaucoma medications. Complete and qualified success (IOP ≤18 mmHg and IOP reduction ≥ 30%, with or without medication) were primary endpoints. IOP, visual acuity (BCVA), complications and intervention were secondary endpoints. Results: 44 FTO were exact matched to 44 TE. The IOP baseline in both groups was 22.5±4.7 mmHg on 3±0.9 medications. At 24 months, complete success was reached by 59% in FTO and 66% in TE, and qualified success by 59% in FTO and 71% in TE. In FTO, IOP was reduced to 12.4±4.3 mmHg at 12 months and 13.1±4.1 mmHg at 24 months. In TE, IOP was 11.3±2.2 mmHg at 12 months and 12.0±3.5 mmHg at 24 months. Medications could be reduced at 24 months to 0.6±1.3 in FTO and 0.2±0.5 in TE. There were no significant differences between the two groups in IOP, medications, complications or interventions at any point. Conclusion: Modifying aqueous flow through a limited trabeculotomy in FTO yielded clinical outcomes similar to traditional TE but allowed to avoid an iridectomy.

21 August 2025 in European Journal of Ophthalmology
Verified
Journal Article
Open access
ASAlicja Strzalkowska
Alicja Strzalkowska
PSPiotr Strzalkowski
Piotr Strzalkowski
LDLeon Daniello
Leon Daniello
EHEsther M Hoffmann
Esther M Hoffmann
NPNorbert Pfeiffer
Norbert Pfeiffer
ASAlexander K Schuster
Alexander K Schuster
Purpose: The aim of our study was to evaluate the outcome of trabeculectomy with respect to surgeon's experience and to explore additional contributing factors. Methods: This retrospective study was conducted analyzing consecutive single-surgeon cases from October 2019 to June 2022 receiving TE with mitomycin C. Eyes were categorized into five groups based on surgeon experience: E1 for the first 50 TEs, E2 for 51–100, E3 for 101–150, E4 for 151–200, E5 for 201–300. Complete success at one year was defined as an IOP <18 mmHg and 20%-IOP reduction without glaucoma eye drops and revision surgeries. Results: 300 eyes were included (mean age 68.8 ± 13.0 years, 58.3% female). 55.7% had primary open-angle glaucoma. The baseline IOP was 23.4 ± 8.7 mmHg with 3.0 ± 0.9 different antiglaucomatous medication. After 12 months, the complete success for E1 to E5, it was 83.0%, 86.7%, 87.4%, 75.3% and 79.1% ( p < 0.0001) with IOP 12.8 ± 6.1, 12.8 ± 6.3, 11.5 ± 4.6, 12.9 ± 6.5, 12.9 ± 4.7 mmHg while there was a higher number of NTG cases in E4 and E5 ( p = 0.04). Conclusions: Even a novice surgeon can achieve a good surgical outcome within the first 50 trabeculectomy under the guidance of an experienced surgeon. When comparing surgical results over time, it is important to incorporate case entity and severity.